Dear Customer,
Thank you for choosing a Hanna Instruments
Product.
HI 955501
Please read this instruction manual carefully
before using the instrument. This manual will
provide you with all the necessary information for the correct use of the instrument, as
Portable
PT100 Thermometer
well as a more precise idea of its versatility in
a wide range of applications.
This instrument is in compliance with the
directives EN 50081-1 and EN 50082-1.
This Instrument is in Compliance with the CE Directives
ISO 9000 Certified
Company since 1992
Untitled-9
ins
rum n
s
RANGE
PT100
THERMOMETER
HI 955501
-199.9°C to 199.9°C
-200°C to 850°C
RANGE:
OFF
ON
°C
1
2
3
3
PRELIMINARY EXAMINATION
Remove the instrument from the packing
material and examine it carefully to make
sure that no damage has occurred during
shipment. If noticeable damage is evident,
notify your Dealer.
HI 955501 comes supplied with:
• 9V battery
• instruction manual.
Note: Save all packing material until you
are sure that the instrument functions
correctly. All defective items must be
returned in their original packing.
GENERAL DESCRIPTION
HI 955501 HI 955501
HI 955501 allows temperature measurement
HI 955501 HI 955501
using interchangeable PT100 probes.
HH
II
955501955501
H
I
955501 allows temperature measurements
HH
II
955501955501
with two different resolutions: 0.1°C between
±199.9 and 1°C outside.
Standard features include low battery detection and self-explanatory symbols to remind
the user of the operating mode or condition.
1
4
FUNCTIONAL DESCRIPTION
AND SPECIFICATIONS
1. Liquid Crystal Display
2. ON/OFF Key
3. Range Key
Range-199.9 to 199.9°C
Resolution0.1°C (±199.9°C)
Accuracy for one year, excluding probe error
Low Range ±0.2°C & ±1 digit (-120 to 200°C)
High Range ±1°C & ±1 digit (-170 to 450°C)
Typical EMC±0.5°C
Deviation
ProbeHI 768 series (not included)
Battery Type9V
Life150 hours of continuous use
Environment 0 to 50°C (32 to 122°F)
Dimensions 143x80x38 mm(5.6x3.2x1.5")
Weight320 g (11.3 oz.)
-200 to 850°C
1°C (outside)
±1°C & ±1 digit (outside)
±1% F.S. & ±1 digit (outside)
2
95% RH
Untitled-9
5
OPERATIONAL GUIDE
INITIAL PREPARATION
Slide the battery cover off
the rear of your thermometer.
Remove the battery and unwrap it prior to connection to
the battery connector. Insert
the 9V battery and replace
the cover.
To switch on, press the ON/
OFF key on the front of the
unit.
If a temperature probe is
plugged in, the unit will display the temperature.
If not plugged in, the display
will show "-1.".
To switch your thermometer off, press the
ON/OFF key again.
MEASUREMENT RESOLUTION
When switched on, the instrument defaults
to the last selected resolution.
To change the resolution
press RANGE.
The instrument automatically
changes its resolution to 1
degree when it passes the
limit of the lower range
(±200°C).
3
9 VOLT BATTERY
Compartment
SLIDE OFF
ON
OFF
°C
RANGE
Battery
6
LOW BATTERY DETECTION
When the battery is low the
user is prompted by the appearance of the "V" symbol
to replace the battery.
DISPLAY CODE GUIDE
DisplayDescription
-1.The probe is not connected to the instrument or
the reading is out of range
VWeak battery, needs to be replaced
°CThe instrument is reading in the Centigrade
scale
CALIBRATION
All Hanna Instruments thermometers have
been accurately pre-calibrated at the factory.
It is generally recommended to have all
thermometers recalibrated at least once a
year.
For an accurate annual recalibration, contact your nearest Hanna Service Center.
4
V
Untitled-9
7
BATTERY REPLACEMENT
When the battery is low the
user is warned by the "V"
symbol on the instrument's
display. Replace the battery
immediately.
Battery replacement must only take place in
a non hazardous area using the battery types
specified in this instruction manual (see
page 7).
Remove the battery compartment cover on
the rear of the meter and replace the 9V
battery with a new one. Make sure the battery contact is tight before putting the cover
back.
9 VOLT BATTERY
8
SHOCKPROOF RUBBER BOOTS
These rubber boots are specially made to
prolong the life of your instruments and to
V
prevent damages due to accidental falls.
They measure 155 x 90 x 45 mm
(6.1x3.5x1.8") and are available in two different colors:
HI935BTY = orange colored
HI935BTB = blue colored.
Select the proper color according to your
preference.
°C
PT100
THERMOMETER
ON
OFF
RANGE:
-199.9 to 199.9°C
-200 to 850°C
RANGE
Battery
Compartment
SLIDE OFF
5
HI955501
6
Untitled-9
9
ACCESSORIES
PT 100 Probes
HI768AAir probe, with 1 m (3.3') cable
HI768LGeneral purpose liquid probe,
HI768PPenetration probe with 1 m
Other accessories:
BATT9/P9V battery (10 pcs)
BORGTSoft carrying case measuring
HI935BTYYellow rubber boot measuring
HI935BTBBlue rubber boot measuring
MANPT100R1 Instruction manual
with 1 m (3.3') cable
(3.3') cable
205mm
8.1"
100mm
3.9"
HI 768P
205mm
8.1"
100mm
3.9"
HI 768A
205mm
8.1"
100mm
3.9"
HI 768L
150x90x30mm
155 x 90 x 45 mm
155 x 90 x 45 mm
7
3mm
0.12"
3 mm
0.12"
3mm
0.12"
6mm
0.24"
10
WARRANTY
All Hanna Instruments meters are warranted
for two years against defects in workman-
ship and materials when used for their intended purpose and maintained according
to instructions.
The probes are warranted for a period of
six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are
not covered.
If service is required, contact the dealer
from whom you purchased the instrument. If
under warranty, report the model number,
date of purchase, serial number and the
nature of the failure. If the repair is not
covered by the warranty, you will be notified
of the charges incurred. If the instrument is
to be returned to Hanna Instruments, first
obtain a Returned Goods Authorization Number from the Customer Service department
and then send it with shipment costs prepaid. When shipping any instrument, make
sure it is properly packaged for complete
protection.
To validate your warranty, fill out and return
the enclosed warranty card within 14 days
from the date of purchase.
All rights are reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
Hanna Instruments reserves the right to
modify the design, construction and appearance of its products without advance notice.
8
Untitled-9
11
CE DECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY
We
Hanna Instruments Srl
V.le delle industrie 12
35010 Ronchi di Villafranca (PD)
ITALY
herewith certify that the thermometer
has been tested and found to be in compliance with the following regulations:
IEC 801-2 Electrostatic Discharge
IEC 801-3 RF Radiated
EN 55022Radiated, Class B
Date of Issue: 13-03-1996
HI 955501
D.Volpato - Engineering Manager
On behalf of
Hanna Instruments S.r.l.
12
Recommendations for Users
Before using this product, make sure that it is entirely suitable for the environment in which
it is used.
Operation of this instrument in residential area could cause unacceptable interferences to
radio and TV equipments, requiring the operator to take all necessary steps to correct
interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument's
EMC performance.
To avoid electrical shock, do not use this instrument when voltages at the measurement
surface exceed 24VAC or 60 VDC.
To avoid damages or burns, do not perform any measurement in microwave ovens.
9
MANPT100R1
05/96
Stay in Touch with the Manufacturer!
Loading...