Haier HSU-18HEA03, HSU-18LEA03, HSU-18LEA13 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HEA03 HSU-12HEA03 HSU-12HEB03 HSU-18HEA13(T3)
HSU-18HEA03(T3) HSU-18LEA13(T3)
HSU-18LEA03(T3)
Please read this operation manual before using the air conditioner.
0010522564
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inop­erative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1.Applicable ambient temperature range:
For: 220-230V~, 50Hz
o
32
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B
Maximum:D.B Minimum:
Maximum: Minimum:D.B
For: 220V~, 60Hz
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
D.B
D.B/W.B
C/23oC
o
18
C/14oC
o
C/31oC
52
o
18
C
o
27
C
o
C
15
o
C/18oC
27
o
C
-7
29oC/19oC 18oC/14oC
54oC/24oC 18oC
27oC 15oC
24oC/18oC
-7oC/-8oC
2. If the power supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of
T. 3.15A/ 250V.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use
by young children or infirm persons
without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug, which fit into the power supply cord.
10 .The power plug and connecting cable
must have acquired the local attestation.
11.In order to protect the units,please turn
off the A/C first, and at least 30 seconds later, cutting off the power.
2
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth cable.
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
PROHIBITION PROHIBITION
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
STRICT ENFORCEMENT
Cautions
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
WARNING
Use an exclusive power source with a circuit breaker
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not use power supply cord
extended or connected in halfway
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
4
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
Parts and Functions
Indoor Unit
Display board
Inlet
Air Purifying Filter
(inside)
Inlet grille
Horizontal flap (adjust up and down air flow. Don't adjust it manually)
Anion generator
(inside)
Actual inlet grille may vary from the one shown in the manual according to the product purchased
(adjust left and right air flow)
Outlet
Vertical blade
Outdoor Unit
Air filter(inside)
Power plug
HSU-12HEB03
OUTLET
INLET
HSU-18HEA13(T3) HSU-18HEA03(T3) HSU-18LEA13(T3) HSU-18LEA03(T3)
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
5
HSU-09HEA03 HSU-12HEA03
Loading...
+ 14 hidden pages