OPERATION MANUAL
HSU-12HQA03/R2(DB)
Please read this operation manual before using the air conditioner
0010538206
Contents
Parts and functions Operation Maintenance
Cautions Trouble shooting
2 3
6 7
8
1
Parts and Functions
Indoor Unit
Inlet
Inlet grille
Nano-Aquo Generator inside
Outlet
Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
Actual indoop unit may vary from the one shown
in the manual, according to the product purchased.
Display board
Aureole
Display modethe aureole display different colour when setting different function
COOL: blue
AUTO: white
HEAT: red
DRY: cyan
TEMP display
FAN: yellow
Nano-Aquo
Outdoor Unit
Air Purifying Filter
generator
(inside)
Vertical blade
(adjust left and
right air fl
: green
Anion
ow)
Remote controller
9. ON/OFF button
10. TIMER ON display
11. FAN SPEED display
19
LOW HI
MED AUTO
12. LOCK displ
13. SWING display
14. SLEEP display
15. HEALTH display
16. Operation mode display
Operation mode
28
Remote controller
17.Singal sending display
30
31
1
RESET button
.
When the remote controller
appears abnormal,use a sharp pointed article to press this button to reset the remote controller controller normal.
2.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
3. TIMER button
4. CLOCK button
5. SLEEP button
6. MODE button
7. HOUR button
8. HEALTH button
The following functions and related displays are not available
18. POWER/SOFT display
19. Left/right air flow display
20. TEMP display
21. TIMER OFF display
22. TIMER display
23. TEMP button
24. FAN SPEED button
25. HEALTH AIRFLOW button
26. SWING UP/DOWN button
27. SWING LEFT/RIGHT button
28. SET button
29. POWER/SOFT button
LOCK
.
30
If pressed, the other buttons will be disabled. Press it once again, lock will be cancelled.
31. CODE
Used to select CODE A or B with a press, A or B will be displayed on LCD. Please select A without special explanation.
AUTO
button
ay
COOL DRY
HEAT
Loading of the battery
FAN
31
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
"AM "and "PM" stop flashing,while clock starts working.
After time setting is confirmed,press SET,
button is kept pressed,time will
will increase
Remove the battery cover;
1
2
Load the batteries as illustrated.
2
2 R-03 batteries, resetting key
1
(cylinder);
Be sure that the loading
3
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or room, the recei so the distance to the indoor unit should be sho
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
2
ver is apt to be disturbed in receiving
3
is in line with th
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
after taking-out, just need to press reset key.
e" + "/"-";
the signals,
rter.
Operation
Base Operation
Remote controller
1
2
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
3.Select temp.setting
Press button
Every time the button is pressed, temp.setting increase 1 rapidly
Every time the button is pressed, temp.setting decrease 1 decrease rapidly
Select a desired temperature.
/
o
C,if kept depressed, it will increase
o
C,if kept depressed, it will
4.Fan speed selection
Press FAN button. For each press, fan speed changes as Remote controller:
follows:
4
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once means
the start of this operation.
In this operation, the system automatically selects
operation modes
the according to the room temperature.
Room
temperature
O
ABOVE 24
BELOW 24
Room temperature
It is not possible to operate in dry mode.
C
O
C
ooling only uint
(C
BELOW 2
,cooling or fan or heat,
.
Operation mode
COOLING
HEAT
O
4
C
Designated temperature
Operation
mode
2
2
FAN
O
4
C
O
C
4
Designated temperature
, which
Timer
mode
NO
NO
O
C
2
4
AUTOMATIC
Air flow
AUTOMATIC
Timer mode
NO
emergency operation switch
Air flow
AUTOMATIC
Pi
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16 normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
o
C, do not use it in the
release
test operation
switch
Pi
Pi
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1
Pos.2
Pos.3
LOW
MED
HI
AUTO
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation
Mode
AUTO
COOL
DRY
FAN
HEAT
Remote
Controller
Note
Under the mode of auto operation, air conditioner
will automatically select Cool or Heat operation according to room temperature. When FAN is set to AUTO, the air conditioner the fan speed according to room
In DRY mode, when room temperature becomes
lower than temp.setting+2 intermittently at LOW speed regardless of FAN setting.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in
AUTO is not available in setting is disabled. In FAN mode, sleep operation
is not available.
automatically adjusts
temperature.
o
C, unit will run
FAN mode ,
FAN mode.
And temp.
Pos.4
Pos.5
Pos.6
(Auto swing)
2.Left and right air flow adjustment
For each press of button, remote controller displays as follows :
remote controller:
Pos.1
Pos.5
Pos.2
Pos.6
Pos.3
Pos.7
Pos.4
Pos.8
Cautions:
When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur at air outlet if all vertical louvers are
right. It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote
controller will automatically
memorize the previous
set swing position.
3
adjusted to left or
mode ,
Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
O
1 higher than temp.setting.After another 1 hours,
C
temp.rises by 1 futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.
SLEEP operation starts SLEEP operation stops
1 hr
O
1 hr
C
Rises 1
Approx.6hrs
Rises 1OC
O
C
In AUTO mode
3.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
Note
When TIMER function is set, the sleeping function can't be set up .After the sleeping function is set up
,
if user resets TIMER function, the sleeping function will be cancelled;the machine will be in the state of timing-on.
POWER/SOFT Operation
(1)
POWER Operation
When you need rapid heating or cooling, you can use this function.
high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode.
(2)
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed
automatically takes low speed of AUTO fan mode.
In COOL mode, fan speed automatically takes
SOFT Operation
Temp.setting
Unit stop
In COOL, DRY mode
In HEAT mode
2.
1 hours after SLEEP mode starts,temp will become 2 lower than temp.setting.After another 1 hours,temp decrease by 2
O
C
O
C
futher.After more another 3hours,temp.rises
O
C
by 1 futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
Temp.setting
1 hr
1 hr
SLEEP operation starts
Decreases 2OC
Decreases 2
3 hrs
Unit stop
O
C
3 hrs
Rises 1OC
SLEEP operation stops
In HEAT mode
Note
During POWER operation, in rapid HEAT or COOL mode , the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again ,POWER or SOFT
disappear
s.
Nano-Aquo Operation
Nano-Aquo generator adopt high voltage two poles to ionization the water moleculeproduce plenty of positive and negative Ionsand realease these inos to the air to kill the bacterium.And meantimebecause the negative ions qty more than positive ions qtythe Nano-Aquo generator also have the Negative ions generator function which can refresh the air.
4
Operation
5
Timer On/Off On-Off Operation
Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press TIME+ /TIME- button to set time. It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing.
5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears.
Hints: After replacing batteries or a power failure happens, time
setting should be reset. Remote controller possesses memory function,when use
TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Healthy airflow Operation
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
1).Press the button of healthy airflow
display. Horizontal airflow sending.
blows direct to the body.
2).Press the button of healthy airflow again, appears on the displa blows direct to the body.
3.The cancel of the healthy airflow function Press the button of healthy airflow again, working under the condition before the setting of healthy
airflow function.
Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop
. Downward airflow sending.
y
for a minute and then start, adjusting by remote controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
2.In heating, it is better to select the
3.In cooling, it is better to select the
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may occur at the grille .
, appears on the
Avoid the airflow
Avoid the airflow
the unit
mode. mode.
goes on
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper
temperature
Close doors and windows during operation
During cooling operation
prevent the penetration of
direct sunlight with
curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
Indoor Body
wipe the air conditioner by using a soft and dry cloth.For serious stains,
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
damage the coating of the unit.
ay
m
Hot water over 40 cause
discoloring or deformation.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is
released
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication
is
completely
and left filters are not
may cause defects.
Close the inlet grille.
from the stopper, and remove the filter do
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
O
C(104OF) may
wnw
ard.
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of the indoor unit.
2.Detach the standard air filter
Slide the knob slightly up release the filter, then withdraw it.
3.Attach Air Purifying Filter
Put air purifying filter appliances into the
right and left filter frames.
ward to
Detach old Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
ATTENTION:
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit.
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will reduced.
it will be solarized every 6 months.
avoid long time directly sunshine
be
6
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker
Check proper installation of the drainage securely
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
ENFORCEMENT
Use the proper voltage
Take care not to damage
the power supply cord.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
Do not channel the air flow directly at people, especially at infants or the aged.
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
STRICT ENFORCEMENT
1.Do not use power supply cord extended or connected in halfway
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not operate the switch with wet hand.
Connect the earth cable.
earthing
PROHIBITION
Do not install the unit near a fireplace
or other heating apparatus.
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
7
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
Trouble shooting
8
Cautions
Before asking for service, check the following first.
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after
unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation,
indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
In DRY mode, when room temperature becomes lower than temp. setting+2
intermittently at LOW speed
regardless of FAN setting. Is power plug inserted?
Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or
windows left open? Is there any direct sunlight through the window during the
cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?
o
C,unit will run
Normal Performance inspection
Multiple
check
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
In dry mode, speed can’t be changed.
Poor cooling
fan
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
Do not allow children to play with the air
case should children be
swing louver.
or any other things into the
allowed to sit on the outdoor unit.
grille of the air
conditioner
Specifications
The refrigerating circuit is leak-proo f.
The machine is adaptive in following
1.Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Outdoor
(INVERTER)
2. If the power supply cord is damaged, it manufacturer
3. If the fuse of indoor unit on PC board is
it with the type of
broken,change it with the type of
4. The wiring method should be in line with
5. After installation, the power plug should
6. The waste battery should be disposed
7. The appliance is not intended for use
persons
8.Young children should be supervised
the appliance.
with
9. Please employ the proper power plug, cord.
10. A breaker should be incorporated into
should be
contacts should be not less than
11 .The power plug and connecting cable
attestation.
12.In order to protect the units,please turn
30 seconds
13.Please don't insert any sensor on 3-way
or its service agent or a similar
without supervision.
all-pole switch and the distance
later, cutting off the power.
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:
Maximum:D.B Minimum:
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B
T. 3.15A/ 250V
D.B
D.B
must be replaced
broken,please
. If the fuse of
T.25A/250V
the local wiring
be easily reached.
properly.
by young children or
to ensure that th
which fit into the
fixed wiring. The
between
3mm.
must have
off the A/C first,
stop valve pipe
situation
32oC/23oC
o
21
C/15oC
o
43
C/26oC
o
18
C
o
C
27 0oC
o
C/18oC
24
o
-
C/-8oC
7
o
C/18oC
24
o
C
-15
qualified
outdoor
its two
acquired the local
.In no
by the
person.
change
unit is
standard.
infirm
ey
do not play
p
ower supply
breaker
and at least
fitting.
Specifications
9
AIR-CONDITIONING
MODEL
12 Months Gurantee
Norminal cooling Capacity Hp
Power(W)
RATED CURRENT(A)
BTU
VOLTAGE@50Hz(Nominal)
Refrigerant
Net Weight kg
Dimensions(Ht x Wx D) indoor
Dimensions(Ht x Wx D) outdoor
Speed Fan-VARIABLE SPEED
Adjustable Thermostat
"Auto swing" Air Direction
HSU-12HQA03/R2(DB)
YES
1
990
4.6
12000
220
R410A 1.01kg
indoor 10.8 /outdoor 34
860 x 175 x 285
780 x 270 x 540
YES
YES
YES
Easy Clean Filter
Remote Control F acility
Builtt o withstand Voltage F lunctuations
Anti Electric Shock
Tropicalised
Electrostatics F ilter
eria killing UV ray
Bact
Note: All capacities are gross.
HAIER-THERMOCOOL reserves the right to change specifications as part of its policy of continuous improvement.
YES
YES
YES
CLASS I
YES
NO
NO
Electrical Diagram
10
12k wiring diagram of split unit indoor

INDOOR FAN MOTOR
WATER ION GENERATOR
TO BILATERAL FRESH AIR MOTOR
ASSISTANT ELECTRIC HEATING


󰷅 R
󰷅 W
󰷅 BL
HP1󰷅 B
HP2󰷅 W

FUSE














LEFT STEP MOTOR
RIGHT STEP MOTOR
LEFT PANEL MOTOR
RIGHT PANEL MOTOR
UP-DOWN STEP MOTOR
DISPLAY BOARD
EMERGENCY SWITCH
WIRELESS NET MODULE
NET APPLIANCE MODULE
AMBIENT TEMP.SENSOR
PIPING TEMP.SENSOR
NOTES:THE DOTTED PARTS ARE OPTIONAL.
󰷅󰷅
1(N)
2(L)
3(C)
󰷅
Power


󰷅
1PH,220V~,50Hz
NOTES
B BLACK R RED
BR BROWN
BL BLUE W WHITE
Y/G YELLOW/GREEN
Electrical Diagram
11
12k wiring diagram of split unit indoor
to double-way air
exchange motor
TO INDOOR UNIT
B:BLACK
R:RED BL:BLUE
PFC REACTOR
1 2 3
GND
to single-way
air exchange motor
W:WHITE
Y/G:YELLOW/GREEN
OR:ORANGE
W B
R
Y/G
CN6
CN9
CN7
Y/G
GND
BL
CN3
AC-L
CN9
CN15
PE
W
CN14
AC FAN MOTOR
AC-N
CN8
1A/250VAC
FUSE2
CN11
Electric Heating Cable
CN1
CN2
CN4
CN10
BL
4-WAY VALVE
Remark:the dotted parts are
optional for different unit.
MODULE BOARD
CN8
AC-N
AC-L
CN10
CN11
CN5
B
CN22
CN23
MAIN CONTROL BOARD
CN13
CN16
ELECTRIC
EXPANSION VALVE
R
W
CN4
BL
CN20
TEMP.SENSOR
AMBIENT
W
V
CN3
CN19
TEMP.SENSOR
DEFROST
B
U
CN2
OR
CN26
CN24
CN21
CN18
CN1
CN17
TEMP.SENSOR
SUCTION
TEMP.SENSOR
COMPRESSOR DISCHARGE
WARNING
CAUTION
DON'T TOUCH CAPACITOR, EVEN AFTER PLUG-OFF ( DANGER OF ELECTRIC SHOCK)
The capacitor retains high voltage even after the plug-off. For your safety, be sure to wait at least 5 minutes. after plug off and use a tester to confirm the voltage between connector P and N(on module board) is less than DC 10V before start servicing.
Outdoor EEPROM error
DC FAN MOTOR
The protection of IPM Overcurrent protection
of AC electricity
Communication fault
between the IPM and CBD
Over pressure or Overheat protection for the compressor
Power voltage is too high or low
Overheat protection for exhaust temperature
Frost-removing temperature sensor failure
Ambient temperature sensor failure
Exhaust temperature sensor failure Deviate from the normal
for the compressor Loop of the station detect error Overcurrent of the compressor
Overcurrent protection for single-phase of the compressor
Description
LED1 Flash
Times
1 2
3
4
5
6
8
10
12 13
18
19
24
25