HAMPTON BAY Northport 178-047 Owner's Manual

Northport 52
in Ceiling Fan
Owner’s Manual
Northport Ventilador de Techo de 1,32
m
Manual del Propietario
Northport by Hampton Bay
®
52” Northport
Ceiling Fan by Hampton Bay
Date Purchased
Store Purchased
UL Model No.
Serial No.
Vendor No.
UPC
Thank you for purchasing our ceiling fan. This product has been manufactured with the highest standards of safety and quality.
Table of Contents
Safety Rules . . . . . . . . . . . . . . . . . . . . 1
Unpacking Your Fan . . . . . . . . . . . . . . 2
Installing Your Fan . . . . . . . . . . . . . . . 3
Installing the Light Kit . . . . . . . . . . . . 9
Operating Your Fan . . . . . . . . . . . . . 10
Care or Your Fan . . . . . . . . . . . . . . 11
Troubleshooting . . . . . . . . . . . . . . . 11
Specifications . . . . . . . . . . . . . . . . . . 12
Warranty Information . . . . . . . . . . . . 13
718212149263
219054
178-047
Safety Rules - Read and Save These Instructions
1
To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
WARNING: To reduce the risk of electrical shock or fire, do not use this fan with any solid-state fan speed control device. It will permanently damage the electronic circuitry.
CAUTION: To reduce the risk of personal injury, use only the screws provided with the outlet box.
The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds. Use only UL Listed outlet boxes marked “FOR FAN SUPPORT”.
The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
Avoid placing objects in path of the blades.
To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
After making electrical connections, spliced conductors should be turned upward and pushed carefully up into outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
All set screws must be checked and retightened where necessary before installation.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
WARNING
TO REDUCE THE RISK OF PERSONALL INJURY, DO NOT BEND THE BLADE HOLDERS (ALSO REFERRED TO AS FLANGES), WHEN INSTALLING THE HOLDERS, BALANCING THE BLADES OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS IN– BETWEEN ROTATING FAN BLADES.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX.
ATTENTION
FAN INCLUDES A 190W LIMITER TO COMPLY WITH THE DEPARTMENT OF ENERGY 2009 REGULATION. LAMPING THIS PRODUCT OVER 190W WILL CAUSE THIS FAN TO NOT LIGHT. PLEASE USE BULBS WITH A TOTAL WATTAGE UNDER THE 190W REGULATION.
2
Unpacking Your Fan
Unpack your fan and check the contents. You should have the following items:
AB
C
Set of blades (4)
Canopy assembly
Standard Ball/downrod assembly
Minimum-length downrod (for close to the ceiling installation only)
Coupling cover
1.
2.
3a.
3b.
4.
Fan motor assembly
Light kit mounting plate
Light kit assembly
Glass shade
75 Watt halogen bulb
Pull chains and fobs (2)
5.
6.
7.
8.
9.
10.
Electrical Hardware (3 Plastic Wire Nuts)
Blade Attachment Hardware 3/16"×12.3mm Screws (13PCs.) Fiber Washers (13PCs.)
Balancing Kit
A.
B.
C.
WARNING
DO NOT INSTALL OR USE FAN IF ANY
PART IS DAMAGED OR MISSING.
CALL TOLL FREE 1-800-527-0998.
1
2
3a
3b
4
5
6
7
8
9
10
Loading...
+ 11 hidden pages