Haier HSU-18LEB03 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
PAS24L03-N(T3) PAS30H03-N(T3) ASM30H03-N(T3) HSU-32LEA13-W HSU-24HEA03(T3) HSU-24HEA13(T3) HSU-24LEA13(T3) HSU-24LEA03(T3) HSU-24LEA03-T HSU-30HEA03(T3) HSU-30HEA13(T3) HSU-24LEB03(T3) HSU-36LEA03(T3) HSU-18LEB03(T3) HSU-30LEA13(T3) HSU-28LEA03(T3) HSU-30LEA03(T3)
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
1 2-4
5
HSU-30HEA03 HSU-24HEA03 HSU-24LEA03 HSU-24LEA13-M HSU-26HEA03
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010518784
POWER/SOFT
Parts and Functions
If the unit which you purchased has
SWING LEFT/RIGHT
function,follow it.If not,please ignore.
Indoor Unit
1
2
3
7
5
1
1
Inlet
2
2
Inlet grille
3
3
Air Purifying Filter (inside)
5
4
Outlet
Actual inlet grille may vary from the one shown in the manual according to the product purchased
8
Display board
3
1
1
Signal receiver hole
HEALTH display
2
(If the unit which you purchased
has healthy function,follow it.
If not,please ignore.)
3
TIMER OFF display
TIMER ON display,SLEEP display
Ambient temp.display
4
2
4
5
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
6
6
Vertical blade
(adjust left and right air flow)
7
Anion generator
4
(When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.)
5
AUTO display
6
COOL display
Dry display
7
HEAT display
8
6
5
7 8
(inside)
Remote controller
6. HEALTH button
Used to set healthy operation.
7. MODE button
19
8. HOUR button
Used to set clock and timer setting.
SWING button
9.
Used to select up or down air sending direction.
. ON/OFF button
10
Used for unit start and stop.
11. TIMER ON display
12. FAN SPEED display
4
5
6 8
POWER/SOFT
1.CODE
Used to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation.
2.RESET
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
4. TIMER button
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
28
30
LOW HI
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
17. Operation mode display
Operation mode
Remote controller
Display board
18.Signal sending display
19. POWER/SOFT display
20. Left/right air flow display
21. TEMP display
Remote controller: to display the TEMP. setting.
22. TIMER OFF display
23. CLOCK display
24. TEMP button
Used to select your desired temperature.
25. FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
26. HEALTH AIRFLOW button
Used to set the health airflow mode.
27. SLEEP button
Used to select sleep mode.
28. SET button
Used to confirm timer and clock settings.
29. POWER/SOFT button
Use to set power/soft function.
30. LOCK
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition
display appears. Press it once again, lock will be cancelled and lock condition display disappears.
AUTO COOL DRY FAN HEAT
MED AUTO
AUTO
COOL DRY
HEAT
FAN
Outdoor Unit
OUTLET
INLET
CONNECTING PIPING
4
Loading of the battery / Clock set
Remove the battery cover;
1
2
Load the batteries as illustrated.2 R-03
2
batteries, resetting key (cylinder);
1
Be sure that the loading is in line with the" + "/"-";
3
Load the battery,then put on the cover again.
Note:
3
The distance between the signal transmission head and the
receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals, so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the batteries have been used up.Please change batteries.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
4
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept pressed,time will change quickly. After time setting is confirmed,press SET,"AM "and "PM" stop flashing while clock starts working.
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
1
after taking-out, just need to press reset key
AND ELECTRICAL WIRING
14
DRAIN HOSE
8. HOUR button
Used to set clock and timer setting.
9. HEALTH button
Used to set healthy function.
10. ON/OFF button
Used for unit start and stop.
11. TIMER ON display
12. FAN SPEED display
LOW HI
MED AUTO
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
17. Operation mode display
Operation mode
Remote controller
Display board
18.Signal sending display
19.POWER/SOFT display
20. Left/right air flow display
21. TEMP display
Remote controller: to display theTEMP. setting.
22. TIMER OFF display
23. CLOCK display
24. TEMP button
Used to select your desired temperature.
25. FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
26. HEALTH AIRFLOW button
Used to set the health airflow mode.
27. SWING UP/DOWN button
Used to select up or down air sending direction.
28. SWING LEFT/RIGHT button
Used to select left/right air flow.
29
FRESH
Use to set fresh air function. (This function is unavailable on this models.)
30
SET button
Used to confirm timer and clock settings.
POWER/SOFT button
31.
Used to set power/soft function.
LOCK
32.
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
button
AUTO
COOL DRY
HEAT
FAN
FRESH
POWER/SOFT
1.CODE
Used to select CODE A or B with a press, A or B will be displayed on LCD.
Please select A without special explanation.
2.RESET
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
4. TIMER button
Used to select TIMER ON, TIMER OFF,TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
6. SLEEP button
Used to select sleep mode.
7. MODE button
AUTO COOL DRY
HEAT
FAN
19
28
NOTE:
Cooling only unit do not have displays and functions related with heating
If the unit which you purchased has healthy function,follow it.If not,please ignore.
Operation
Unit start / stop
Press ON/OFF button, unit starts or stops.
Select temp.setting
Operation Mode
AUTO
COOL
DRY
HEAT
FAN
Display Board
nothing
Remote Controller
Note
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner according to room
In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
When FAN is set to AUTO, the
automatically adjusts the fan speed
temperature.
o
C,unit will run intermittently
Cool Operation
Dry Operation
Auto Operation
According to the automatic choice system in temperature
in indoors cold or make the hot movement.
Heat Operation
Note:
In HEAT mode,warm air will blow out after a short periodof the time
due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts
the fan speed according to room temperature.
Cooling only unit do not have displays and functions related with heating
Fan Operation
1.
When FAN is set to AUTO,
the air conditioner
automatically adjusts
the fan speed according
to room temperature.
2.In FAN operation mode the unit will not operate
in COOL mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
AUTO LO MED HI
Note:
In DRY mode,when room temperature becomes lower than temp.setting
0
+2 C, unit will run intermittently at LOW speed regardless of FAN setting.
Air Flow Direction Adjustm
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
FRESH
Pos.6
(Auto
swing)
FRESH
Horizontal louvers
(This function is unavailable on some models.)
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
Health airflow Operation
The setting of health airflow function
1).Press the button of health airflow, appears on the display. Avoid the strong airflow blows direct to the body.
2).Press the button of health airflow again,
appears on the display. Avoid the strong
3.The cancel of the health airflow function Press the button of health airflow again, both the inlet and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the setting of health airflow function. After stopping, the outlet grille will close automatically. Notice: Cannot pull direct the outlet grille by hand. Otherwise,the grille will run incorrectly. If the grille is not run correctly,stop for a minute and then start, adjusting by remote controller.
Note:
1 .After setting the health airflow function, the position of inlet and outlet grills is fixed.
2.In heating, it is better to select the mode.
3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille .
5.Select the appropriate fan direction according to the actual conditions.
Remote controller can memorize each operation status. When starting it next time,just press ON/OFF button and unit will run in previous status.
strong airflow blows direct to the body.
2
Loading...
+ 5 hidden pages