Hanna Instruments HI 8014, HI 8915, HI 8314, HI 9214, HI 931000 Instruction Manual

...
Instruction Manual
HI 8014 - HI 8314 HI 8424 - HI 8915
HI 9214 - HI 931000
HI 9622
Portable
pH Meters
http://www.hannainst.com
These Instruments are in
Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the meter.
This manual will provide you with the necessary information for a correct use of the instrument, as well as a more precise idea of its versatility. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com.
These instruments are in compliance with the directives EN 50081-1 and EN 50082-1.
TABLE OF CONTENTSTABLE OF CONTENTS
TABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
PRELIMINARY EXAMINATION........................................................3
GENERAL DESCRIPTION ................................................................ 3
FUNCTIONAL DESCRIPTION HI 8014.............................................5
SPECIFICATIONS HI 8014 ............................................................6
FUNCTIONAL DESCRIPTION HI 8314.............................................7
SPECIFICATIONS HI 8314 ............................................................8
FUNCTIONAL DESCRIPTION HI 8915.............................................9
SPECIFICATIONS HI 8915 ..........................................................10
FUNCTIONAL DESCRIPTION HI 9214...........................................11
SPECIFICATIONS HI 9214 ..........................................................12
FUNCTIONAL DESCRIPTION HI 8424...........................................13
SPECIFICATIONS HI 8424 ..........................................................14
FUNCTIONAL DESCRIPTION HI 931000.......................................15
SPECIFICATIONS HI 931000 ...................................................... 16
FUNCTIONAL DESCRIPTION HI 9622...........................................17
SPECIFICATIONS HI 9622 ..........................................................18
OPERATIONAL GUIDE .................................................................19
pH CALIBRATION ....................................................................... 25
pH VALUES AT VARIOUS TEMPERATURES...................................35
TEMPERATURE CALIBRATION ...................................................... 36
mV OUTPUT..............................................................................36
TROUBLESHOOTING GUIDE ........................................................37
ELECTRODE CONDITIONING AND MAINTENANCE...........................39
TAKING REDOX MEASUREMENTS.................................................42
BATTERY REPLACEMENT .............................................................. 43
DISPLAY CODES GUIDE ...............................................................44
ACCESSORIES.............................................................................45
ELECTRODE APPLICATION REFERENCE GUIDE ................................ 52
WARRANTY ................................................................................53
OTHER PRODUCTS FROM HANNA ...............................................54
CE DECLARATION OF CONFORMITY .............................................. 55
ISO 9000 Certified Company since 1992
2
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during ship­ment. If noticeable damage is found, notify your Dealer.
Note: Save all packing material until you are sure that the
instrument functions correctly. Any defective items must be returned in the original packing together with the supplied accessories.
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
HI 8014, HI 8314, HI 8424, HI 8915, HI 931000 and HI 9622 are hand-held pH/mV meters. HI 9214 is a compact stick pH meter designed to be carried anywhere.
Common features are: interchangeable plastic-body electrodes, simple controls on the front panel, low battery detector, large easy-to-read LCD display, simple calibration procedure and lightweight ABS plastic housing.
HI 8014 is an affordable portable pH/mV meter ideally suited for the educational field. The pH or mV ranges are easily selected with a rotary knob. A °C range is also provided for manual temperature compensation. HI 8014 comes supplied with: HI 1332B combination, double-junction, refillable pH electrode and a 9 volt battery.
HI 8314 is a pH/mV/°C meter designed for simplicity of use in taking pH, mV (ORP) and temperature measurements. The pH, mV and °C ranges are easily selected using a membrane keyboard on the front panel. Temperature compensation of pH is automatic when the temperature probe is connected and calibra­tion adjustments are easily made with two trimmers on the front panel. HI 8314 comes supplied with: HI 1230B combination, double-junction, gel pH electrode, HI 7669AW temperature probe, a 9 volt battery and a calibration screwdriver.
HI 8424 is a portable microprocessor-based pH/mV/°C meter. It features a user-friendly membrane keyboard, automatic calibra­tion and error codes to guide the user in calibration and troubleshooting. The meter has three memorized buffer values:
3
pH 4.01, pH 7.01 and pH 10.01. It can also be used for ISE and ORP measurements with automatic range switching when readings exceed ±399.9 mV. HI 8424 comes supplied with: HI 1230B combination, double-junction, gel pH electrode, H I 7669AW temperature probe and a 9 volt battery.
HI 8915 is a portable pH/mV/°C meter that combines accurate pH measurements with a recorder output capability and auto­matic temperature compensation. Two recorder output terminals make it possible to attach a plotter or recorder directly to the meter for a hard copy of the measurements. Pressing the HOLD key will freeze the reading on the display. Calibration is per­formed using the two trimmers on the front panel. HI 8915 comes supplied with: HI 1230B combination, double-junction, gel pH electrode, HI 7669AW temperature probe, a 9 volt battery and a calibration screwdriver.
HI 9214 is a compact microprocessor-based pH/°C meter. The electrode has a built-in temperature sensor for quick and accurate temperature measurements and temperature compensation. The meter has three memorized buffer values (pH 4.01, pH 7.01, pH
10.01) and automatic buffer recognition to avoid errors during calibration. There are no trimmers making calibration an easy process, even for nontechnical personnel. HI 9214 comes supplied with: HI 1217S screw-type combination gel pH/°C electrode, a 9 volt battery and HI 710003 soft carrying case.
HI 931000 is a compact, microprocessor-based pH/°C meter with 4-in-1 pH electrode (pH/°C electrode with built-in temperature sensor and signal amplifier). Special shockproof rubberboots are also available to prolong the life of the meter and to prevent damage (see page 51). HI 931000 comes sup plied with : HI 1217D combination gel pH/°C electrode, with a built-in temperature sensor and signal amplifier, a 9 volt battery and HI 710004 soft carrying case.
HI 9622 is a portable microprocessor-based pH/mV/°C meter which meets the GLP (Good Laboratory Practice) requirements and memorizes the last calibration date. The meter has three memorized buffer values: pH 4.01, pH 7.01 and pH 10.01. The meter can also be used for ISE and ORP measurements with automatic range switching when readings exceed ±399.9 mV. HI 9622 comes supplied with: HI 1230B combination, double­junction, gel pH electrode, HI 7669/2W temperature probe and a 9 volt battery.
FUNCTIONAL DESCRIPTION HI 8014FUNCTIONAL DESCRIPTION HI 8014
FUNCTIONAL DESCRIPTION HI 8014
FUNCTIONAL DESCRIPTION HI 8014FUNCTIONAL DESCRIPTION HI 8014
1
2
pH
pH meter
°C
OFF
HI 8014
pH
mV
3
°C mV/pH
4
ins rum n
AP
s
1) BNC socket for combination pH electrodes.
2) LCD display.
3) Rotary Knob with the following selectable positions: OFF To switch the meter off (in any other position the
instrument is on).
°C To display the manual temperature setting (through
°C trimmer).
pH To display the pH value. mV To display the mV (ORP) readings when using an
ORP electrode or the mV equivalent to the pH values when using a pH electrode.
4) Trimmers:
°C To set temperature manually. mV/pH For SLOPE calibration of pH. AP For OFFSET calibration of pH.
4
5
SPECIFICATIONS HI 8014SPECIFICATIONS HI 8014
SPECIFICATIONS HI 8014
SPECIFICATIONS HI 8014SPECIFICATIONS HI 8014
FUNCTIONAL DESCRIPTION HI 8314FUNCTIONAL DESCRIPTION HI 8314
FUNCTIONAL DESCRIPTION HI 8314
FUNCTIONAL DESCRIPTION HI 8314FUNCTIONAL DESCRIPTION HI 8314
HI 8014
Range pH 0.00 to 14.00
mV 0 to ±1999
Resolution pH 0.01
mV 1
Accuracy pH ±0.01 (@20°C/68°F) mV ±1
Typical EMC pH ±0.05 Deviation mV ±8
pH Calibration Manual 2 point through
offset and slope trimmers
Offset Calibration ±1 pH Slope Calibration from 85 to 105% Temperature Manual from 0 to 100°C
Compensation (32 to 212°F) Electrode HI 1332B combination, double-junction,
refillable pH electrode BNC
and 1 m (3.3') cable (included)
Input Impedance 1012 ohm Battery Type 1 x 9 volt
Life 100 hours of continuous use Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 185 x 82 x 45 mm
(7.3 x 3.2 x 1.8")
Weight 520 g (1.1 lb.)
1
2
3 4
pH
HI 8314 membrane pHmeter
mV
STD 1nd
Calibration at pH
6.86 or 7.01
CALIBRATION
ON
OFF
pH
°C
SLOPE 2nd Calibration at pH
4.01 or 10.01
5
6 7 8
9
1) BNC socket for combination pH or ORP electrodes.
2) LCD display.
3) mV to display the mV (ORP) readings when using an ORP electrode or the mV equivalent to pH values when using a pH electrode.
4) STD trimmer for OFFSET calibration of pH.
5) Phono plug socket for temperature probe HI 7669AW.
6) ON/OFF to switch the instrument on or off.
7) pH to display the pH value.
8) °C to display the temperature measurement (when the temperature probe is disconnected, the LCD will show 25°C).
9) SLOPE trimmer for SLOPE calibration of pH.
6
7
SPECIFICATIONS HI 8314SPECIFICATIONS HI 8314
SPECIFICATIONS HI 8314
SPECIFICATIONS HI 8314SPECIFICATIONS HI 8314
FUNCTIONAL DESCRIPTION HI 8915FUNCTIONAL DESCRIPTION HI 8915
FUNCTIONAL DESCRIPTION HI 8915
FUNCTIONAL DESCRIPTION HI 8915FUNCTIONAL DESCRIPTION HI 8915
HI 8314
Range pH 0.00 to 14.00
mV 0 to ±1999
°C 0.0 to 100.0
Resolution pH 0.01
mV 1
°C 0.1
Accuracy pH ±0.01 (@20°C/68°F) mV ±1
°C ±0.4
Typical EMC pH ±0.05 Deviation mV ±5
°C ±1
pH Calibration Manual 2 point through
offset and slope trimmers
Offset Calibration ±1 pH Slope Calibration from 85 to 105% Temperature Automatic from 0 to 70°C (32 to 158°F)
Compensation or fixed at 25°C (77°F)
with temperature probe detached
Electrode HI 1230B combination, double-junction,
gel-filled pH electrode BNC
and 1 m (3.3') cable (included)
Temperature HI 7669AW (included)Probe
Input Impedance 1012 ohm Battery Type 1 x 9 volt
Life 100 hours of continuous use Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 185 x 82 x 45 mm
(7.3 x 3.2 x 1.8")
Weight 570 g (1.3 lb.)
1
2
3
4 5
6
pH
HI 8915 ATC pHmeter
HOLD
mV
OFFSET
+-
6.86
7.00
mV OUTPUT
CALIBRATION
ON
OFF
pH
°C
SLOPE
4.01
10.01
7
8 9
10
11
12
1) BNC socket for combination pH or ORP electrodes.
2) LCD display.
3) HOLD to freeze the reading on the display.
4) mV to display the mV (ORP) readings when using an ORP electrode or the mV equivalent to the pH values when using a pH electrode.
5) OFFSET trimmer for OFFSET calibration of pH
6) + recorder output (mV output, positive connection).
7) Phono plug socket for temperature probe HI 7669AW.
8) ON/OFF to switch the instrument on or off.
9) pH to display the pH value.
10) °C to display the temperature measurement (when the temperature probe is disconnected, the LCD will show 25°C).
11) SLOPE trimmer for SLOPE calibration of pH.
12) - recorder output (mV output, negative connection).
8
9
SPECIFICATIONS HI 8915SPECIFICATIONS HI 8915
SPECIFICATIONS HI 8915
SPECIFICATIONS HI 8915SPECIFICATIONS HI 8915
FUNCTIONAL DESCRIPTION HI 9214FUNCTIONAL DESCRIPTION HI 9214
FUNCTIONAL DESCRIPTION HI 9214
FUNCTIONAL DESCRIPTION HI 9214FUNCTIONAL DESCRIPTION HI 9214
HI 8915
Range pH 0.00 to 14.00
mV 0 to ±1999
°C 0.0 to 100.0
Resolution pH 0.01
mV 1
°C 0.1
Accuracy pH ±0.01 (@20°C/68°F) mV ±1
°C ±0.5
Typical EMC pH ±0.02 Deviation mV ±1
°C ±0.8
pH Calibration Manual 2 point through
offset and slope trimmers
Offset Calibration ±1 pH Slope Calibration from 85 to 105% Temperature Automatic from 0 to 70°C (32 to 158°F)
Compensation or fixed at 25°C (77°F)
with temperature probe detached
Electrode HI 1230B combination, double-junction,
gel-filled pH electrode BNC
and 1 m (3.3') cable (included)
Temperature HI 7669AW (included)Probe
CFM
s n
e
rum
CAL
ins
ON
OFF
H
p
HI 9214 stick pHmeter
1
2
3
4
5
6
Input Impedance 1012 ohm Recorder Output 100 mV/pH
1mV/mV 10mV/°C
Battery Type 1 x 9 volt Life 100 hours of continuous use
Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 185 x 82 x 45 mm
(7.3 x 3.2 x 1.8")
Weight 570 g (1.3 lb.)
10
1) °C button, located on the top of the meter, to display temperature measurements.
2) CFM to confirm calibration values.
3) CAL to enter calibration mode or to select buffer.
4) ON/OFF to switch the instrument on or off.
5) LCD display.
6) Screw-type socket for combination pH electrode with built-in temperature sensor.
11
SPECIFICATIONS HI 9214SPECIFICATIONS HI 9214
SPECIFICATIONS HI 9214
SPECIFICATIONS HI 9214SPECIFICATIONS HI 9214
HI 9214
Range pH 0.00 to 14.00
°C 0.0 to 70.0
Resolution pH 0.01
°C 0.1
Accuracy pH ±0.02 (@20°C/68°F) °C ±0.5
Typical EMC pH ±0.08 Deviation °C ±1
pH Calibration Automatic 2 point with
3 memorized standard buffers
(pH 7.01, 4.01 or 10.01)
Offset Calibration ±1 pH Slope Calibration from 85 to 105% Temperature Automatic from 0 to 70°C
Compensation (32 to 158°F) Electrode HI 1217S gel combination
pH/°C (included) Input Impedance 1012 ohm Battery Type 1 x 9 volt
Life 100 hours of continuous use
Auto-off after 8 minutes of non-use
Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 185 x 42 x 26 mm
(7.3 x 1.6 x 1.0")
Weight 350 g (12.3 oz.)
FUNCTIONAL DESCRIPTION HI 8424FUNCTIONAL DESCRIPTION HI 8424
FUNCTIONAL DESCRIPTION HI 8424
FUNCTIONAL DESCRIPTION HI 8424FUNCTIONAL DESCRIPTION HI 8424
1) BNC socket for combination pH or ORP electrodes.
2) LCD display.
3) RANGE to select the pH, °C or mV range.
4) UP arrow to set temperature manually when the temperature probe is disconnected.
5) CAL to enter calibration mode.
6) Phono plug socket for temperature probe HI 7669AW.
7) ON/OFF to switch the instrument on or off.
8) DOWN arrow to set temperature manually when the temperature probe is disconnected.
9) CFM to confirm calibration data.
12
13
SPECIFICATIONS HI 8424SPECIFICATIONS HI 8424
SPECIFICATIONS HI 8424
SPECIFICATIONS HI 8424SPECIFICATIONS HI 8424
FUNCTIONAL DESCRIPTION HI 931000FUNCTIONAL DESCRIPTION HI 931000
FUNCTIONAL DESCRIPTION HI 931000
FUNCTIONAL DESCRIPTION HI 931000FUNCTIONAL DESCRIPTION HI 931000
HI 8424
Range pH 0.00 to 14.00
ISE 0.0 to ±399.9 mV
ORP ±400 to ±1999 mV
°C 0.0 to 100.0
Resolution pH 0.01
ISE 0.1mV
ORP 1mV
°C 0.1
Accuracy pH ±0.01 (@20°C/68°F) ISE ±0.2mV
ORP ±1mV
°C ±0.4
Typical EMC pH ±0.02 Deviation ISE ±0.2
ORP ±1
°C ±0.4
pH Calibration Automatic 2 point with
3 memorized standard buffers
(pH 7.01, 4.01 or 10.01)
Offset Calibration ±1.0 pH Slope Calibration from 70 to 108% Temperature Automatic from 0 to 100°C (32 to 212°F)
Compensation or manual without temperature probe Electrode HI 1230B combination, double-junction,
gel pH electrode BNC
and 1 m (3.3') cable (included)
Temperature HI 7669AW (included)Probe Input Impedance 1012 ohm Battery Type 1 x 9 volt
Life 100 hours of continuous use Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 185 x 82 x 45 mm
(7.3 x 3.2 x 1.8")
Weight 520 g (1.1 lb.)
1
s
ins
rum n
2
ON
OFF
°C
3
4 5
CAL
CFM
HI 931000
6
1) DIN socket for combination pH/°C electrode.
2) LCD display.
3) ON/OFF to switch the instrument on or off.
4) °C to display the measured temperature (press and hold).
5) CAL to enter calibration mode.
6) CFM to confirm calibration data.
14
15
SPECIFICATIONS HI 931000SPECIFICATIONS HI 931000
SPECIFICATIONS HI 931000
SPECIFICATIONS HI 931000SPECIFICATIONS HI 931000
HI 931000
Range pH 0.00 to 14.00
°C 0.0 to 70.0
Resolution pH 0.01
°C 0.1
Accuracy pH ±0.01 (@20°C/68°F) °C ±0.5
Typical EMC pH ±0.30 Deviation °C ±1
pH Calibration Automatic 2 point with
3 memorized standard buffers
(pH 7.01, 4.01, 10.01)
Temperature Automatic from 0 to 70°C Compensation (32 to 158°F)
Electrode HI 1217D combination 4-in-1 gel
pH electrode with built-in temperature
sensor and amplifier (included)
Battery Type 1 x 9 volt Life 300 hours of continuous use
Auto-off after 8 minutes of non-use
Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 143 x 80 x 38 mm
(5.6 x 3.2 x 1.5")
Weight 360 g (12.7 oz.)
FUNCTIONAL DESCRIPTION HFUNCTIONAL DESCRIPTION H
FUNCTIONAL DESCRIPTION H
FUNCTIONAL DESCRIPTION HFUNCTIONAL DESCRIPTION H
1) BNC socket for combination pH or ORP electrode.
2) LCD display.
3) RANGE to select the pH, °C or mV range.
4) UP arrow to set the month and day for calibration data recall and the temperature for manual compensation (when the temperature probe is disconnected).
5) CAL to enter calibration mode.
6) Socket for temperature probe HI 7669/2W.
7) ON/OFF to switch the instrument on or off.
8) DOWN arrow to set the month and day for calibration data recall and the temperature for manual compensation (when the temperature probe is disconnected).
9) CFM to confirm calibration data.
I I
I
I I
96229622
9622
96229622
16
17
Loading...
+ 20 hidden pages