Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Tor que wr ench
Driverƽ
Nipperƽ
Hacksawƽ Pipe cutterƽ
Hole core drillƽ Flaring toolƽ
Spanner(17,19 and 26mm)ƽ Knifeƽ
Gas leakage detector orƽ
soap-and-water solution
ƽ
(17mm ,22 mm ,26mm)
Measuring tapeƽ
Reamerƽ
Power Source
ƽ
Before inserting power plug into receptacle, check the voltage without fail.
The power
Install an exclusive branch circuit of the power.
ƽ
Areceptacleshallbesetupin a distancewherethepowercablecanbe
ƽ
reached.
sourceisthesameasthe
Donotextendthecablebycuttingit.
corresponding name plate.
Drawing for the installation of indoor and outdoor units
ThemodelsadoptHFCfreerefrigerantR410A
more than 5cm
more than
10cm
Indoor Unit
Place,robustnotcausingvibration,wherethebodycanbesupportedsufficiently.ƽ
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
ƽ
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.ƽ
Place,wherecoldaircanbespreadin a roomentirely.ƽ
Place, nearby a power receptacle, with enough space around. (Refer to drawings).ƽ
Place where the distance of more than lm from televisions, radios, wireless apparatuses
ƽ
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
ƽ
receive signals when the fluorescent
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is suf ficiently ventilated.ƽ
Place,possibletobeartheunit,wherevibrationandnoisearenotincreased.ƽ
Place, where discharged wind and noise do not cause a nuisance to the neighbors.ƽ
Place, where a distance markedƽ
Attention must be paid to
the rising up of drain hose
G
Selection of Installation Place
lampsintheroomarelightened.
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Arrangement of piping
directions
Rear left
Left
Below
The marks from to
ƽ
G
inthefigurearethe
parts numbers.
Thedistancebetween
ƽ
the indoor unit and the
floor should be more
than 2m.
A
Rear
right
Right
more than 10cm
more than
60cm
more than 10cm
more than
10cm
more than15cm
F
A
C
Floor fixing dimensions of the
outdoor unit (Unit:mm)
106.5
566
106.5
7
31
Fixing of outdoor unit
Fix the unit to concrete or blockƽ
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
ƽ
surface, roof or rooftop, fix
D
E
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
ƽ
house, fix the unit by attaching a
vibration-proof mat.
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.
NO.0010519573
Accessory parts
Remote controller (1)
R-03 dry battery (2)
Mounting plate (1)
Plastic cap (4)
Ø4X25 Screw
(4)
Drainhose(1)
Cushion (4)
Drain-elbow (1)
Pipe supporting plate (1)
Selection of pipe
Liquid pipe (Ø) 6.35mm(1/4”)
Gas pipe (Ø) 9.52mm(3/8”)
NOTE˖Thethickness of thepipemustbe0.8mm at least.
Indoor unit
FittingoftheMountingPlateand
When the mounting plate is rst xed
1.Carryout,basedontheneighboringpillarsorlintels, a
to be xed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by
weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.
3. Find the wall hole location A using a measuring tape
PositioningofthewallHole
proper leveling for the plate
hanging a thread with a
B= 60mm
[Left·Left-rear piping ]
ƽ
In case of left side piping, cut away, with a nipper, the lid for left piping.
In case of left-rear piping, bend the pipes according to the piping direction to
ƽ
the mark of hole for left-rear piping which is marked on heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2.Inserttheindoor/outdoorelectriccablefrombackside of indoor
out on the front side, then connect them.
3.Coatthearingsealfacewithrefrigerantoilandconnect pipes.
Covertheconnectionpartwithheatinsulationmaterialsclosely,andmakesure
xingwithadhesivetape
Heat insulation
Lid for right
piping
Lid for under piping pipe
Fix with adhesive tape
ƽ
Indoor/outdoor electric cable and drain hose must be bound with refrigerant
piping by protecting tape.
Lid for left piping
material
Drain hose
unit, and pull it
Indoor/outdoor electric cable
Piping
Pipe supporting
plate
[ Other direction piping ]
ƽ
Cut away, with a nipper, the lid for piping according to the piping direction and
then bend the pipe according to theposition of wall hole. When bending, be
careful not to crash
ƽ
Connect beforehand the indoor/outdoor electric cable,
connected to the heat insulation of connecting part specially.
pipes.
andthenpulloutthe
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the
ƽ
mounting plate. Move the body from side to side to verify its
secure xing.
Inordertoxthebodyontothemountingplate,holdup
ƽ
thebodyaslantfromtheundersideandthenputitdown
perpendicularly.
mounting plate
A=145mm
60mm
Ø
B=
A=145mm
Ø
60mm
B=
A=80mm
When themountingplateisxedside barandlintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then
ƽ
fasten the plate to the xed mounting bar.
Refer to the previous article, “ When the mounting plate is
ƽ
position of wall hole.
Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter, slightly descending to outside the wall.
ƽ
Install piping hole cover and seal it off with putty after installation
ƽ
Wall hole
Ø60mm
Indoor side
(Section of wall hole)
Thickness of wall
Piping hole pipe
G
rst xed “, for the
Outdoor side
30mm
30mm
30mm
Unloading of indoor unit body
When you unload the indoor unit,please use
ƽ
your hand to arise the body to leave agraffe,
then lift the bottom of the body outward
slightly and lift the unit aslant until it
leaves the mounting plate.
agraffe
Connectingtheindoor/outdoorElectricCable
Removingthewiringcover
Remove terminal cover at right bottom corner of indoor unit, then takeƽ
offwiringcoverbyremovingitsscrews.
When connecting the cable after installing the indoor unit
1.Insertfromoutsidetheroomcableintoleftside of thewall
hole, in which the pipe has already existed.
2.Pulloutthecableonthefrontside,andconnectthecable
making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back
ƽ
Loosenthescrewsandinsert
ƽ
tighten the screws.
Pull the cable slightly to
ƽ
tightened.
Afterthecableconnection,
ƽ
wiring cover.
side of the unit, then pull it out
the cable ends fully into
make sure the cables have
neverfailtofastentheconnectedcablewiththe
been properly inserted and
mounting plate
on the front side.
terminal block, then
Installation of the Indoor Unit
Drawingofpipe
[Rearpiping ]
Drawpipesandthedrainhose,thenfastenthemwiththeadhesivetape
ƽ
2
When connecting the cable, conrm the terminal number of indoor and
Note
outdoorunitscarefully.Ifwiringisnotcorrect,properoperationcannot
becarriedoutandwillcausedefect.