Haier HW-07LM03, HW-09LM03-HK, HW-12LM03-HK User Manual

ROOM AIR COMNDITIONER
OPERATION MANUAL
HW07M HW09M HW12M HW18M
Please read this operation manual before using the air conditioner
Please keep it attentively
0010517091
CONTENTS
Safety precautions...................1
Air conditioner operation..........2
Care and Maintenance ............4
Air conditioner installation........5
Troubleshooting.......................7
1
SAFETY PRECAUTION
Do not install,remove and reinstall the unit yourself.
leakage,electric shock or fire.Please engage an authorized dealer or specialist for the installation work.
The room air conditioner must be earthed. Do not touch or operate with wet hands. Do not turn on the unit by inserting the power plug.Do not switch off the unit by pulling out the power plug.
Do not insert sticks,fingers or other objects into the unit.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. After installation, the power plug should be easily reached.
The wiring method should be in line with the local wiring standard.
OPERATION CONDITIONS
Improper installation may cause
CAUTION
Operation panel
Auto swing switch
1
HW07M HW09M HW12M
Thermostat switch
2
This switch controls the preset indoor temperature to make the air conditioner start or stop automatically, so as to reduce power consumption and operate the system both comfortably and economi­cally.
The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature.
CAUTION
Switch off the breaker and set the main control knob to the off position before plugging the power plug into an electrial outlet. In cooling mode, after you turn thermostat switch counter-clockwise,do not turn it back until at least 3 minutes have elapsed.Otherwise, the fuse may blow due to overload. Do not exceed the selection range.
6
5
7
4
8
3
9
2
10
1
HW18M
Mode selection switch
3
Applicable ambient temperature range:
Cooling
Max.Temperture:
Min.Temperture:
2
AIR CONDITIONER OPERATION
Indoor
W.B
D.B D.B
o
23 C
o
o
32 C
18 Co14 C
Outdoor
W.B
43 Co26 C
18 Co/
o
PART INDENTIFICATION
Machine body
Front panel
Air inlet (indoor side)
Air filter (inside)
Operation
panel
Ventilation
Power plug
Air filter cleaning
2
When dirt accumulates on air filter, air circulation will be blocked, which causes poor cooling. It is advisable to clean air filter every two weeks for longer operation.
Take out the air filter
1.Press the concave parts on both sides at the lower part of air inlet grille to open the air inlet grille.
2.Hold the hump of filter mesh with fingers (as illustrated) and take it out.
Clean the filter
1.Gently flap the dirt off the air filter.
2.Carefully wash air filter in warm water(below 40°CTo obtain better cleaning effect,soap water or neutral detergent may be used.
3.Flush air filter carefully with clean water after removing dirt.Let it dry completely.
Hump
Air outlet (indoor side)
Machine body
Air inlet
(outdoor side)
CAUTION
Before cleaning, turn off the power Do not raise the front panel any higher than 70° to the unit or damage to the tabs may occur.
70
°
D.B :Dry Bulb Temperature
W.B :Wet Bulb Temperature
Ventilation
1
OPENCLOSE
The ventilation lever must be CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is exhausted.
Airflow Direction
3
Airflow Direction Vane
The Vertical Airflow Direction Vane is manually controlled by positioning the vane to discharge the air upward,downward or straight out.
Vertical
airflow direction
The horizontal air direction is adjusted by setting the AUTO SWING switch to the ON position.
Note:
It is advisable not to keep horizontal flap at downward position for a long time in COOLor FAN mode,otherwise , condensate water might occur.
Don't move the vertical flap with hand in order to avoid the vertical flap abnormal, using the
AUTO SWING switch to adjust the move of vertical flap.
1
3
2
4
3
CARE AND MAINTENANCE
Air filter cleaning
1
It is advisable to clean air filter every two weeks for longer operation. (You will find how to clean the filter on page 2 .)
Notes
2
Avoid opening doors and windows unless necessary.
Use curtain or blind Direct sunlight may reduce cooling effect, always use window curtain.
Don't hang clothes in the vicinity of air inlet. This will decrease cooling effect and cause abnormal operation.
Always turn off the air conditioner and the main power supply before clean the unit. Switch off the power supply if the unit is not going to be used for a long period of time.
Cleaning of the
air filter
Don't be exposed to cold air for a long time.
Keep heat source away from air conditioner.
Temperature should be set properly when there are infant,child, the aged or disabled in the room.
Baby has gone sleep, better to adjust suitable temp.
Set temp . a little bit higher before going to bed.
Proper temperature
After unit stops, don't restart it until 3 min. have elapsed.
OK! Enjoy a 3-min nap
Before operating mode selection switch, check that if the air inlet or outlet have been blocked.
4
AIR CONDITIONER INSTALLATION
SELECTION OF THE INSTALLATION POSITION
1,The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is recommended that air-conditioner be installed at least at the height of 760-1300 mm above the floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of air-conditioner should be protruded outdoors free from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept over 500mm from the obstacles (for example, wall, etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of the air-conditioner should be inclined downward by 5-10mm (As illustrated in Fig. 3).
>500mm
cover
fig.2
(ONLY FOR REFERANCE)
support
INSTALLATION PROCEDURES
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed,
on the iron frame. If there's water outlet flexible pipe, lead it to needed position(see Fig.1).
fig.1
3. Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to
5-10mm
prevent the entering of outer noise and the leaking of the coolness.
4. After installation of the conditioner, insert the power plug into the outlet and perform test-run.
fig.3
Wall
Water outlet flexible pipe(provide by user)
Fig.1
NOTES:
For longer and trouble-free operation of the unit, pay special attention to the following:
Install air-con at a place strong enough to support the unit. Leave enough space around air inlet and outlet for better circulation. Avoid places where flammable gas leaks. Problems may occur if unit is installed in the following places: Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air.
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
Name
Figure
Quantity
Rubber lid
11114
Manual
Drain pan
Sealed gasket
PREPARATIONS BEFORE INSTALLATION
Make the wall hole or window hole (see Fig.1)
MODEL A B
HW07M HW09M
HW12M
HW18M
Prepare unit for installation:
370mm 485mm
395mm 615mm
440mm 635mm
A
B
Fig. 1
Iron frame
Width of the wall
Screw
Cautions
5
TROUBLESHOOTING
5
7
6
8
Phenomenon SolutionCause or check points
Switch on the machine but it does not work immediately.
Power cord: Be sure to use the exclusive power cord. Change installation place: If air-con need to be changed to another place please contact the dealer, who sold you the unit. Always use at the rated voltage and with specfic air conditioning circuit
Before calling for service.
Check the following points before calling for repairs or service.
If the machine is started after stop,it will need about 3 minutes to re-start so as to prevent the fuse from break.
1.Take out the conditioner and accessories from the package .
2.Disposal of the condensed water.
Install
Drain pan
make the condensed water flow out from the bottom plate. (See Fig.1) If necessary the above method can have extra pipe added on the (available on the market).
to the bottom hole.which can
Drain pan
Cautions
To ensure the safty in transportation, some machines are fixed paper guard by the side of the machine (as figure shows).Please check and remove the paper guard first before you fixed your machine.
Condenser
Fig.1
Bottom plate hole
Drain pan
Paper guard
Screw
Switch on the machine but it does not work.
The cooling effect is not good.
Is plug firmly inserted? Is there power failure?
Does fuse get burned?
Is thermostat switch wrongly adjusted?
Is there any direct sunlight in the room?
Are doors or windows left open?
Are there any obstacles blocking air inlet and outlet?
Is air filter clogged?
Is there too much heat source in the room?
Readjust power supply
Replace fuse.
Readjust the thermostat.
Use curtain or blind.
Shut doors and windows.
Remove the obstacles.
Clean it.
Remove the heat source
If problems can not be solved please pull out power plug and contact your dealer.