Haier HSU-12HM03, HSU-12HM03(B) Operation Manual

OPERATION MANUAL
No.0010544529
Please read this operation manual before using the air conditioner.
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items , crushing or twisting any tubes , or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes , it may result in serious eye injuries.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of
child
entrapment. It must be noticed that air conditioner
system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner
can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get
damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in
the
package of your new air conditioner may
be disposed without any danger to the environment.
The cardboard box may be broken or cut
into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
Cautions
The machine is adaptive in following situation
Cooling
Heating
Indoor
Indoor
Outdoor
Outdoor
Maximum: D.B/W.B 32°C / 23°C Minimum: D.B/W.B 18°C / 14°C
Maximum: D.B/W.B 43°C / 26°C
Minimum: D.B 18°C Maximum: D.B 27°C
Minimum: D.B 15°C Maximum: D.B/W.B 24°C / 18°C
Minimum: D.B/W.B -7°C / -8°C
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken, change it with the type of F.20A/250V.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
10.Please employ the proper power plug, which fit into the power supply cord.
11.The power plug and connecting cable must have acquired the local attestation.
Cautions
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
CAUTION
Installation in a inadequate place may cause accidents. Do not install in the following place.
Connect the earth cable.
PROHIBITION PROHIBITION
STRICT
ENFORCEMENT
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Safety Instruction
Cautions
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Connect power supply cord to the outlet completely.
Use the voltage AC220~230V.
Take care not to damage the power supply cord.
Do not use power supply cord in a bundle.
Do not use power supply cord extended or connected in halfway.
Do not insert objects into the air inlet or outlet.
Do not try to repair or reconstruct by yourself.
Do not channel the air flow directly at people, especially at infants or the aged.
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
OFF
STRICT ENFORCEMENT
STRICT ENFORCEMENT
Use an exclusive power source with a circuit breaker.
CAUTION
Do not use for the purpose of storage of food, art work, precise equipment, breeding , or cultivation.
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not operate the switch with wet hand.
Do not pour water onto the unit for cleaning.
Check good condition of the installation stand.
Do not install the unit near a fireplace or other heating apparatus.
Do not place animals or plants in the direct path of the air flow.
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
PROHIBITIONPROHIBITION
PROHIBITIONPROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
STRICT ENFORCEMENT
WARNING
STRICT ENFORCEMENT
RES
TI
MO SW
FA
PO
ON
TE
Cautions
Parts and Functions
Indoor unit
Inlet grille
Outlet
Signal receiving window
Horizontal louver
(Use remote controller to adjust up and down air flow. Don’t adjust it manually)
(adjust left and right air flow)
Vertical louver
Air filter
Power plug
Anion generator (inside)
Outdoor unit
Human sensor
Timed operation indicator
Operation indicator
Light sensing receiver
Human sensing indicator
Healthy operation indicator
Remote signal receiver
Power indicator
Sleep indicator
TIMER RUN
HUMAN SENSE
SLEEP
POWER
HEALTH
Control panel
Multi photic catalyst air filter (inside)
Parts and Functions
Remote Controller
8.HOUR button Used to set clock and timer setting
9.HEALTHY button
Used to set healthy operation.
10. ON/OFF button Used for unit start and stop.
24. TIMER OFF display
13. LOCK diaplay
14. SWING UP/DOWN diaplay
15. SLEEP diaplay
16. HEALTHY diaplay
18. diaplay
20.SIGNAL SENDING diaplay
21.POWER/SOFT diaplay
22.Left/right air flow display
19. diaplay
23.TEMP display Remote controller: to display the TEMP. setting
25. CLOCK display
26.TEMP button Used to select your desired temperature
27.FAN button Used to select fan speed: LO,MED, HI, AUTO
28.SWING UP/DOWN button Used to select up or down air sending direction.
29.SWING LEFT/RIGHT button Used to select left/right air flow.
30.SET button Used to confirm timer and clock settings.
31.POWER/SOFT button
33.LOCK Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
6.SLEEP button
Used to select sleep mode.
7.MODE button
AUTO COOL DRY FAN HEAT
34. LIGHT display It is to set light sensing function, which enables normal operation for strong indoor light (day) or sleep running mode for weak indoor light (night).
12. FAN SPEED diaplay
AUTO
HI
MED
LOW
32. button
Used to select nature air
17. diaplay
MODE
CLOCK
POWER/SOFT
TIMER
SET
LOCK
TEMP
HEALTH FAN
OFF
ON
1
23
27
4 3
2
25
22
7
5
6
12
15
8
13
14
26
10
11
9
20
24
28
29
30
31 32
34
21
17
18
19
RESET
LIGHT
SLEEP
SWING
16
33
2.RESET When the remote controller appears
abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
4.TIMER button Used to select TIMER ON, TIMER OFF,TIMER ON-OFF
5.CLOCK button
Used to set correct time.
1. button (light sensing)
It is to set light sensing function,
which enables normal operation for strong indoor light (day) or sleep running mode for weak indoor light (night).
3. button It is to set human sensing function,
which automatically gets standby if detecting no human activity for continuously 20 min, and automatically starts running upon re-detecting human activity.
Parts and Functions
Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7 m without any obstacle as well. Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless
telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery Load the batteries as illustrated right.
2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" " area and push down the cover as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-" pole request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please
change batteries. Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and reload
several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display afte
r
taking-out, just need to press reset key.
1.DO NOT MIX OLD WITH NEW BATTERIES AND DO NOT USE BATTERIES OF DIFFERENT TYPES TOGETHER
2.INSERT CORRECTLY 2 (TWO) R-03 BATTERIES IN THE + - POLARITY
3.PLEASE REMOVE THE BATTERIES WHEN THE REMOTE CONTRLLER DISORDER,AND RELOAD NEW'S AFTER SIX MINUTES
REMOTE CONTROL UNIT
MODEL:YR-H05
1.DO NOT MIX OLD WITH NEW BATTERIES AND DO NOT USE BATTERIES OF DIFFERENT TYPES
TOGETHER
2.INSERT CORRECTLY 2 (TWO) R-03 BATTERIES IN THE + - POLARITY
3.PLEASE REMOVE THE BATTERIES WHEN THE
REMOTE CONTRLLER DISORDER,AND RELOAD
NEW'S AFTER SIX MINUTES
REMOTE CONTROL UNIT
MODEL:YR-H05
-
+
-
+
1.DO NOT MIX OLD WITH NEW BATTERIES AND DO NOT USE BATTERIES OF DIFFERENT TYPES TOGETHER
2.INSERT CORRECTLY 2 (TWO) R-03 BATTERIES IN THE + - POLARITY
3.PLEASE REMOVE THE BATTERIES WHEN THE REMOTE CONTRLLER DISORDER,AND RELOAD NEW'S AFTER SIX MINUTES
REMOTE CONTROL UNIT
MODEL:YR-H05
-
+
-
+
CLOCK
POWER/SOFT
TIMER
SET
LOCK
RESET
LIGHT
MODE
SLEEP
SWING
Operation
HEALTH Operation
1. Unit start
Press ON/OFF on the indoor unit,or press ON/OFF on the remote controller, unit starts. Previous operation status appears on LCD display , and set the operation mode.
2. Select operation mode
Press HEALTH button. For each press, is displayed now the air copnditioner is operating the healthy function.
3. Unit stop
Press HEALTH button, the healthy function stops.
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
Note
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
Remote Controller
MODE
CLOCK
POWER/SOFT
TIMER
SET
LOCK
TEMP
HEALTH FAN
OFF
ON
RESET
LIGHT
SLEEP
SWING
2
1
3
Operation
AUTO Operation
1. Unit start
Press ON/OFF on the indoor unit,or press ON/OFF on the remote controller, unit starts. Previous operation status appears on LCD display , and set the operation mode.
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Then Select AUTO operation
3. Unit stop
Press ON/OFF button, the unit stops.
About AUTO mode In AUTO run mode, the air conditioner will automatically select cooling or heating operation mode according to room temperature.
AUTO
COOL DRY FAN
HEAT
Remote Controller
MODE
CLOCK
POWER/SOFT
TIMER
SET
LOCK
TEMP
HEALTH FAN
OFF
ON
RESET
LIGHT
SLEEP
SWING
2
1
3
Operation
COOL Operation
1. Unit start
Press ON/OFF on the indoor unit,or press ON/OFF on the remote controller, unit starts. Previous operation status appears on LCD display.
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
Then Select COOL operation.
3. Select temp. setting Press TEMP. button. Every time the button is pressed, temp. setting increases 1°C , if kept depressed, it will increase rapidly. Every time the button is pressed, temp. setting decreases 1°C , if kept depressed, it will decrease rapidly.
Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
AUTO COOL DRY FAN HEAT
Remote Controller
AUTO
HI
MED
LOW
MODE
CLOCK
POWER/SOFT
TIMER
SET
LOCK
TEMP
HEALTH FAN
OFF
ON
RESET
LIGHT
SLEEP
SWING
3
3
2
1
5
4
Operation
DRY Operation
COOL operation starts when room temp. is higher than temp. setting.
Ultra-low air flow
Temp. setting+2 C
Temp. setting
On reaching temp. setting +2°C, unit will run in mild DRY mode.
Remote Controller
MODE
CLOCK
POWER/SOFT
TIMER
SET
LOCK
TEMP
FAN
OFF
ON
RESET
LIGHT
SLEEP
SWING
HEALTH
1
2
3
3
4
5
1. Unit start
Press ON/OFF button on the indoor unit or press ON/OFF on the remote controller, unit starts. Previous operation status appears on LCD display .
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
Conrol panel: Then Select DRY operation.
3. Select temp. setting Press TEMP. button. Every time the button is pressed, temp. setting increases 1°C , if kept depressed, it will increase rapidly. Every time the button is pressed, temp. setting decreases 1°C , if kept depressed, it will decrease rapidly. Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
In DRY mode, when room temperature becomes 2°C higher than temp. setting, unit will intermittently at LO speed regardless of FAN setting.
5. Unit stop
Press ON/OFF button, the unit stops.
AUTO
HI
MED
LOW
AUTO COOL DRY FAN HEAT
Loading...
+ 26 hidden pages