Haier HSU09VHK(DB), HSU12VHJ(DB), HSU24VHK(DB), HSU18VHJ(DB) Operation Manual

0010526878
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITIONER OPERATION MANUAL
....................................................
1 2
3
......................................................................
6
..........................................................
7
PARTS AND FUNCTIONS OPERATION MAINTENANCE
TROUBLE SHOOTING
CAUTIONS
Contents
....................................................
....................................................
1
....................................................................
9
................................................................
10
......................................................................
13
..........................................................
14
Índice
PRECAUCIONES
COMPONENTES Y FUNCIONES
FUNCIONAMIENTO
MANTENIMIENTO
RESOLUCIÓN DE PROBLEMAS
....................................................
1
....................................................................
16
................................................................
17
......................................................................
20
..........................................................
21
Table des matières
AVERTISSEMENTS PIÈCES ET FONCTIONS OPÉRATION MAINTENANCE
DÉPANNAGE
HSU18VHJ(DB)
HSU12VHJ(DB)
HSU09VHK(DB)
HSU24VHK(DB)
Outdoor
Unit
Loading of the battery
1
2
3
4
Parts and Functions
Indoor Unit
Actual inlet grille may vary from the one shown in the manual according to the product purchased
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote controller
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
Inlet grille
Inlet
Air Purifying Filter
Outlet
Horizontal flap
Display board
(adjust up and down air flow
Don't adjust it manually)
(adjust left and right air flow)
Vertical blade
Emergency
Switch
Anion generator
(inside)
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be sho
rter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
rem
ove the batteries and
Hint:
Operation mode
AUTO
FAN
COOL DRY
Remote controller
HEAT
LOW HI
MED AUTO
If pressed, the other buttons will be disabled. Press it once
again,lock will be cancelled.
30
.
LOCK
button
When the remote
RESET
button
controller appears abnormal, use a sharp
pointed article to press
this button to reset the
1
.
Control the lightening and
the indoor
extinguishing of
LED display board.
remote controller normal.
2.LIGHT button
3. TIMER button
4. CLOCK button
8. HEALTH button
6. MODE button
7. HOUR button
9. ON/OFF button
10. TIMER ON display
11. FAN SPEED display
12. LOCK display
13. SWING UP/DOWN display
14. SLEEP display
15. HEALTH display
16. Operation mode display
17
.Singal sending display
18. POWER/SOFT display
19. Left/right air flow display
20. TEMP display
21. TIMER OFF display
22. TIMER display
23. TEMP button
24. FAN button
25. HEALTH AIRFLOW button
26. SWING UP/DOWN button
27. SWING LEFT/RIGHT button
5. SLEEP button
28. SET button
29. POWER/SOFT button
2
NOTE:
30
28
19
F
AB
UsetoselectCODEAorBwhich will be displayed on LCD. Please select A without special explanation.
31
.
CODE
button
CODE
31
C
.5
Cooling only units do not have the functions and displays related with heating. The following functions and related displays are not available:
Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
4
Display board FOR:09K 12K
F
F
TEMP display
COOL display
HEAT display
HE
ALTH display
Dry display
TIMER ON/TIMER OFF display SLEEP display
AUTO display
Remote signal receiver
Display board FOR:18K
Display board FOR:24K
3
Operation
Air Flow Direction Adjustment
AUTO COOL DRY FAN HEAT
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Select a desired temperature.
4.Fan speed selection
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
LOW
MED
HI
AUTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
Operation
Mode
AUTO
Display Board
Remote
Controller
Note
COOL
DRY
HEAT
FAN
nothing
In DRY mode, when room temperature becomes lower than temp.setting about +4
o
F,unit will run
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner
automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment
(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occu
r.
conditioner
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
intermittently
POWER/SOFT
temperature is below 60
o
F, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation switch for more than 5 seconds. After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Pi Pi
Emergency Operation:
Emergency operation and test operation
Pi
Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or fan or heat, according to the room temperature.
When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, it can't operate for dehumidifying or under timing mode.
Press
button
Every time the button is pressed, temp.setting increas
e2
o
F,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 2
o
F,if kept depressed, it will decrease
rapidly
3.Select temp.setting
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
change quickly.
After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
or decrease 1min. If the
button is kept pressed,time will
will increase
POWER/SOFT
F
CODE
Operation
Sleep Operation
If the fan speed is high or medium before setting for the sleep, set for low speed after sleeping.
Note to the power failure resume: press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds. NOTE: With the power failure resume, when setting the TIMER ON, TIMER OFF and TIMER ON/OFF, it’s memorized as shutdown status when resuming after power out
.
5. Set the fan speed change when sleeping
Before going to bed, you can simply press the SLEEP
button and unit will operate in SLEEP
mode and b
ring you a sound sleep.
Use of SLEE
P function
After the unit sta
rts, set the operation status,
then press SLEEP
button before which the
clo
ck must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
beco
me about 2
O
F higher than temp.setting.
A
fter
another 1 hour
s, temp. rises
about 2
The unit will
run for further 6 hours then stops
Temp. is higher than temp. setting so that room
tempe
rature won't be too Iow for your sleep.
SLEEP operation starts SLEEP operation stops
SLEEP ope
ration starts
SLEEP ope
ration stops
Approx.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises about 2
O
F
Rises about 2
O
F
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HE
AT mode
Decreases about 4OF
1 hr
2.
3.
In HE
AT mode
1 hours after SLEEP mode sta
rts, temp
will become about 4
O
F lower than temp.
setting
. After another 1 hours, temp
decrease about 4
O
F further. After more
another 3 hour
s, temp. rises about 2
O
F
fu
rther. The unit will run for further 3
hours then stop
s. Temp. is lower than
tem
p. setting so that room temperature
won't be too high for your sleep.
In
AUTO mode
The unit ope
rates in corresponding sleep mode adapted to the automatically selected ope
ration mode.
4. In FAN mode It has no SLEEP function.
POWER/SOFT Operation
(1)
POWER Operation
(2)
SOFT Operation
4
When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medium speed of AUTO fan mode.
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed
automatically takes low speed
of AUTO fan mode.
Note˖ During POWER operation, in rapid HEAT or COOL modethe room will show uniform temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation Press POWER/SOFT button again, POWER or SOFT
disappears.
6.
HEALTHY Operation
Healthy Negative ions
The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
O
F further.
Rises about 2OF
Decreases about 4OF
5
Operation
Healthy airflow Operation
Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing.
5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function,when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Timer On/Off On-Off Operation
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
1).Press the button of healthy airflow
, appears on the
display. Horizontal airflow sending.
Avoid the airflow
blows direct to the body.
2).Press the button of healthy airflow again, appears on the displa
y
. Downward airflow sending.
Avoid the airflow
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may occur at the grille .
3.The cancel of the healthy airflow function
Press the button of healthy airflow again,
the unit
goes on
working under the condition before the setting of healthy
airflow function.
Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote controller.
blows direct to the body.
2.In heating, it is better to select the
3.In cooling, it is better to select the
mode.
mode.
3.Press HOUR button to set time.
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Close doors and win
dows
during operation
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not
block the air inlet
or outlet
Proper temperature
During cooling operation prevent the penetration of direct sunlight with curtain or blind
OFF
Air Filter cleaning
Open the inlet grille by pulling it upward.
Rem
ove the filter.
Clean the filter.
Attach the filter.
Close the inlet
grille.
Push up the filter's center tab slightly until it is released from the stoppe
r, and remove the filter downward.
Use a vacuum cleaner to rem
ove dust, or wash the filter with
water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fi
xed behind the stopper.If the right and left filters are not
attached correctly, that may cause defects.
Remote Controller
Do not use the
following for cleaning
Do not use water wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Gasolin
e,benzine, thinner or cleanser may
damage the coating of the unit.
Hot
water over 40
O
C(104OF) may cause
discolo
ring or deformation.
Wipe the air conditioner
by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth be
fore wiping.then wipe off
the detergent completel
y.
Indoor Body
Once every two weeks
1.Open the lnlet Grille
2.Detach the standard air filter
3.Attach Air Purifying Filter
4.Attach the standard air filter
(Necessary installation)
5.Close the Inlet Grille
Close the Grille surely
Slide the knob slightly upward to release the filter, then withdraw it.
Put air purifying filter appliances into the right and left filter frames.
Detach old Air Purifying Filter
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
it will be solarized every 6 months.
Prop up the inlet grille by using a
small device named grille-support
ATTENTION: The white side of the photocatalyst air purifying
filter face outside,
and the black side face the unit.
The green side of the bacteria-killing medium air
andthewhitesidefacetheunit.
Please keep the bacteria-killing medium air purifying filter in
avoid long time directly sunshine
when you stop using it,or its ability of sterilization will
be
reduced.
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
Replacement of Air Purifying Filter
which located in the right side of the indoor unit.
purifying filter face outside,
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
the cool and dry conditions
6
7
the power supply cord and so on.
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner
by yourself because improper works
may cause electric shock, fire, water leakage.
Connect the earth cable.
earthing
WARNING
When abnormality such as burnt-smell found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper vol
tage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
1.Do not use power supply cord extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the
operation by disconnecting
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
STRICT ENFORCEMENT
Check proper installation of the drainage securely