Haier HSU-12HEA103/R2, HSU-09HEA103/R2 User Manual

SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
HSU-07HEA03/R2
Contents
CAUTIONS PARTS AND FUNCTIONS
OPERATION MAINTENANCE
TROUBLE SHOOTING
Índice
PRECAUCIONES
COMPONENTES Y FUNCIONES
FUNCIONAMIENTO
MANTENIMIENTO
RESOLUCIÓN DE PROBLEMAS
....................................................
....................................................
......................................................................
..........................................................
....................................................
................................................................
......................................................................
1 2 3 6
7
1
....................................................................
..........................................................
9 10 13 14
HSU-09HEA03/R2 HSU-12HEA03/R2 HSU-18HEA03/R2
HSU-22HEA03/R2
Contenuti
AVVERTENZE PARTI E FUNZIONI FUNZIONAMENTO
MANUTENZIONE RISOLUZIONE DEI PROBLEMI
HSU-24HEA03/R2 HSU-09HEA103/R2
HSU-12HEA103/R2 H2SM-(9+9)HEA03/R2
H2SM-(9+12)HEA03/R2
Pleasereadthisoperationmanualbeforeusingtheairconditioner.
Keep this operation manual for future reference.
Table des matières
AVERTISSEMENTS PIÈCES ET FONCTIONS
OPÉRATION MAINTENANCE DÉPANNAGE
....................................................
....................................................................
................................................................
......................................................................
..........................................................
....................................................
....................................................................
................................................................
......................................................................
..........................................................
1
16
17
20
21
1
23 24 27 28
0010526880
Parts and Functions
Indoor Unit
Inlet grille
Inlet
Outlet
Anion generator
(inside)
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Please be subject to the actual produce purchased the above picture is just from your reference
Display board
Singal receiver hole
COOL display
HEAT display
TEMP display
HEALTH display
(If the unit which you purchased
has healthy function,follow it.
If not,please ignore.)
 
Display board
Remote signal receiver
ALTH display
HE
TIMER OFF display
TIMER ON display SLEEP display
TEMP
display
Air Purifying Filter
Emergency
Switch
Vertical blade
(adjust left and
right air fl
ow)
Display board
Dry display
TIMER OFF display
TIMER ON display SLEEP display
 
AUTO display COOL display
Dry display
HEAT display
Outdoor Unit
4
OUTLET
INLET
Please be subject to the actual produce purchased the above picture is just from your reference
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote controller
CLOCK button
5.
6. HEALTH button
19
7. MODE button
8. HOUR button .
SWING
9
button
10. ON/OFF button
11.TIMER ON display
12.FAN SPEED display
LOW HI
MED AUTO
13. LOCK display
14. SWING display
POWER/SOFT
28
.
HEALTH display
16
.
SLEEP display
15
17. Operation mode display
AUTO
30
Operation mode
Remote controller
COOL DRY
FAN
HEAT
18.Singal sending display 19
. POWER/SOFT display . Left/right air flow display
1.CODE
Use to select CODE A or B which will be displayed on LCD.Please select A without special explanation.
RESET
2.
When the remote controller
appears abnormal,use a
sharp pointed article to
press this button to reset the
remote controller normal.
button
3.LIGHT button
Control the lightening and extinguishing of the indoor
LED display board.
4.TIMER
button
The following displays are not available:
20
21. TEMP display . TIMER OFF display
22
23. CLOCK display
. TEMP button
24
25. FAN button
26. HEALTH AIRFLOW button
27
. SLEEP button
28. SET button
29. POWER/SOFT button
30. LOCK button
If pressed, the other buttons will be disabled Press it once again,
lock will be cancelled.
20
The following functions and related displays are only
29
available for model HSU-22HEA03/R2ǃHSU-24HEA03/R2 :
19
Loading of the battery
Remove the battery cover;
1
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
type fluorescent lamp or room, the recei so the distance to the indoor unit should be shorter
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
ver is apt to be disturbed in receiving
Load the batteries as illustrated.
2
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
3
is in line with th
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
after taking-out, just need to press reset key.
e" + "/"-";
the signals,
2
Operation
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
After time setting is confirmed,press SET,
button is kept pressed,time will
will increase
"AM "and "PM" stop flashing,while clock starts working.
C
POWER/SOFT
Base Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
3.Select temp.setting
Press
Select a desired temperature.
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will decrease
rapidly
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation
Mode
AUTO
COOL
DRY
HEAT
FAN
Display Board
nothing
Remote
Controller
1
2
HI
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner according to room
In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
4
POWER/SOFT
AUTO
Note
When FAN is set to AUTO, the
automatically adjusts the fan speed
temperature.
o
C,unit will run intermittently
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost.
When the emergency ope
pressed,the" Pi "sound is heard once
means
the start of this operation.
In this ope
the according to the room temperature.
temperature
ABOVE 23
BELOW 23
Room temperature
It is not possible to operate in dry mode.
ration, the system automatically selects
operation modes
Room
(cooling only uint)
BELOW 23
O
C
O
C
Operation mode
COOLING
HEAT
O
C
ration switch is
,cooling or fan or heat,
.
Designated temperature
26
Operation
mode
FAN
O
C
O
C
23
, which
Timer
mode
NO
NO
Designated temperature
O
26
C
AUTOMATIC
AUTOMATIC
Timer mode
Air flow
NO
Pi
Air flow
AUTOMATIC
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16 normal operation.
o
C, do not use it in the
Pi Pi
Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice,
release
your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1
Pos.4
2.Left and right air flow adjustment
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are
right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note: When restart after remote turning off, the remote
controller will automatically
set swing position.
Pos.2
Pos.5
Pos.3
Pos.6
(Auto swing)
(manual)
conditioner
adjusted to left or
mode ,
memorize the previous
3
Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
O
1 higher than temp.setting.After another 1 hours,
C
temp.rises by 1 futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.
SLEEP operation starts SLEEP operation stops
Temp.setting
In HEAT mode
2.
1 hours after SLEEP mode starts,temp will become 2 lower than temp.setting.After another 1 hours,temp decrease by 2 futher.After more another 3hours,temp.rises
O
C
by 1 futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
O
C
Approx.6hrs
Rises 1
Rises 1OC
O
C
1 hr
1 hr
In COOL, DRY mode
O
C
Unit stop
O
C
In AUTO mode
3.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
Note
When TIMER function is set, the sleeping function can't be set up .After the sleeping function is set up
,
if user resets TIMER function, the sleeping function will be cancelled;the machine will be in the state of timing-on.
POWER/SOFT Operation
(1)
POWER Operation
When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed antomatically takes high speed of AUTO fan mode.
(2)
SOFT Operation
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed antomatically takes low speed of AUTO fan mode.
Note˖
During POWER operation, in rapid HEAT or COOL mode, the room will show inhomogeneous temperature distribution. During SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation The POWER / SOFT symbols on the remote controll will be disappeared after 15 minutes, the unit continues to run according to the original state. Press POWER/SOFT button again, POWER or SOFT disappears.
HEALTHY Operation
Temp.setting
1 hr
1 hr
SLEEP operation starts
Decreases 2OC
Decreases 2
3 hrs
In HEAT mode
Unit stop
O
C
3 hrs
Rises 1OC
SLEEP operation stops
Healthy Negative ions
The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
4
Operation
Timer On/Off On-Off Operation
Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press / button to set time. It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing.
5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function,when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Healthy airflow Operation
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
1).Press the button of healthy airflow
display. Horizontal airflow sending.
blows direct to the body.
2).Press the button of healthy airflow again, appears on the displa blows direct to the body.
3.The cancel of the healthy airflow function
Press the button of healthy airflow again,
working under the condition before the setting of healthy
airflow function.
Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop
. Downward airflow sending.
y
for a minute and then start, adjusting by remote controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
2.In heating, it is better to select the
3.In cooling, it is better to select the
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may occur at the grille .
, appears on the
Avoid the airflow
Avoid the airflow
the unit
mode. mode.
goes on
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
CE
All the products are in conformity with the following European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
WEEE
In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.This means that electrical and electronic
products shall not be mixed with unsorted household waste. Do not try to dismantle the
system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative cons­equences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and dis­posed of separately in accordance with relevant local and nationl legislation.
IMPORTANT INFORMATION REGA­RDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
R410A
2
FE
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging
1=
2=
1
1+2=
kg
kg
kg
A
B
C
D
5
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper
temperature
Close doors and windows during operation
During cooling operation prevent the penetration of
direct sunlight with
curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller Indoor Body
wipe the air conditioner by using a soft and dry cloth.For serious stains,
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
damage the coating of the unit.
ay
m
Hot water over 40
cause
discoloring or deformation.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is
released
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication
is
completely and left filters are not
may cause defects.
Close the inlet grille.
from the stopper, and remove the filter do
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
O
C(104OF) may
wnw
ard.
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of
the indoor unit.
2.Detach the standard air filter
Slide the knob slightly up release the filter, then withdraw it.
3.Attach Air Purifying Filter
Put air purifying filter appliances into the
right and left filter frames.
ward to
Detach old Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
ATTENTION:
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit.
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will
reduced.
it will be solarized every 6 months.
avoid long time directly sunshine
be
6
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker
Check proper installation of the drainage securely
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
STRICT
ENFORCEMENT
Use the proper voltage
Take care not to damage
the power supply cord.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
Do not channel the air flow directly at people, especially at infants or the aged.
1.Do not use power supply cord extended or connected in halfway
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
3.Do not get the unit exposed
to vapor or oil steam.
Do not insert objects into the air inlet or outlet.
Do not try to repair or reconstruct by yourself.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
STRICT ENFORCEMENT
PROHIBITION
PROHIBITION
Connect the earth cable.
earthing
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
7
Trouble shooting
Cautions
Before asking for service, check the following first.
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after
unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
generated by the casing expanding or shrinking because of temperature changes.
Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation,
indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
In DRY mode, when room temperature becomes lower than temp. setting+2
intermittently at LOW speed
regardless of FAN setting. Is power plug inserted?
Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or
windows left open? Is there any direct sunlight through the window during the
cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?
o
C,unit will run
Normal Performance inspection
Multiple
check
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
In dry mode, speed can’t be changed.
Poor cooling
fan
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
Do not allow children to play with the air
case should children be
swing louver.
or any other things into the
allowed to sit on the outdoor unit.
grille of the air
conditioner
Specifications
The refrigerating circuit is leak-proo f.
The machine is adaptive in following
1.Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Outdoor
(INVERTER)
2. If the power supply cord is damaged, it manufacturer
3. If the fuse of indoor unit on PC board is
it with the type of
broken,change it with the type of
4. The wiring method should be in line with
5. After installation, the power plug should
6. The waste battery should be disposed
7. The appliance is not intended for use persons
8.Young children should be supervised
the appliance.
with
9. Please employ the proper power plug,
cord.
10. A breaker should be incorporated into should be
should be not less than
11 .The power plug and connecting cable
attestation.
12.In order to protect the units,please turn 30 seconds
13.Please don't insert any sensor on 3-way
or its service agent or a similar
without supervision.
all-pole switch and the distance
later, cutting off the power.
Maximum:D.B/W.B
mum:D.B/W.B
Mini
Maximum:D.B/W.B
mum:
Mini Maximum:D.B
mum:
Mini
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B
mum:D.B
Mini
T. 3.15A/ 250V
3mm.
D.B
D.B
must be replaced
broken,please
. If the fuse of
T.25A/250V
the local wiring
be easily reached.
properly.
by young children or
to ensure that th
which fit into the
fixed wiring. The
between
must have
off the A/C first,
stop valve pipe
.In no
situation
32oC/23oC
o
C/15oC
21
o
43
C/26oC
o
18
C
o
C
27 0oC
o
C/18oC
24
o
-
C/-8oC
7
o
24
C/18oC
o
C
-15
qualified
outdoor
p
its two contacts
acquired the local
by the
person.
change
unit is
standard.
infirm
ey
do not play
ower supply
breaker
and at least
fitting.
X
HSU-12HEA103/R2 HSU-18HEA03/R2 HSU-22HEA03/R2 HSU-24HEA03/R2 H2SM-(9+9)HEA03/R2
H2SM-(9+12)HEA03/R2
0.308
0.157
0.271
0.117
0.180
0.237
Remark: EMC testing of this model (HSU-24HEA03/R2) for the use of a magnetic ring power cord, so we recommend users touse the power cord with a magnetic ring.
Componentes y funciones
Unidad interior
Rejilla de la toma de entrada
Toma de entrada
Toma de salida
Generador de aniones (interior)
Alerón horizontal (permite ajustar la dirección del flujo de
aire hacia arriba y hacia abajo; no lo ajuste manualmente)
Recuerde que la ilustración anterior podría no reflejar fielmente el producto adquirido y debe utilizarse únicamente como referencia.
Panel de indicadores
Orificio del receptor de señal
Indicador de REFRIGERACIÓN
Indicador de CALEFACCIÓN
Indicador de TEMPERATURA
Indicador de la función SALUDABLE
(Si la unidad que ha adquirido dispone de función saludable, préstele atención. De lo contrario, ignórelo).
Panel de indicadores
Filtro purificador de aire
Interruptor de emergencia
Pala vertical (permite ajustar la dirección del flujo de aire hacia la izquierda y hacia la derecha)
Panel de indicadores
Indicador del modo seco Indicador de TEMPORIZADOR
DE APAGADO Indicador de TEMPORIZADOR DE ENCENDIDO Indicador de la función SUEÑO
Control remoto
5. Botón RELOJ
6. Botón SALUDABLE
7. Botón MODO
19
8. Botón HORA
9. Botón OSCILACIÓN
10. Botón ENCENDIDO / APAGADO
11. Indicador de TEMPORIZADOR DE ENCENDIDO
12. Indicador de VELOCIDAD DE VENTILADOR
AUTOMÁTICO
ALTA
MEDIA
BAJA
13. Indicador de BLOQUEO
14. Indicador de OSCILACIÓN
15. Indicador de la función SUEÑO
16. Indicador de la función SALUDABLE
17. Indicador de modo de funcionamiento
28
Modo de
AUTOMÁTICO REFRIGERACIÓN SECO
POWER/SOFT
1. CÓDIGO Permite seleccionar el CÓDIGO Ao B. Una vez seleccionado, el código se mostrará en la pantalla LCD. Si no ha recibido instrucciones específicas, seleccione el código A.
2. Botón RESTABLECER Si el control remoto presenta alguna anomalía, introduzca un objeto puntiagudo a través del orificio para pulsar este botón y restablecer el control remoto.
3. Botón LUZ Controla la activación y desactivación de la iluminación del panel de indicadores LED de la unidad interior.
funcionamiento
Control remoto
18. Indicador de envío de señal
19. Indicador de modo INTENSO / SUAVE
30
20. Indicador de dirección de flujo de aire hacia la izquierda / derecha
21. Indicador de TEMPERATURA
22. Indicador de TEMPORIZADOR DE APAGADO
23. Indicador de RELOJ
24. Botón TEMPERATURA
25. Botón VENTILADOR
26. Botón FLUJO DE AIRE SALUDABLE
27. Botón SUEÑO
28. Botón ESTABLECER
29. Botón de modo INTENSO / SUAVE
30. Botón BLOQUEAR Al pulsarlo se deshabilitan los demás botones. Pulse de nuevo este botón para cancelar el bloqueo.
4. Botón TEMPORIZADOR Las siguientes funciones y los indicadores relacionados no están disponibles en este tipo de unidades:
Las siguientes funciones y los indicadores relacionados sólo están disponibles en el modelo HSU-22HEA03/R2ǃHSU-24HEA03/R2:
VENTILADOR
CALEFACCIÓN
Receptor de señal remota
Indicador de la función SALUDABLE
Indicador de TEMPORIZADOR DE APAGADO Indicador de TEMPORIZADOR DE ENCENDIDO Indicador de la función SUEÑO
Indicador de TEMPERATURA
Indicador del modo AUTOMÁTICO
Indicador de REFRIGERACIÓN
Indicador del modo seco
Indicador de CALEFACCIÓN
Unidad exterior
4
TOMA DE SALIDA TUBOS DE CONEXIÓN Y CABLEADO
1
TOMA DE ENTRADA MANGUERA DE DRENAJE
2
Recuerde que la ilustración anterior podría no reflejar fielmente el producto adquirido y debe utilizarse únicamente como referencia.
3
ELÉCTRICO
4
Instalación de las baterías
1. Extraiga la cubierta de las baterías;
2. Instale las baterías como muestra la
ilustración. 2 baterías R-03, botón de restablecimiento (cilindro);
3. Asegúrese de que la polaridad
de las baterías coincide con los símbolos “+” / “-” al instalarlas;
Instale las baterías y vuelva a colocar de nuevo la cubierta.
4.
Nota:
● La distancia entre el cabezal de transmisión de señal y el orificio del receptor debe ser inferior a 7 m sin obstáculos.
● Si se instalan en la habitación lámparas fluorescentes de activación electrónica o de tipo alterno, o bien teléfonos inalámbricos, el receptor podría resultar perturbado al recibir las señales, por lo que la distancia hasta la unidad interior deberá ser menor.
● Si se activan todos los indicadores de la pantalla o no es posible visualizarlos correctamente durante el uso, es señal de que las baterías se han agotado. Por favor, cambie las baterías.
● Si el control remoto no funciona normalmente durante su uso, extraiga las baterías y vuelva a instalarlas pasados unos minutos.
Sugerencia: Extraiga las baterías si no tiene intención de utilizar la unidad durante un periodo largo de tiempo. Si observa alguna pantalla extraña después de extraer las baterías, sólo necesitará pulsar el botón RESTABLECER.
9
Loading...