Haier AS24ZE1HAA, HSU-18LXAT3, HSU-18HXA03, HSU-18HXT3, HST-24LXA13 Operation Manual

...
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
0010560207
Contents
1 2-4
5
7
6.7
CAUTIONS
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
TROUBLE SHOOTING
HSU-18LXA03(T3)
AS24ZE1LAA
AS24ZE2LAA
AS24ZE1HAA
HSU-18HXA03(T3)
HST-24LXA13(T3)
HST-24HXA13(T3)
HST-18LXA13(T3)
HST-18HXA13(T3)
HSU-18HXA03
HSU-18LXA03
HSU-12HXA03
HSU-12LXA03
HSU-09HXA03
HSU-09LXA03
HSU-12LZE14
HSU-18LZE14
HSU-09LZE14
AS09ZB1LAA
AS12ZB1HRA
AS09ZB1HRA
AS18ZD3HAA
HSU-18HXAR(R2DB)
HSU-18HZE/R2(DB)-DC inverter
HSU-12HZE/R2(DB)-DC inverter
HSU-09LXA03-Y3HSU-18LXA13(T3)
HSU-18HXA13(T3)
HSU-19CXAG3
HSU-19CXAR5
HSU-19CXAS3
HSU-19CXBW3
HSU-13CXAG3
HSU-13CXAR5
HSU-13CXAS3
HSU-13CXBW3
1
Parts and Functions
Remote controller
Indoor Unit
Outdoor Unit
4
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Display board
(adjust left and
ow)
Vertical blade
r
ight air fl
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Outlet
Inlet grille
Display board
Display board
Signal receiver hole
COOL display
HEALTH display
4
2
3
1
5
DRY display
6
Ambient temp.display
When receiving the remote control signal, display the set temperature.
1. Mode display
2. Signal sending display
4. FAN SPEED display
5. LOCK display
6. TIMER OFF display TIMER ON display
LO MED HI
7.TEMP display
16. LOCK button
Used to lock buttons and LCD display.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote
22. HOUR button
Operation mode
AUTO FANCOOL DRY
Remote controller
1
2
3
4
5
9
10
11
12
13
14
15
16
17
22
23
24
25
19
20
21
8
18
7
6
Control the lightening and extinguishing of the indoor LED display board.
3. SWING display
8
.
9. TURBO button
10. FAN button
11. COOL button
12. AUTO button
13. FAN SPEED button
14. TIMER button
15. SLEEP button
17. LIGHT button
18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
AUTO
Function: Setting and cancel to the timer and other additional functions.
Display circulated
Operation mode
Remote controller
QUIET
TURBO
SLEEP
HEALTH
Additional functions display
NOTE: Healthy function is not available for some units.
Function: Health--- Healthy airflow position1--- Healthy airflow position 2
--- Restore the original flap position--­Right & left air airflow--- A-B yard---
Refresh air(
reserved function)--- QUIET
--- Fahrenheit/Celsius mode conversion
Remote controller A
1. Mode display
2. Signal sending display
4. FAN SPEED display
5. LOCK display
6. TIMER OFF display TIMER ON display
LO MED HI
7.TEMP display
16. LOCK button
Used to lock buttons and LCD display.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote
22. HOUR button
Operation mode
AUTO FANCOOL DRY
Remote controller
HEAT
Remote controller B
Remote controller B
1
2
3
4
5
9
10
11
12
13
14
15
16
17
22
23
24
25
19
20
21
8
18
7
6
Control the lightening and extinguishing of the indoor LED display board.
3. SWING display
8
.
9. TURBO button
10. HEAT button
11. COOL button
12. AUTO button
13. FAN SPEED button
14. TIMER button
15. SLEEP button
17. LIGHT button
18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
AUTO
Function: Setting and cancel to the timer and other additional functions.
Display circulated
Operation mode
Remote controller
QUIET
TURBO
SLEEP
Supplemented electrical heating
HEALTH
Additional functions display
Function:
Health--- FAN---
Healthy airflow
position1---
--- Healthy airflow position 2--­Right & left air airflow--- A-B yard---
function
)-- QUIET--- Refresh air(
reserved
--- Fahrenheit/Celsius mode conversion
HEAT
Low-Temperature Heating Operation Down to 10
Actual inlet grille may vary from the one shown in the manual according to the product purchased
(adjust left and
ow)
Vertical blade
r
ight air fl
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Outlet
Inlet grille
6
5
2
1
4
3
6
4
2
1
5
3
(inside)
7
8
Anion generator
2 3
5
6
4
HEAT display
Display board
1
4
2
3
1
5
Operation mode indicator
(lights up when the compressor is on.)
Timer mode indicator
(Lights up whenTimer operation is selected.)
Power indicator
(Lights up when unit starts.)
Ambient temp display
When receiving the remote control signal, display the set temperature.
Remote signal receiver
(A beeping sound is generated when a signal from remote controller isreceived.)
1
2
3
4
5
2
Operation
Unit start / stop
1
3
2
2
Press FAN button.
Remote controller:
Press
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
3.Fan function
2.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
/
Remote controller
changes as follows:
LOW
MED HI
AUTO
Display circulated
Air Flow Direction Adjustment
1.Status display of air flow
When restart after remote turning off, the remote
return to the previous
2.Left and right air flow adjustment
Cautions:
When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
at air outlet if all vertical louvers are right.
mode ,
controller will automatically
Note:
set swing position.
Press button to enter additional options, when cycle display to , will flash. And then press
enter to Left and right air flow function.
(This function is unavailable on some models.)
COOL/DRY:
HEAT:
Initial state
Press button to enter additional options, when cycle display to , will flash. And then press
enter to up and down air flow function.
Press button. For each press,changes as follows:
Remote controller:
Press button. For each press,changes as follows:
Remote controller:
COOL/DRY/HEAT:
For each press button fan speed
In HEAT mode,warm air will blow out after a short periodof the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Cooling only unit do not have displays and functions related with heating
Display Board
Remote Controller
Note
COOL
DRY
HEAT
FAN
nothing
In DRY mode, when room temperature becomes lower than temp.setting+2
o
C,unit will run intermittently
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner
automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.
Operation Mode
AUTO
nothing
Remote controller A:
Remote controller B:
Press button to enter additional options, when cycle display to , will flash. And then press
enter to FAN function.
Loading of the battery
1
2
3
4
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with the
" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
Loading...