Haier V1124C2H, V1118C2H, V1136C2H, V1130C2H, V1142C2H Installation & Operation Manual

...
0 (0)
No.0010576764A
Capacity 1.5 to 5 Tons Models: V1118C2H V1124C2H V1130C2H V1136C2H
Installation & Operation Manual
Central Air Conditioner
V1142C2H V1148C2H V1160C2H V1160C3H
! WARNING
These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical shock, property damage, personal injury or death. This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer's responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations. The manufacturer assumes no responsibility for equipment installed
in violation of any codes or regulations.
The United States Environmental Protection Agency (EP A) has issued various r egulations regarding the introduction and disposal of refrigerants in this unit. Failure to follow these regulations may harm
the environment and can lead to the imposition of substantial fines. Because these regulations may vary due to the passage of new laws we suggest that any work on this unit be done by a certified technician. Should you have any questions please contact the local EPA office. The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of any components, accessories or devices (other than those authorized by the manufacturer) into, onto, or in conjunction with the air conditioner. You should be aware that the use of unauthorized
components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or
injury resulting from the use of such unauthorized components, accessories or devices. Attach the service panel to the outdoor unit securely. If the service panel is not attached securely, it could result in a fire or an electric shock due to dust, water, etc. These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical shock, property damage, personal injury or death. This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer's responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations. The manufacturer assumes no responsibility for equipment installed
in violation of any codes or regulations.
The United States Environmental Protection Agency (EP A) has issued various r egulations regarding the introduction and disposal of refrigerants in this unit. Failure to follow these regulations may harm
the environment and can lead to the imposition of substantial fines. Because these regulations may vary due to the passage of new laws we suggest that any work on this unit be done by a certified technician. Should you have any questions please contact the local EPA office. The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of any components, accessories or devices (other than those authorized by the manufacturer) into, onto, or in conjunction with the air conditioner. You should be aware that the use of unauthorized
components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or
injury resulting from the use of such unauthorized components, accessories or devices. Attach the service panel to the outdoor unit securely. If the service panel is not attached securely, it could result in a fire or an electric shock due to dust, water, etc.
Message to Owner
These instructions should be carefully read and kept near the product for future reference. While the instructions are addressed primarily to the installer, useful maintenance information is included. Have your installer acquaint you with the operating characteristics of the product and periodic maintenance requirements.
TABLE OF CONTENT
1.Introduction ---------------------------------------------------------------------------------------
2.Nomenclature for Model Number -------------------------------------------------------------
3.Specification -------------------------------------------------------------------------------------
4.Unit Inspection -----------------------------------------------------------------------------------
5.Equipment Protection From Environment ----------------------------------------------------
6.Installation ----------------------------------------------------------------------------------------
6.1. General ---------------------------------------------------------------------------------------
6.2.Unit clearances ------------------------------------------------------------------------------
6.3.Refrigerant piping ---------------------------------------------------------------------------
6.4.Electrical wiring -----------------------------------------------------------------------------
7.System Startup -----------------------------------------------------------------------------------
8.Operation ----------------------------------------------------------------------------------------
9.Miscellaneous -----------------------------------------------------------------------------------
9.1.Replacement parts --------------------------------------------------------------------------
9.2.Troubleshooting guide ---------------------------------------------------------------------
9.3.Wiring diagram -----------------------------------------------------------------------------
1 1 1 3 3 3 3 4
4 8 9 10 10 10 10 10
3.SPECIFICATION
The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical specifications are provided in Table 1.
Figure 1
H
W
1.INTRODUCTION
This manual contains the installation and operating instructions for your new air conditioner. Improper installation can result in unsatisfactory operation or dangerous conditions. Carefully read this manual and any instructions packaged with separate equipment required to make up the system prior to installation. Give this manual to the owner and explain its provisions. The owner should retain this manual for future reference.
2.NOMENCLATURE FOR MODEL NUMBER
1
D
X X X XX X X X
G= 9 SEER
H=Horizontal Flow Efficiency H= 10 SEER V=Vertical Air Flow J= 13 SEER
1= R22 2= 208/230V-1Ph-60Hz
3= 208/230V-3Ph-60Hz
First Generation Voltage 4= 220/240V-1Ph-50Hz
5= 380V-3Ph-50Hz 6= 380V-3Ph-60Hz
18= Capacity Btuh
Application C = Cooling
H= Heat Pump
Model:V1118-60C2H V1160C3H
Table 1:
2
V1160C3H V1160C2H V1148C2H V1142C2H V1136C2H V1130C2H V1124C2H V1118C2H
55000 56000 46000 40000 34000 28000 23500 18000
22.2 36 29 2521           18           14          10
45 60 45 400 35 30 25 20
Rated Load Amps 16.6 26.9 21.3 18.3 15.4 13.0         10.0 7.0
Lo
cked Running A
mps
134 149 130 130 92 73 60 43
Full Load Amps 1.43 1.43 1.40 1.40 1.40 1.40 0.86 0.86
Rated HP 1/3 1/3 1/5 1/5 1/5 1/5 1/8 1/8
Normal RPM 1100 1100 1100 1100 1100 1100 1000 1000
3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52]
7/8"[22.2] 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 5/8"[15.88] 5/8"[15.88]
120.14[3400] 102.47[2900] 95.41[2700] 77.74[2200] 77.74[2200] 70.67[2000] 56.53[1600]
30 1/4"*30 1/4"*27 3/4" 30 1/4"*30 1/4"*31 1/2"
[770*770*705] [770*770*805]
23"*23"*31 1/2"
[585*585*805]
23"*23"*27 3/4"
[585*585*705]
23"*23"*24"
[585*585*605]
23"*23"*24"
[585*585*605]
23"*23"*24"
[585*585*605]
23"*23"*24"
[585*585*605]
31 5/8"*31 5/8"*30 5/8" 31 5/8"*31 5/8"*34 5/8"
[804*804*780] [[804*804*880]
25" * 25 "* 32 1/2"
[636*636*825]
25" *25 "*28 1/2"
[636*636*725]
25" *25"*24 5/8"
[636*636*625]
25"*25"*24 5/8"
[636*636*625]
25"*25"*24 5/8"
[636*636*625]
25"*25"*24 5/8"
[636*636*625]
09[9]        216[98]       176[80] 165[75]     134[61] 133[60]128[58]      126[57]
220[100] 232[105]      191[87] 179[81]       146[66]146[66] 140[64]       138[63]
Net weight-Lbs(kg)
A
pprox shipping weight-Lbs(kg
)
Cooling Capacity (Btu/h)
TECUMSEH
Vapor Line OD-In(mm)
R-22charge-OZ[g]
Net Dimensions-in(mm)
W*D*H
Shipping Dimensions-in(mm)
W*D*H
Max fuse or Max CKT. BKR.
( HACR TYPE per NEC)
Compressor
Fan Motor
Liquid Line OD-In(mm)
Compressor Brand Sanyo
Sanyo
Minimum Circuit Amps
MODEL
Unit Supply Voltage 208/230-3-60
Normal Voltage Range 197-253
197-253
208/230-1-60
127.21[3600]
7/8"[22.2]
3/8"[9.52]
4.UNIT INSPECTION
This product has been inspected at the factory and released to the transportation agency without known damage. Inspect exterior of carton for evidence of rough handling in shipment. Unpack carefully. If damage is found, report immediately to the transportation agency.
5. EQUIPMENT PROTECTION FROM ENVIRONMENT
The metal parts of the unit may be subject to rust or corrosion in adverse environmental conditions. This oxidation could shorten the unit life. Salt spray or mist in seacoast areas, sulphur or chlorine from lawn watering systems and various chemical contaminants from industries such as paper mills and petroleum refineries are especially corrosive.
If the unit is to be installed in an area where contaminants are likely to be a problem, special attention should be given to the equipment location and exposure.
Avoid having lawn sprinkler heads spray directly on the unit cabinet. In coastal areas, locate the unit on the side of the building away from the waterfront. Shielding provided by fence or shrubs may give some protection.
Regular maintenance will reduce the buildup of contaminants and help to protect the unit's finish.
! WARNING - Disconnect all electrical power to the unit before servicing. Disconnect power to both the indoor and outdoor units. NOTE: There may be more than one electrical disconnect switch. Failure to shut off power can cause electrical shock resulting in personal injury or death.
Frequent washing of the cabinet, fan blade and coil with fresh water. Regular cleaning and waxing of the cabinet with good automobile polish. A good liquid cleaner may be used several times a year to remove matter that will not wash off with water.
The best protection is frequent cleaning, maintenance and minimal exposure to contaminants.
6.INSTALLATION
6.1.GENERAL
These units are designed for outdoor installations. They can be mounted on a slab or rooftop. It is important to consult your local code authorities at the time the first installation is made.
Check following points before attempting any installation:
Structural strength of supporting members. Clearances and provision for servicing. Power supply and wiring. Location for minimum noise, where operating sounds will not disturb owner or neighbors. Location where there is no risk of combustible gas leakage. Location where external water drainage cannot collect around the unit. Location where roof runoff water does not pour directly on the unit. Provide gutter or other shielding at roof level. Don't locate unit in an area where excessive snow drifting may occur or accumulate.
3