Haier HSU-09R03H, HSU-12R03H User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09L03/H HSU-09R03/H HSU-12L03/H HSU-12R03/H
Please read this operation manual before using the air conditioner.
No.0010552593
Contents
Cautions Parts and functions Operation
Maintenance Trouble shooting
4-111 12-14
15
Cautions
The machine is adaptive in following situation
I. Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11.The wiring diagram is attached inside the machine.
Maximum: D.B / W.B 32oC/23oC Minimum: D.B / W.B
Maximum: D.B Minimum: D.B Maximum: D.B
Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
18oC/14oC 43oC/26oC
18oC 27oC
15oC 24oC/18oC
-7oC/-8oC
1
Parts and Functions
Indoor Unit
Display board
Display board
Inlet
Anion
(inside)
Vertical flap
(Use remote controller to adjust up and down air flow. Don't adjust it manually)
Horizontal louver
(adjust left and right air flow)
Outdoor Unit
POWER
TIMER
OPERATE
SIGNAL RECEIVING WINDOW
Air filter
(inside)
Inlet grille
Power plug
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE
2
Parts and Functions
Operation
1
2 3
4
13
14
15 16
17
18
19
25. RESET
Used to reset the controller back to normal condition.
26. HEALTH
Used to set healthy operation
Clock set
ON/OFF
MODE SET
FAN
SWING
SLEEP
LOCK RESET
Buttons and display of the remote controller.
1. Mode display AUTO
COOL DRY HEAT FAN
2. SWING display
3. FAN SPEED display
4. HEALTH display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. SLEEP display
12. HEAT display
13. POWER ON/OFF
Used for unit start and stop.
14. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
15. FAN
Used to select fan speed LO, MED, HI, AUTO
16. HOUR
Used to set clock and timer setting.
17. SWING
Used to set auto fan direction.
18. SLEEP
Used to select sleep mode.
19. LOCK
Used to lock buttons and LCD display.
20. TEMP.
Used to select your desired temp.
21. SET
Used to confirm timer and clock settings.
22. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
23. CLOCK
Used to set correct time
24. HEAT
Used to select heat mode.
TEMP
TIMER
CLOCK
5 6
7 8
9
10 12
20
21
22
23
24
25
26
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
4
NOTE: (1)The following functions are not available and (2) Cooling only unit do not have functions and displays related with heating.
LO MED HIAUTO
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
3
Operation
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
«Î—°”√Õ¨“ª∆∑≈∆¡ΩΩ⁄ 7#
µÁ≥ÿ,≥§ ±º‰≤ª”√ ±,Œ™ ∑¿÷𬩓π«ÎΩ´µÁ≥ÿ»°
≥ˆ°£ ‘⁄ π”√÷–»Á”ˆ“Ï≥£,«Î Ω´µÁ≥ÿ»°≥ˆ,6∑÷÷”∫Û‘Ÿ
◊∞»Î–¬µÁ≥ÿ°£
∫£∂˚ºØÕ≈«‡µ∫∫£∂˚ ø’µ˜∆˜”–œfi◊‹π´Àæ
«Î—°”√Õ¨“ª∆∑≈∆¡ΩΩ⁄ 7# µÁ≥ÿ,≥§ ±º‰≤ª”√ ±,Œ™ ∑¿÷𬩓π«ÎΩ´µÁ≥ÿ»° ≥ˆ°£ ‘⁄ π”√÷–»Á”ˆ“Ï≥£,«Î Ω´µÁ≥ÿ»°≥ˆ,6∑÷÷”∫Û‘Ÿ ◊∞»Î–¬µÁ≥ÿ°£
∫£∂˚ºØÕ≈«‡µ∫∫£∂˚ ø’µ˜∆˜”–œfi◊‹π´Àæ
Load the battery:
Be sure that the loading is in line with the" + "/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.