Hanna Instruments HI190M-0 User manual

Instruction Manual
HI 190 - HI 200
Magnetic Stirrers
These Stirrers are in
Compliance with the CE Directives
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Dear Customer, Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for the correct operation of the instrument. Please read it carefully before using the device. If you need additional technical informa­tion, do not hesitate to e-mail us at techserv@hannacan.com.
These instruments are in compliance with directives EN 50081-1 and EN 50082-1.
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
Remove the instrument from the packing material and ex­amine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center.
Note: Conserve all packing material until the instrument has
been observed to function correctly. Any defective item must be returned to the Dealer in its original packing.
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
HI 190M, HI 190MB and HI 200M are compact and light­weight magnetic stirrers. They incorporate electronic controls that allow the user to regulate the speed with greater preci­sion. In addition to speed control, a limiter will assure that the maximum speed (1000 rpm) will never be exceeded. HI 190M and HI 190MB have a plastic cover that will resist the harmful effects of chemicals that are accidentally spilled.
HI 200M is supplied with an AISI 316 stainless steel cover. This model is ideal for applications that create exothermic reactions.
Each stirrer is supplied complete with a 25 mm long (7 mm as diameter), Teflon® coated, magnetic stir bar.
Teflon® is registered Trademark of "du Pont de Nemours & Co."
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
HI 190M HI190MB HI 200M
Max Stirring 1 liter Capacity (0.26 gallons)
Speed Range Min. 100 rpm Max. 1000 rpm
Power Supply HI 190M/U 110/115V, 50/60 Hz HI 190M/D 220/240V , 50/60 Hz HI 190MB 12VDC HI 200M/U 110/115V, 50/60 Hz HI 200M/D 220/240V , 50/60 Hz
Installation II Category
Cover Material HI 190M ABS plastic HI 190MB ABS plastic HI 200M AISI 316 Stainless Steel
Environment 0 to 50°C (32 to 122°F)
Max. 95% RH non-condensing
Dimensions 120 x 120 x 45 mm
(4.8 x 4.8 x 1.8")
Weight HI 190M 640g (1.4 lb) HI 190MB 610g (1.3lb) HI 200M 710 g (1.6 lb)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTION
FUNCTIONAL DESCRIPTIONFUNCTIONAL DESCRIPTION
THE FRONT PANEL
1) Power indication (LED lights up when there is power supply)
2) Speed knob (for rpm setting with ON/OFF) continuously variable up to the maximum.
THE REAR PANEL OF HI 190M AND HI 200M
1) Fuse holder for 200-250V fuse
2) AC power cord.
THE REAR PANEL OF HI 190MB
1) Fuse holder for 200-250V fuse
2) DC power socket (for HI710005 or HI710006)
Unplug the stirrers from the power supply before re­placing the fuse.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDE
OPERATIONAL GUIDEOPERATIONAL GUIDE
• Make sure that the SPEED knob is in the OFF position.
MAGNETIC STIRRER HI 190M
POWER
ON
OFF MAX
SPEED
• Place a beaker or glass container on the top of the stirrer and place the stirring bar at the center of the beaker base.
MAGNETIC STIRRER HI 190M
POWER
ON
OFF MAX
SPEED
• Pour the liquids to be mixed into the beaker. Do not fill to the brim and leave sufficient space to prevent spillage during stirring.
MAGNETIC STIRRER HI 190M
POWER
ON
OFF MAX
SPEED
• Connect the power cord to the mains.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
• Adjust the SPEED knob slowly until the required stirring speed is achieved.
MAGNETIC STIRRER HI 190M
POWER
ON
OFF MAX
SPEED
• Allow sufficient time for the mixing operation to attain uniform rotational flow.
• After stirring is completed, turn the SPEED knob to OFF position.
MAGNETIC STIRRER HI 190M
POWER
ON
OFF MAX
SPEED
• If no further stirring is required, disconnect the power supply.
ACCESSORIESACCESSORIES
ACCESSORIES
ACCESSORIESACCESSORIES
HI 710005 115VAC to 12VDC power adapter (for HI190MB
only)
HI 731319 Micro stir bar (10 each)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
CE DECLARATIONCE DECLARATION
CE DECLARATION
CE DECLARATIONCE DECLARATION
OF CONFORMITYOF CONFORMITY
OF CONFORMITY
OF CONFORMITYOF CONFORMITY
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environ­ment in which they are used.
Operation of these instruments in residential area could cause unacceptable interfer­ences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance.
Unplug the stirrers from the power supply before replacing the fuse.
To avoid damages or burns, do not place these stirrers in microwave ovens.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
WARRANTYWARRANTY
WARRANTY
WARRANTYWARRANTY
All Hanna Instruments products are warranted for two years against defects in workmanship and materials when
used for their intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service de­partment and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection.
To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc.
Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
ISTR190R3 09/04PRINTED IN CANADA
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...