ROOM AIR CONDITIONER
HW-05LMA13
0010563803
his air conditioner contains R410a refrigerant and requires certified technicians to use the proper
T
equipment,
certified
rom the air conditioner prior to its disposal.
f
tools and safety standards that are approved for this refrigerant. Use only equipment
for R410a refrigerant. In addition, under federal law, all refrigerant must be properly removed
T4
4
3
2
1
MIN
COOL
ON OFF
Wait 3 Minutes
Before Restarting
5 6
4
3
6
5
7
8
9
10
MAX
COOL
FAN ONLY
SPEED
LOWHI
POWER
2
COOL
MIN
FAN ONLY
7
MAX
COOL
8
9
101
SPEED
LOWHI
POWER
ON OFF
Wait 3 Minutes
Before Restarting
POWER
The Power switch turns the air conditioner on or off.
NORMAL FAN
Press the SPEED switch to either HI or LOW
Set the thermostat control to the FAN ONLY setting
NORMAL COOL
Press the SPEED switch to either HI or LOW
Set the thermostat control to the desired temperature
setting. If the room is not satisfactory after a
reasonable amount of time, adjust the thermostat
control to the appropriate setting to meet your needs.
MAX COOL
Press the SPEED switch to HI.
Set the thermostat control to MAX COOL mark.
QUIETER OPERATION
Press the SPEED switch to LOW
Set the thermostat control as needed.
28
Do not try to operate your air conditioner in the Cool mode when outside temperature is
below 18°C. The inside evaporator coil will freeze up, and the air conditioner will not
operate properly.
1. Turn off the air conditioner.
2. Grasp the filter handle and pull the filter out.The filter will
slide out easily.
3.
4.
5.
The air directional louvers
let you control the direction
of the airflow. The airflow
can be directed left to right.
4
AIR CONDITIONER INSTALLATION
SELECTION OF THE INSTALLATION POSITION
(ONLY FOR REFERENCE)
5
TROUBLESHOOTING
Before calling for service.
Check the following points before calling for repairs or service.
1,The air-conditioner is better installed in shadow or in a place
with short period of sunshine. In case the air-conditioner is
installed at the point exposed directly to the sunshine, it should
be protected from the direct sunlight as possible in order to
avoid the long time of direct sunlight otherwise its performance
will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is
recommended that air-conditioner be installed at
least at the height of 760-1300 mm above the
floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of
air-conditioner should be protruded outdoors free
from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept over
500mm from the obstacles (for example, wall,
etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of
the air-conditioner should be inclined downward
by 5-10mm (As illustrated in Fig. 3).
>500mm
cover
support
fig.2
NOTES:
For longer and trouble-free operation of the unit, pay special attention to the following:
Install air-con at a place strong enough to support the unit.
Leave enough space around air inlet and outlet for better circulation.
Avoid places where flammable gas leaks.
Problems may occur if unit is installed in the following places:
Place where oil exists in the air including engine oil or seaside with
salt breeze blows and hot spring area with sulphurous gas in the air.
5-10mm
fig.1
fig.3
Phenomenon SolutionCause or check points
Switch on the machine but it
does not work immediately.
Switch on the machine but it
does not work.
The cooling effect is not good.
If the machine is started after stop,it will need about 3 minutes
to re-start so as to prevent the fuse from break.
Is plug firmly inserted?
Is there power failure?
Does fuse get burned?
Is thermostat switch
wrongly adjusted?
Is there any direct
sunlight in the room?
Are doors or windows
left open?
Readjust power supply
Replace fuse.
Readjust the thermostat.
Use curtain or blind.
Shut doors and windows.
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
Name
Figure
Manual
PREPARATIONS BEFORE INSTALLATION
Make the wall hole or window hole (see Fig.1)
Iron frame
MODEL A B
HW-05LMA13
334mm 440mm
A
B
Are there any obstacles
blocking air inlet and
outlet?
Is air filter clogged?
Is there too much heat
source in the room?
5
7
6
8
Remove the obstacles.
Clean it.
Remove the heat source
If problems can not be solved please pull out power plug and contact
your dealer.
Width of the wall
Prepare unit for installation:
Take out the conditioner and accessories from the package .
Fig. 1
INSTALLATION PROCEDURES
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed on the iron frame.
3. Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to
prevent the entering of outer noise and the leaking of the coolness.
4. After installation of the conditioner, insert the power plug into the outlet and perform test-run.
Cautions
Power cord: Be sure to use the exclusive power cord.
Change installation place: If air-con need to be changed to another
place please contact the dealer, who sold you the unit.
Always use at the rated voltage and with specfic air conditioning circuit