Hakko 900M, 900L, 907, 908, 913 User Manual

...
No.A1321
No.A1321(900M • 900L • 907 • 908 • 913 • 914 • 951 • 952 )
Replacing the Heating Element
900M/L 907/908/913/914 951/952
Nut
Tip Enclosure Tip
Glass Tube
Grounding Spring Heating Element
1
Checking the heating element
Heating Element Leads (Red)
Sleeve
Terminal Board Handle
1. Remove the nut, tip enclosure, tip and nipple.
CAUTION Be sure to remove the nut before removing the
nipple. Removing the nipple first could cause the heater leads to twist and cause a short-circuit.
3. Remove the grounding spring from the sleeve.
4. Measure the resistance values at the sensor and heating element of the terminal board in normal condition.
Resistance value of heating element (red) 2.5–3.5 Resistance value of sensor (blue) 43–58
If the value you get is outside this range, replace the heating element. If the resistance value is normal, the cord assey may be broken.
Resistance Value of Heating Element
2
Replacing the heating element
Resistance Value of Sensor
Sensor Leads (Blue)
1. Desolder the heating element leads and sensor leads.
2. Remove the old heating element and replace it with a new one.
3. Bend the leads at right angle.
4. Pass the leads through the terminal, push the lead down inside the terminal board, then solder it. Be sure that the insulation covering the lead is long enough to leave NO
exposed wire. Cut the wire to leave no more than 1 to 2mm from the solder joint. Move the tube back to its original position for ESD safe type.
Solder in the joints must be visible from both sides of
the terminal board.
There is no polarity between leads of the same colors.
64mm (2.52in)
Bend at right angle.
Straighten the tube.
3
Inspection after replacement
and reassemble
After replacing the heating element,
1. Measure the resistance value between pins 4 & 1 and 4 & 2, and pins 5 & 1 and 5 & 2. If it is not infinite, the heating element and sensor are touching.
2. Measure the resistance value a, b, and c to confirm that the leads are not twisted and that the grounding spring is properly connected.
a
Between pins 4 & 5 (Heating Element) 2.5 - 3.5 (Normal)
b
Between pins 1 & 2 (Sensor) 43 - 58 (Normal)
c
Between pin 3 & Tip
4
Recalibrate the temperature
To ensure accurate soldering temperatures, always calibrate the temperature after replacing the heating element. Connect your iron/gun to the station for calibration.
For HAKKO 926 • 928 • 936 • 700 • 701• 702 • 702B
1. Set the temperature control knob to 400°C (750°F).
2. Turn the power switch on and wait until the L.E.D. heater lamp comes on and off.
3. Using a straight-edge (–) or small cross point screwdriver, adjust the temperature calibrator (marked CAL) so that the tip temperature is 400°C (750°F).
* Turn the temperature calibrator clockwise to increase the temperature and counterclockwise to reduce the temperature. * Using the supplied hex wrench, remove the screw (M4×5mm) labeled CAL on the bottom of the station, and then turn the power on (HAKKO 927). * Remove the CAL pot plug before calibrating HAKKO 936/937. * We recommend the HAKKO 191/192 thermometer for measuring the tip temperature.
Under 2
Nipple
4
5
Red
Heating element lead
3
Nut Tip Enclosure Tip
Sleeve
Heating Element Glass Tube Terminal Board
*HAKKO 913 and 914 are different from HAKKO 907 and 908 in shape of the handle.
1
Checking the heating element
Nipple Grounding Spring
Handle
1. Remove the nut, tip enclosure, tip and nipple.
CAUTION Be sure to remove the nut before removing the
nipple. Removing the nipple first could cause the heater leads to twist and cause a short-circuit.
2. Push the cord assey in the direction of the tip and remove the terminal board from the handle.
3. Remove the grounding spring from the sleeve.
4. Measure the resistance values at the sensor and heating element of the terminal board in normal condition.
Resistance value of heating element (red) Resistance value of sensor (blue) 43–58
If the value you get is outside this range, replace the heating element. If the resistance value is normal, the cord assey may be broken.
Resistance Value of Heating Element
2
Replacing the heating element
2.5–3.5
Resistance Value of Sensor
Heating Element Leads (Red)
1. Desolder the heating element leads and sensor leads.
2. Remove the old heating element and replace it with a new one.
3. Bend the leads at right angle.
4. Pass the leads through the terminal, push the lead down inside the terminal board, then solder it. Be sure that the insulation covering the lead is long enough to leave NO exposed wire. Cut the wire to leave no more than 1 to 2mm from the solder joint.
Solder in the joints must be visible from both sides of
the terminal board.
There is no polarity between leads of the same colors.
64mm (2.52in)
Straighten the tube.
3
Inspection after replacement
Bend at right angle.
and reassemble
After replacing the heating element,
1. Measure the resistance value between pins 4 & 1 and 4 & 2, and pins 5 & 1 and 5 & 2. If it is not infinite, the heating element and sensor are touching.
2. Measure the resistance value a, b, and c to confirm that the leads are not twisted and that the grounding spring is properly connected.
a
Between pins 4 & 5 (Heating Element) 2.5 - 3.5 (Normal)
b
2
1
Between pins 1 & 2 (Sensor) 43 - 58 (Normal)
c
Between pin 3 & Tip
Under 2
For HAKKO 927 • 937
1. Turn the power switch on and insert the card. Set the temperature to 400°C (750°F).
2. Wait until the digital display indicates a tip temperature of 400°C (750°F).
3. Using a straight-edge (–) or small cross point screw­driver, adjust the temperature calibrator (marked CAL) so that the tip temperature is 400°C (750°F).
Support Fitting
1
Checking the heating element
1. Remove the adjusting screw and keep the support fitting apart from the housing.
CAUTION Be sure to remove the nut before removing the
2. Remove the four screws securing the housing and open the housing.
3. Remove the grounding spring from the sleeve.
4. Measure the resistance values at the sensor and heating element of the terminal board in normal condition.
Resistance value of heating element (red) Resistance value of sensor (blue) 43–58
If the value you get is outside this range, replace the heating element. If the resistance value is normal, the cord assey may be broken.
2
Replacing the heating element
1. Desolder the heating element leads and sensor leads.
2. Remove the old heating element and replace it with a new one.
3. Bend the leads at right angle.
4. Pass the leads through the terminal, push the lead down inside the terminal board, then solder it. Be sure that the insulation covering the lead is long enough to leave NO exposed wire. Cut the wire to leave no more than 1 to 2mm
Red
from the solder joint.
Solder in the joints must
be visible from both sides of the terminal board.
Heating element lead
There is no polarity between leads of the same colors.
Inspection after replacement
3
and reassemble
After replacing the heating element,
1. Measure the resistance value between pins 4 & 1 and 4 & 2, and pins 5 & 1 and 5 & 2. If it is not infinite, the heating element and sensor are touching.
2. Measure the resistance value a, b, and c to confirm that the leads are not twisted and that the grounding spring is properly connected.
a
Between pins 4 & 5 (Heating Element) 2.5 - 3.5 (Normal)
b
3
4
5
2
1
Between pins 1 & 2 (Sensor) 43 - 58 (Normal)
c
Between pin 3 & Tip
CAUTION
When reassembling, match the convex part of the hexagon nut to concave part of the housing.
NOTE When repairs are needed, please send both the soldering iron and
the station to your sales agent. * Specifications subject to change without notice.
®
HEAD OFFICE
4-5, SHIOKUSA 2-CHOME, NANIWA-KU, OSAKA, 556-0024 JAPAN TEL:+81-6-6561-3225 FAX:+81-6-6561-8466 http://www.hakko.com
OVERSEAS AFFILIATES
U.S.A.: AMERICAN HAKKO PRODUCTS, INC.
TEL: (661) 294-0090 FAX: (661) 294-0096 Toll Free (800)88-HAKKO
4 2 5 5 6
http://www.hakkousa.com
S'PORE: HAKKO PRODUCTS PTE., LTD.
TEL: 748-2277 FAX: 744-0033
MALAYSIA: HAKKO PRODUCTS SDN BHD MALAYSIA HEAD OFFICE: PETALING JAYA
TEL: (03)519-5223 FAX: (03)519-5221
PENANG BRANCH: TEL: (04)507-0888 FAX: (04)507-0999 JOHORE BAHRU BRANCH: TEL: (07)236-7766 FAX: (07)237-4655 PHILIPPINES: HAKKO PHILS TRADING CO., INC.
TEL: (02)817-0712, 815-4993 FAX: (02)810-7649
Grounding
Spring
Adjusting Screw
nipple. Removing the nipple first could cause the heater leads to twist and cause a short-circuit.
Resistance Value of Sensor
2.5–3.5
Bend at right angle.
Heating element lead
Under 2
Hexagon nut M4
INDONESIA: P.T. HAKKO PRODUCTSTAMA INDONESIA. TEL: (778)457-459 FAX: (778)452-772
P.T. HAKKO PRODUCTSTAMA INDONESIA
TEL: (21)532-4083 FAX: (21)532-4082
HONG KONG: HAKKO DEVELOPMENT CO., LTD.
TEL: 2811-5588 FAX: 2590-0217 http://www.hakko.com.hk/
CHINA: HAKKO DEVELOPMENT CO., LTD.
TEL: (020)8135-0112, 8135-0113 FAX: (020)8135-0181
TAIWAN: HAKKO DEVELOPMENT CO., LTD.
TEL: (02)2975-2600 FAX: (02)2973-9565
Tip
Tip Enclosure
Resistance Value of Heating Element
64mm (2.52in)
4
5
Nut
3
2
1
Sep. 2001