Window Requirements
Your new room air conditioner is factory prepared
for easy installation in a horizontal sliding or casement type window with a minimum width of 15
1/2 inches. Unit will fit a 42 inch high window
opening as received from factory.
Caution: Do not block air circulation to outside louvers
of cabinet.
Tools Needed
p
Blade-type screwdriver
p
Ruler
p
Drill
p
Awl
p
1/8 inch drill bit
p
Knife
p
Level
p
Pencil
Important
Grounding Requirements
1. Air conditioner has a three-prong grounding
plug on power supply cord, which must be
plugged into properly grounded three-prong
wall receptacle for your protection against
possible shock hazard. For models up to and
including 7.5 amperes use grounding type
wall receptacle to match cord plug (Fig. 1).
2. For models above 7.5 amperes use single
outlet grounding type wall receptacle to
match cord plug (Fig. 2).
Caution: We recommend that a qualified electrician
install unit in accordance with the National Electrical
Code and local codes and ordinances.
Caution: Use copper conductors only.
INSTALLATION
Three-prong
grounding plug
Single outlet
grounding
wall receptacle
Grounded
three-prong
wall receptacle
1 2
1. ELECTRICAL REQUIREMENTS
WARNING
Electrical Shock Hazard
1. Plug unit only into grounded electrical outlet.
2. Do not use an extension cord or plug adaptor with
this unit.
3. Do not operate unit with front removed.
Failure to follow the above precautions could result in electrical
shock, fire or personal injury.
If the air conditioner has a serial plate rating of 115 volts
and up to and including 7.5 amps the unit may be on a fuse
or circuit breaker with other devices.
However, the maximum
amps of all devices on that fuse or circuit breaker can not
exceed the amps of the fuse or circuit breaker.
If the air conditioner has a serial plate rating of 115 volts
and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on that fuse or circuit breaker.
The location of the serial plate that applies to this model
can be found on the back page of this manual.
Product Damage:
Do not cut, alter or remove any of the expanded polystyrene
(white foam) inside this air conditioner.
For Your Safety:
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance. The
fumes can create a fire hazard or explosion.
WARNING
Notice
Do not operate this air conditioner without proper time
delay circuit protection. Refer to serial plate for proper
power supply requirements.
RECOMMENDED CIRCUIT WIRE SIZES
(As installed per building code)
PROTECTOR SIZE WIRE GAUGE
15 AMP #14 MINIMUM
20 AMP #12 MINIMUM
30 AMP #10 MINIMUM
115V 230V 230V 230V
15A 15A 20A 30A