Haier HSU09XCK, HSU24VCK Operation Manual

Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITIONER OPERATION MANUAL
0010536241
HSU18VCK-G HSU24VCK-G
HSU09XCK-G HSU12XCK-G
PARTS AND FUNCTIONS OPERATION MAINTENANCE
TROUBLE SHOOTING
CAUTIONS
Contents
13
12
14
Índice
PRECAUCIONES
COMPONENTES Y FUNCIONES FUNCIONAMIENTO MANTENIMIENTO
RESOLUCIÓN DE PROBLEMAS
15 16
19
20 21
Table des matières
AVERTISSEMENTS
PIÈCES ET FONCTIONS
MAINTENANCE
DÉPANNAGE
UTILISATION
Outdoor Unit
Loading of the battery
1 2
3
4
Parts and Functions
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote controller
Remove the battery cover;
Load the batteries as illustrated.
2 AAA batteries, resetting key
(cylinder);
" + "/"-";
Load the battery,then put on the cover again.
Note:
Please be subject to the actual produce purchased the above picture is just from your reference
Please be subject to the actual produce purchased the above picture is just from your reference
Air Purifying Filter
(inside)
Inlet
1
Inlet grille
2
Outlet
3
(adjust left and
Vertical blade
right air flow)
4
Display board
Horizontal flap
(adjust up and down air flow.
Don't adjust it manually)
Emergency
Switch
6
7
8
5
1
2
3
4
5
6
7
8
4
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
1. Mode display
2. Signal sending display
4. FAN SPEED display
5. LOCK display
6. TIMER OFF display TIMER ON display
7.TEMP display
15. LOCK button
Used to lock buttons and LCD display
24. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset
21. HOUR button
Operation mode
AUTO FANCOOL DRY
Remote controller
1
2
3
4
5
9
10
11
12
13
14
15 16
21
22
23
24
18
19
20
8
17
7
6
Control the lightening and extinguishing of the indoor LED display board.
8.
9. QUIET button
10. COOL button
11. AUTO button
12. FAN button
13. TIMER button
14. HEALTH button
16. LIGHT button
17. POWER ON/OFF button
18. DRY button
19. TEMP button
20. SWING button
22. EXTRA FUNCTION button
23.CANCEL/CONFIRM button Function: Setting and cancel to the
timer and other additional functions.
3. SWING display
LO MED HI
AUTO
Display circulated
Operation mode
Remote controller
QUITE
POWER
SLEEP
HEALTH
Healthy function is not available for some units.
the remote.
Be sure battery polarity is correct
The distance from the remote to the receiver should be less than 23 feet (7 meters) with no obstructions.
Fluorescent lights or cordless telephones will reduce the range of the remote.
If the display is dim the remote batteries may need to be replaced.
Remote malfunctions can sometimes be corrected by removing the batteries for a few minutes and then replacing them.
Function: Air sending--- Healthy airflow position1--- Healthy airflow position 2 --- Restore the original
--- Right & left air airflow
--- A-B yard--- Sleeping--- Refresh air
(reserved function)
--- Power ---
Fahrenheit/Celsius mode conversion
Additional functions display
flap position
Operation
Air Flow Direction Adjustment
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
3.Fan speed selection
2.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
1.Status display of air flow
When restart after remote turning off, the remote
return to the previous
Move the vertical blade by a knob on air to adjust left and right direction referring to the figure below.
2.Left and right air flow adjustment
(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency operation and test operation
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
changes as
'
AUTO
Note
COOL
DRY
FAN
In DRY mode , when room temperature becomes lower than temp.setting+2
o
C, unit will run
intermittently at LOW speed regardless of FAN
Under the mode of auto operation , air conditioner will automatically select Cool operation according to
room temperature.
conditioner automatically adjusts the fan speed according
When FAN is set to AUTO the air
to room temperature.
In FAN operation mode , the unit will not operate in COOL mode but only in FAN mode, AUTO is not available in FAN mode. And temp.setting is disabled. In FAN mode, sleep operation is not available.
setting.
test operation
switch
Pi
Pi
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the unit beeps once, which means the start of this operation.
When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Designated temperature
Timer mode
Fan
speed
Operation
mode
Above 23oC 26oC AUTO COOL
No
Pi
emergency
operation switch
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
is below 16
o
C, do not use it in the normal operation.
Test operation:
Use this switch in the test operation when the room temperature
from the switch: the cooling operation
Continue to press the test operation
switch for more than 5 seconds.After
you hear two beeps, release your finger
starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor unit will run in high speed.
COOL/DRY:
LOW
MED HI
AUTO
Display circulated
Remote Controller Icon
Operation Mode
Test operation switch is the same as emergency switch.
Operation
Sleep Operation
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
4.Set the wind speed change when sleeping
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 1
O
C
Rises 1
O
C
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
2.
In AUTO mode
3. In FAN mode
It has no SLEEP function.
Note
When TIMER function is set, the sleeping function can’t be set up .After the sleeping function is set u
p
,
TIMER function, the sleeping function will be cancelled; the machine will be in the state of
timing-on.
1 hours after SLEEP mode starts,temp.will become
higher than temp.setting.After another 1 hours,
temp.risesby 1 futher .The unit will run for further 6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
O
C
1
O
C
if user resets
POWER/QUIET Operation
Press button to enter additional options, when cycle display to , will flash. And then press enter to sleep function.
(1)
POWER Operation
(2)
QUIET Operation
Note ˖
When you need rapid heating or cooling, you can use this function.
You can use this function when silence is needed for rest or reading.
During POWER operation, in rapid COOL mode ,
the room
will show inhomogeneous temperature distribution.
Long period QUIET operation will cause effect of not too cool or not too warm.
Press QUIET button, the remote controller will show , and then achieve to the quiet function. Press again this QUIET button , the quiet function will be cancelled.
Press button to enter additional options, when cycle display to , will flashand then press ,enter to power function. When cancel the function, please enter additional options again and to cancel power function.
Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
Remote controller:
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
Timer On/Off On-Off Operation
Healthy airflow Operation
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
3.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille .
Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote controller.
2.In cooling, it is better to select the
mode.
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
3.Press / button to set time.
It can be adjusted within 24 hours.
Hints: After replacing batteries or a power failure happens, time setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
3.The cancel of the healthy airflow function
TIMER OFF-ON
0.5h
0.5h 0.5h
0.5h
Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first 12 hours decreased by 0.5 hour every time, after 12 hours,decreased by 1 hour every time.
After adjust the time,press button and confirm the time ON or OFF button will not flash any more.
4.Confirm timer setting
5.Cancel timer setting Press the timer button by times until the time display eliminated.
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations, to choose the swing location
what you needed,and then press button to confirm.
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations again,and then press button to cancel.
Healthy airflow upwarder
Healthy airflow downwarder
Present position
Maintenance
Setting of proper room temperature
Close doors and windows during operation
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet or outlet
Proper
temperature
During cooling operation prevent the penetration of
direct sunlight with
curtain or blind
OFF
Remote Controller Indoor Body
1.Open the lnlet Grille
2.Detach the standard air filter
3.Attach Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
5.Close the Inlet Grille
Close the Grille surely
Slide the knob slightly up
ward to
release the filter, then withdraw it.
Put air purifying filter appliances into the
right and left filter frames.
Detach old Air Purifying Filter
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
it will be solarized every 6 months.
Prop up the inlet grille by with a grille
ATTENTION:
Please keep the bacteria-killing medium air purifying filter in
avoid long time directly sunshine
when you stop using it,or its ability of sterilization will
be
reduced.
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
support located in the right side of
the indoor unit.
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
the cool and dry conditions
For Smart Use of The Air Conditioner
Replacement of Air Purifying Filter
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit.
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
wipe the air conditioner by using a soft and dry cloth.For serious stains,
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is
from the stopper, and remove the filter do
wnw
ard.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
ay
damage the coating of the unit.
Hot water over 40
O
C(104OF) may
discoloring or deformation.
Once every two weeks
m
cause
released
is
completely
and left filters are not
may cause defects.
the power supply cord and so on.
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
Cautions
Do not attempt to install the air conditioner by yourself because improper works
Connect the earth cable.
earthing
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
1.Do not use power supply cord extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the
operation by disconnecting
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
STRICT ENFORCEMENT
Check proper installation of the drainage securely
WARNING
This system should be installed by a qualified HVAC professional.
may cause fire, water leakage, personal injury or cleath.
Loading...
+ 16 hidden pages