Haier HSU-12HVD03/R2, HSU-09HVD03-R2 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HVd03/R2(SDB) HSU-12HVd03/R2(SDB)
Contents
CAUTIONS
MAINTENANCE
TROUBLE SHOOTING
1 2
3 6 7
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010515053
Parts and Functions
Indoor Unit
Inlet
Inlet grille
Air purifying Filter(inside)
Anion generator
(inside)
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Display board
Vertical blade
(adjust left and
right air flow)
Please be subject to the actual produce purchased the above picture is just from your reference
Display board
Singal receiver hole
AUTO display
COOL display
Dry display
Ambient temp.display
When receiving the remote control signal,
display the set temperature and in the rest
time the room temperature is displayed and
this room temperature is only for reference.
TIMER OFF display
TIMER ON display SLEEP display
HEAT display
HEALTH display
(If the unit which you purchased
has healthy function,follow it.
If not,please ignore.)
FRESH AIR display
Outdoor Unit
Outlet
Remote controller
19
10. ON/OFF button
11. TIMER ON display
12
. FAN SPEED display
LOW HI
MED AUTO
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
17.FRESH AIR display
18. Operation mode display
28
FRESH
STERILIZE
1.CODE
Used to select CODE A or B with a press, A or B will be displayed on LCD. Please select A without special explanation.
2.RESET
When the remote controller appears abnormal, use a sharp pointed article to
press this button to reset the remote controller normal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
4. TIMER button
5. CLOCK button
6. SLEEP button
7. MODE button
8. HOUR button
9. HEALTH button
NOTE : The following functions andrelated displays are not available: 1
Operation m ode AU T O H E A T F A NCOOL DRY
Remotecontroller
Display board
19.Singal sending display
20.UV light degerming function display
33
21. Left/right air flow display
22. TEMP display
23. TIMER OFF display
24. TIMER/SLEEP display
25. TEMP button
26. FAN button
27. HEALTH AIRFLOW button
28. SWING UP/DOWN button
29. SWING LEFT/RIGHT button FRESH
30.
31. SET button
32. STERILIZE button
33. LOCK
34.Ambient temp.display
button
Used to lock buttons and LCD display.If pressed,the other buttons will be disabled and the lock condition display appears. Press it once again,lock will be canceled and lock condition display disappears.
When receiving the remote control signal, display the set temperatrue and in the rest time the room temperature is displayed and this room temperature is only for reference.
Loading of the battery
OUTLET
CONNECTING PIPING
AND ELECTRICAL WIRING
DRAIN HOSE
INLET
Please be subject to the actual produce purchased the above picture is just from your reference
Clock set
Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
After time setting is confirmed,press SET,
button is kept pressed,time will
"AM "and "PM" stop flashing,while clock starts working.
2
will increase
STERILIZE
Remove the battery cover;
1
Load the batteries as illustrated.
2
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-sta rted type fluorescent lamp or change- over
type fluorescent lamp or room, the recei so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
ver is apt to be disturbed in receiving
3
is in line with the
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
after taking-out, just need to press reset key.
" + "/"-";
the signals,
Operation
Base Operation
Remote controller
)5(6+
32:(562)7
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
3.Select temp.setting
Press button
Every time the button is pressed, temp.setting increase 1 rapidly
Every time the button is pressed, temp.setting decrease 1 decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as Remote controller:
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation
Mode
AUTO
COOL
DRY
HEAT
FAN
follows:
Remote
Controller
o
C,if kept depressed, it will increase
o
C,if kept depressed, it will
LOW
MED
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation
according to room temperature. to AUTO, the air conditioner
the fan speed according to room
In DRY mode , when room temperature becomes lower than temp.setting+2
intermittently at LOW speed regardless of FAN
setting.
In FAN operation mode , the unit will not operate in COOL or AUTO is not available in setting is disabled. In FAN mode, sleep operation
is not available.
HI
Note
HEAT mode but only in
FAN mode.
AUTO
When FAN is set
automatically adjusts
temperature.
o
C, unit will run
FAN mode ,
And temp.
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost.
When the emergency ope pressed,the" Pi "sound is heard once means
the start of this operation.
In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
Tem p e ra t ur e
ABOVE 23
BELOW 23
It is not possible to operate in dry mode.
Operation
O
C
COOLING
O
C
HEATING
mode
ration switch is
Designated temperature
26
23
O
C
O
C
, which
Ti me r mode
NO
NO
Air flow
AUTOMATIC
AUTOMATIC
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16 normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
After 3 0 minutes, test operation ends automatically.
o
C, do not use it in the
release
Air Flow Direction Adjustm
1.Status display of air sending
Vertical flap
Pos.1
Pos.4
2.Left and right air flow adjustment
For each press of button, remote controller displays as follows :
remote controller:
Pos. 1
Pos. 5
Cautions:
It is advisable not to keep vertical flap at
for a long time in COOL
condensate
When humidity is high, condensate water
air outlet if all horizontal
Unit won't restart until 3 minutes have
system protection.
cooling only unit.
Pos.2
Pos.5
Pos. 2
Pos. 6
Pos.3
Pos.6
Pos. 3
Pos. 7
or DRY mode, otherwise,
water might occur.
louvers are adjusted to left or right.
HEAT mode is not available on
(Auto swing)
(manual)
Pos. 4
Pos. 8
downward position
might occur at
elapsed, due to
3