Haier HSU-09HEG03/DB, HSU-12HEG03/DB, HSU-18HEG03/R2, HSU-18HEG03/DB, HSU-24HEG03/R2 Operation Manual

...
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITIONER OPERATION MANUAL
0010538410
HSU-09HEG03/R2(DB)
Contents
PARTS AND FUNCTIONS OPERATION
MAINTENANCE CAUTIONS
TROUBLE SHOOTING
HSU-12HEG03/R2(DB) HSU-18HEG03/R2(DB)
HSU-24HEG03/R2(DB)
HSU-09HEK03/R2(DB) HSU-12HEK03/R2(DB)
HSU-18HEK03/R2(DB)
HSU-24HEK03/R2(DB)
Outdoor Unit
Loading of the battery
1 2
3
4
Parts and Functions
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote controller
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
Please be subject to the actual produce purchased the above picture is just from your reference
4
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
Please be subject to the actual produce purchased the above picture is just from your reference
1. Mode display
2. Signal sending display
4. FAN SPEED display
5. LOCK display
6. TIMER OFF display TIMER ON display
LO MED HI
7.TEMP display
16. LOCK button
Used to lock buttons and LCD display.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote
22. HOUR button
Operation mode
AUTO FANCOOL DRY
Remote controller
HEAT
1
2
3
4
5
9
10
11
12
13
14
15
16
17
22
23
24
25
19
20
21
8
18
7
6
Control the lightening and extinguishing of the indoor LED display board.
3. SWING display
8
.
9. QUIET button
10. HEAT button
11. COOL button
12. AUTO button
13. FAN SPEED button
14. TIMER button
15. HEALTH button
17. LIGHT button
18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
AUTO
Function: Setting and cancel to the timer and other additional functions.
Display circulated
Operation mode
Remote controller
QUITE
POWER
SLEEP
Supplemented electrical heating
HEALTH
Additional functions display
Healthy function is not available for some units.
Function: Air sending--- Healthy airflow position1--- Healthy airflow position 2 --- Restore the original flap position --- Right & left air airflow
--- A-B yard---10 and heating symbol displayed simultaneously--- Sleeping
--- Electrical heating--- Refresh air (
reserved function) --- Power ---
Fahrenheit/Celsius mode conversion
Air Purifying Filter(inside)
Inlet
1
Inlet grille
2
Outlet
4
(adjust left and right air flow)
Vertical blade
6
Display board
Horizontal flap
(adjust up and down air flow.
Don't adjust it manually)
Emergency
Switch
7
8
3
5
1
2
4
6
5
7
3
1
EK3
8
1
2
3
4
5
8
6
7
EK1 display board
EK3 display board
Display board
When receiving the remote control signal,display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
Signal receiver hole ON/OFF display Ambient temp.display
TIMER ON/OFF display TIMER ON-OFF display SLEEP display
Note to the power failure resume:
Press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after hearing two sounds.
EK1
COOL\HEAT\DRY\AUTO display
4
5
4
5 6
RUNNING display
2
4
6
Operation
Air Flow Direction Adjustment
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment
(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency operation and test operation
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
changes as
Operation
Mode
Remote
Controller
Note
In DRY mode , when room temperature becomes lower than temp.setting+2
o
C, unit will run intermittently at LOW
speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature.
In FAN operation mode , the unit will not operate in COOL or HEAT mode but only in
FAN mode, AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available.
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Designated temperature
Timer mode
Fan
speed
Operation
mode
Above 23oC
Below 23
o
C 23oC
26
o
C
No
AUTO
AUTO
COOL
HEAT
No
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test ope ratio n switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
LOW
MED HI
AUTO
2. Select operation mode
COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode
Display
circulated
DRY
COOL
AUTO
HEAT
FAN
In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
test operation
switch
Pi
Pi
Pi
emergency
operation switch
'
2
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
cooling mode:from pos.1 to pos.4 and pos.6 heating mode:from pos.5 to pos.1 and pos.6