HAMAMATSU F6492 Datasheet

Very Long (Effective Area: 127 4mm)
This new long-scale MCP allows for continuous detection of wide range position information without dead space cor­rection. This new configuration promises reliable measure­ment, and is well suited for double-focusing mass spec­trometers. Assembled configurations are also available upon request.
FEATURES
Long Scale (Effective Area: 127mm 4mm) Simultaneous Multielement Measurement Possible Sensitive to Ions, Electrons, UV Radiation, Soft X-rays, -rays and High Energy Particles High Gain (1 10
4
)
LONG SCALE MICROCHANNEL PLATE
F6492
TMCPF0064
APPLICATIONS
SIMS (Secondary Ions Mass Spectrometers) UV Spectrometers X-ray Spectrometers Electron Spectrometers
GENERAL
Parameter
Outer Dimension Electrode Dimension Effective Area Dimension Thickness Channel Diameter Channel Pitch Bias Angle Open Area Ratio Electrode Material
CHARACTERISTICS (at 1000V, 1.3 10
Parameter
Current Gain Min. Plate Resistance Maximum Dark Current Maximum Linear Output Current
MAXIMUM RATINGS (Absolute Values)
Parameter
Supply Voltage Ambient Temperature
Strip current is current flowing through the channel walls, which supplies
NOTE:
:
the current released from the channel walls. It is given by: Supply voltage / Plate resistance. At a vacuum of 1.3 10
:
-4
Description/Value
140 9 138 8 127 4
Inconel
Discription/Value
1 10
10 to 100
5 10
up to 7% of the strip current
Discription/Value
-50 to +50
Pa (1 10-6 Torr) or better.
Unit
0.48 12 15
8
60
Pa (1 10-6 Torr), 25 )
Unit
4
-13
A/cm
Unit
1000
mm mm mm mm m m
%
M
V
Figure 1: Typical Current Gain
TMCPB0036EA
5
10
4
10
CURRENT GAIN
3
10
2
2
10
500 800 1000
600 700 900 1100
SUPPLY VOLTAGE (V)
Subject to local technical requirements and regulat ions, availability of products included in this promotional material may va r y. Please consult with our sales office. lnformation furnished by HAMA M ATSU is believed to be reliabIe. However, no responsibility is assumed for possibIe inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein.
1996 Hamamatsu Photonics K.K.
©
LONG SCALE MICROCHANNEL PLATE F6492
Figure 2: Dimensional Outline (Unit: mm)
EFFECTIVE AREA ELECTRODE INDICATOR
127 138
0.48
8
9
8
4
Figure 3: Application Example to SIMS
SIGNAL DISPLAY SYSTEM
CRT
RECORDER
120457 9
COUNTER
SAMPLE
PRIMARY ION IRRADIATION SYSTEM
SECONDARY ION MASS ANALYZER SYSTEM
SECTOR ELECTRIC FIELD
ION GUN
LONG SCALE MCP ASSEMBLY + PHOSPHOR SCREEN + LINEAR IMAGE SENSOR
140
TMCPA0023EB
1)
PRECAUTIONS FOR USE
Avoid touching the MCP or MCP assembly with bare hands.
Handle the MCP only in a clean room since dust and humidity may adversely affect MCP
SLIT
1
S
SECTOR MAGNETIC FIELD
TMCPC0038EA
characteristics. The MCP should be operated in vacuum below
1.33 10-4 Pa (1 10-6 torr). The MCP should be kept in vacuum or dry nitrogen
gas atmosphere during long periods of storage. When outgassing from the MCP occurs, baking the
MCP at 350 C maximum in a vacuum system is recommended. In addition electron bombarding may be effective.
REFERENCE
1) Japan Academic Promotion Society, 141th Committee on Micro Beam Analysis: “Micro beam analysis” Asakura Shoten, 293 (1985)
HAMAMATSU PHOTONICS K.K., Electoron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.:
Hamamatsu Corporation: 360 Foothill Road, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218
Germany:
Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658
France:
Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10
United Kingdom: North Europe: Italy:
Hamamatsu Photonics UK Limted: Lough Point, 2 Gladbeck Way, Windmill Hill, Enfield, Middlesex EN2 7JA, United Kingdom, Telephone: (44)181-367-3560, Fax: (44)181-367-6384
Hamamatsu Photonics Norden AB: Färögatan 7, S-164-40 Kista Sweden, Telephone: (46)8-703-29-50, Fax: (46)8-750-58-95
Hamamatsu Photonics Italia: S.R.L.: Via Della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)2-935 81 733, Fax: (39)2-935 81 741
TMCP1009E05 JAN. 1997 SI (9609) Printed in Japan
Loading...