Please read this operation manual before using the air conditioner.
No.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that
goes out of use, please make sure it's
inoperative and safe. Unplug the air
conditioner in order to avoid the risk of
entrapment.
It must be noticed that air conditioner
system contains refrigerants, which require
specialized waste disposal. The valuable
materials contained in an air conditioner
be recycled. Contact your local waste
disposal center for proper disposal of an
old air conditioner and contact your local
authority or your dealer if you have any
question. Please ensure that the pipework
of your air conditioner does not get
prior to being picked up by the relevant
waste disposal center, and contribute to
environmental awareness by insisting on
an appropriate, anti-pollution method of
disposal.
child
can
damaged
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide
carefully. The User's Guide contains very
important observations relating to the
assembly , operation and maintenance of
the air conditioner.
The manufacturer does not accept
responsibility for any damages that may
arise due to non-observation of the following
instruction.
Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
Disposal of the packaging of your
new air conditioner
All the packaging materials employed in
package of your new air conditioner may
disposed without any danger to the
environment.
The cardboard box may be broken or cut
smaller pieces and given to a waste paper
disposal service. The wrapping bag made of
polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken
to a waste collecting center and used again
after adequate recycling.
Consult your local authorities for the name
and address of the waste materials
collecting centers and waste paper disposal
services nearest to your house.
the
be
into
For the purpose of the safety,the air conditioner
must be properly grounded in accordance
with specifications.
Always remember to unplug the air
conditioner before openning inlet grill. Never
unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the outlet.
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.
Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or performating the air conditioner's tubes
with sharp or pointed items , crushing or
twisting any tubes , or scraping the coatings
off the surfaces. If the refrigerant spurts
out and gets into eyes , it may result in
serious eye injuries.
1
Cautions
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
7. The appliance is not intended for use by
young children or infirm persons without
supervision.
8. Young children should be supervised to
ensure that they do not play with the
applience.
9.Please employ the proper power plug,
which fit into the power supply cord.
10.The power plug and connecting cable
must have acquired the local attestation.
11.If the fuse of outdoor unit on PC board
is broken, please change them with the
corresponding type of T.1.0A/250V,
T.3.15A/250V,T.25A/250V.
2. If the power supply cord is damaged, it
must be replaced by the manufacturer
or its service agent or a similar qualified
person.
3. If the fuse of indoor unit on PC board is
broken,please change it with the type of
T. 3.15A/ 250V.
4. The wiring method should be in line with
the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
2
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to
the seriousness of possible risks and damages as follows. Compliance to the
instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth
cable.
earthing
Do not install in the
place where there is
any possibility of
inflammable gas
leakage around the
unit.
PROHIBITIONPROHIBITION
Do not get the unit
exposed to vapor
or oil steam.
3
Check proper
installation of the
drainage securely
STRICT
ENFORCEMENT
Cautions
When abnormality such as burnt-small found,
immediately stop the operation button and
contact sales shop.
WARNING
Use an exclusive power source with a
circuit breaker
OFF
Connect power supply cord
to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord
in a bundle.
PROHIBITION
Do not start or stop the
operation by disconnecting
the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly
at people, especially at infants or
the aged.
PROHIBITION
CAUTION
Take fresh air occasionally especially
when gas appliance is running at the
same time.
Do not use power supply cord
extended or connected in halfway
PROHIBITION
Do not insert objects into the air
inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct
by yourself.
Do not operate the switch with
wet hand.
PROHIBITION
Do not install the unit near a fireplace
or other heating apparatus.
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the
installation stand
PROHIBITION
Do not place any objects on or
climb on the unit.
PROHIBITION
4
PROHIBITION
Do not pour water onto the unit
for cleaning
PROHIBITION
Do not place flower vase or water
containers on the top of the unit.
PROHIBITION
Parts and Functions
Indoor unit
Signal receiving window
Inlet grille
Air Purifying Filterr
(inside)
Vertical louver
(Use remote controller to
adjust up and down air flow.
Donít adjust it manually)
Horizontal louver
(adjust left and right air flow)
Control panel
Operation indicator
Healthy operation indicator
Human sensing indicator
Light sensing receiver
Human sensor
Outlet
Air filter(inside)
Anion generator
(inside)
Power plug
Timed operation indicator
Sleep indicator
Power indicator
Remote signal receiver
Outdoor unit
Connecting piping and
electrical wiring
Inlet
Outlet
Drain hose
5
Parts and Functions
18
17
16
15
14
13
12
11
11
10
9
8
7
6
5
4
3
2
36
1
button(light sensing)
1.
It is to set light sensing function,
which enables normal operation
for strong indoor light (day) or
sleeprunning mode for weak
indoor light (night).
2.RESET
When the remote controller appears
abnormal, use a sharp pointed article
to press this button to reset the
remote controller normal.
button
3.
It is to set human sensing function,
which automatically gets standby if
detecting no human activity for
continuously 20 min, and automatically
starts running upon re-detecting
human activity.
4.TIMER button
Used to select TIMER ON,
TIMER OFF,TIMER ON-OFF
5. CLOCK button
Used to set correct time.
6. SLEEP button
Used to select sleep mode.
7.MODEbutton
19
20
21
22
23
24
25
26
27
35
28
29
30
31
32
33
AUTOCOOLDRYFANHEAT
8.HOUR button
Used to set clock and timer setting
9.HEALTHYbutton
Used to set healthy operation.
10. ON/OFF button
Used for unit start and stop.
11. TIMER ON display
12. FAN SPEED diaplay
LOW
MED
HI
13. LOCK diaplay
14. SWING UP/DOWN diaplay
15. SLEEP diaplay
16. HEALTH diaplay
diaplay
17.
diaplay
18.
diaplay
19.
20.SIGNAL SENDING diaplay
AUTO
21.POWER/SOFT diaplay
22.Left/right air flow display
34
23.TEMP display
Remote controller: to display the TEMP. setting
24. TIMER OFF display
25. CLOCK display
26.TEMP button
Used to select your desired temperature.
27.FAN button
Used to select fan speed: LO,MED, HI, AUTO.
28.SWING UP/DOWN button
Used to select up or down air sending direction.
29.SWING LEFT/RIGHT button
Used to select left/right air flow.
30.SET button
Used to confirm timer and clock settings.
31.POWER/SOFT button
32. button
Used to select nature air
33.LOCK
Used to lock buttons and LCD display. If
pressed, the other buttons will be disabled and
the lock condition display appears.
Press it once again, lock will be canceled and
lock condition display disappears.
34. LIGHT display
Only for the model with background
lighting function.
35. HEALTH AIRFLOW button
Used to set the health airflow mode.
6
Parts and Functions
36. CODE
Used to select CODE A or B with a press,A or B will be displayed on LCD.
please select A without special explanation
NOTE:
The following functions and related displays are nto available:
CODE and LIGHT.
Clock Set
When unit is started for the first time and after replacing batteries in remote
controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease 1
min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing,
while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7 m without
any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless
telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the
distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right.
2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" " area and push down the cover
as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-" pole
request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up.
Please
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and
reload
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display afte
taking-out, just need to press reset key.
change batteries.
several minutes later.
r
7
Operation
HEALTH Operation
Remote Controller
1. Unit start
Press ON/OFF the remote controller, unit starts.
2. Select operation mode
Press HEALTH button. For each press, is displayed
now the air copnditioner is operating the healthy function.
3. Unit stop
Press HEALTH button, the health function stops.
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to
effectively balance the quantity of position and anion in the air and also to kill
bacteria and speed up the dust sediment in the room and finally clean the air
in the room.
Note
When the fan in the indoor unit does not work, the health lamp lights up, but
the anion generator does not release anion.
8
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.