Haier HSU-09LQA13-R2-DB-WT, AS12GB2LAA, HSU-18LEK03-R2-DB, HSU-10LQA13, AS12GS1ERA User Manual

...
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
HSU-10LQA13 HSU-15LQA13 HSU-10LQAB13 HSU-15LQAB13
HSU-09LQA03/R2(DB) HSU-12LQA03/R2(DB) HSU-09LQA13/R2(DB)-WT HSU-09LQA13/R2(DB)-BK HSU-12LQA13/R2(DB)-WT HSU-12LQA13/R2(DB)-BK
HSU-12LEK03/R2(DB) HSU-18LEK03/R2(DB) HSM24HEK03/R2(DB)
AS12GS1ERA AS18GS1ERA
AS12GB2LAA
HSU-10VEK03 HSU-13VEK03 HSU-18VEK03 HSU-24VEK03 AS05GA1LAA AS09GA1LAA AS12GB1LAA AS18GD1LAA
HSU-19CXAR3N HSU-19CXBW3N
HSU-09CK3W3N HSU-09LEK03-Y3 HSU-09CK6G2N HSU-09CK6B2N HSU-12CK3W3N HSU-12CKCS3N HSU-12CK6G2N HSU-12CK6B2N HSU-12CKAG3N HSU-12CKAB3N HSU-18CK3W3N HSU-18CK6B2N HSU-18CK6G2N HSU-18CKBS3N HSU-15CKBS5N HSU-18CKBS5N HSU-18CKAB3N HSU-18CKAG3N HSU-15CKAG5N HSU-18CKCS3N HSU-24CK6B2N HSU-13CXAS5N HSU-13CXAS3N HSU-13CXAR3N HSU-13CXBW3N HSU-19CXBW5N HSU-24CXAS3N HSU-19CXAS5N HSU-19CXAS3N
HSU-12LEK03-Y3 HSU-18LEK03-Y3 HSU-24LEK03-Y2 HSU-09LEK03/R2(DB) HSU-24LEK03/R2(DB) HSU-10LIN13 HSU-09LTS14 HSU-12LTS14 HSU-18LTS14 HSU-24LTS14 HSU-07LEK03
Contents
PARTS AND FUNCTIONS
OPERATION MAINTENANCE CAUTIONS
2 3 6
7 8
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
0010564364
Parts and Functions
Indoor Unit
Inlet
Inlet grille
Nano-Aquo Generator inside
Outlet
Display board
Aureole
Display modethe aureole display different colour when setting different function COOL: blue AUTO: white DRY: cyan
Inlet
Inlet grille
Outlet
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Display board
1
Signal receiver hole
2
ON/OFF display
3
Ambient temp.display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed.
Inlet grille
2
2
Outlet
3
3
Anion generator
4
5
(inside)
7
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
9
Power indicator
10
Timer mode indicator
(Lights up whenTimer operation is selected.)
11
Operation mode indicator
(lights up when the compressor is on.)
12
Remote signal receiver
(A beeping sound is generated when a signal
from remote controller isreceived.)
Ambient temp display
13
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
Actual inlet grille may vary from the one shown in the manual according to the product purchased
2
Vertical blade
(adjust left and
right air fl
1
two sounds.
Inlet
1
1
Vertical blade
6
6
(adjust left and
ight air fl
r
(Lights up when unit starts.)
Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
TEMP display
FAN: yellow
Nano-Aquo
Air Purifying Filter
ow)
Display board
2
3
TIMER ON\OFF display
4
TIMER ON-OFF display SLEEP display
Note to the power failure resume:
press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after hearing
5
COOL\HEAT\Dry\AUTO display
Air Purifying Filter
5
4
12
ow)
Air Purifying
Anion
Filter
generator
(inside)
Vertical blade
(adjust left and
right air fl
: green
(inside)
Emergency
Switch
4
(inside)
8
Emergency
Switch
9 10 11
13
ow)
Remote controller
1
2
3
4
5 9
10
11
12
13
14
15
16
17
TURBO
SWING
HEALTH
TIME ON
/QUIET
SLEEP
TIME OFF
1. Mode display
Operation mode
Remote controller
AUTO
COOL DRY
FAN
2. Signal sending display
3. SWING display
5
4.FAN SPEED display
LO MED HI
Display circulated
AUTO
5. LOCK display
Healthy function is not available for some units.
6. TIMER OFF display
6
TIMER ON display
7. TEMP display
7
Additional functions display
8
8.
Operation mode
Remote controller
QUIET
SLEEP
Supplemented electrical heating
HEALTH
TURBO
9. TURBO/QUIET button
18
19
20
21
FAN button
10.
11. COOL button
12.
SWING LEFT/RIGHT button FAN SPEED button
13.
14. HEALTH display
15. SLEEP display
16.
22
23
24
25
LOCK
17. LIGHT button Control the lightening and extinguishing
of the indoor LED display board.
18. POWER/SOFT display
19. DRY button
button
20. TEMP display
21.
SWING UP/DOWN
22.
TIMER OFF/ON
23.HEALTH AIR FLOW
button
displa
button
24.CANCEL/CONFIRM button Function: Setting and cancel to the
timer and other additional functions.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote.
Outdoor Unit
OUTLET
INLET
CONNECTING PIPING
4
AND ELECTRICAL WIRING
DRAIN HOSE
4
Loading of the battery
Remove the battery cover;
1
Load the batteries as illustrated.
2
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
3
is in line with th
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
type fluorescent lamp or room, the recei
ver is apt to be disturbed in receiving
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
e" + "/"-";
the signals,
Operation
Base Operation
TURBO
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
COOL button:Cooling mode FAN button: Faning mode DRY button: Dehumidify mode
3.Select temp.setting
Press
/
Every time the button is pressed, temp.setting increase 1 rapidly
Every time the button is pressed, temp.setting decrease 1 decrease rapidly
Select a desired temperature.
button
o
C,if kept depressed, it will increase
o
C,if kept depressed, it will
4.Fan speed selection
Press FAN button. For each press, fan speed
changes as
Remote controller:
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation
Mode
AUTO
COOL
DRY
FAN
follows:
LOW
Remote
Controller
MED HI
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature.
according to room
In DRY mode , when room temperature becomes lower
than temp.setting+2
speed regardless of FAN setting.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in
FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available.
/QUIET
2
SWING
HEALTH
TIME ON
1
1
3
4
2
3
SLEEP
TIME OFF
Display
circulated
AUTO
Note
temperature.
o
C, unit will run intermittently at LOW
FAN mode, AUTO is not available in
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Above 23oC 26oC AUTO COOL
Designated temperature
Timer mode
No
Fan
speed
Operation
mode
Pi
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16 normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice, your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
o
C, do not use it in the
release
Pi Pi
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1
Initial state
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
2.Left and right air flow adjustment
For each press of button, remote controller displays as follows :
remote controller:
Pos.1
Pos.5
Pos.2
Pos.6
Pos.3
Pos.4
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur adjusted to left or at air outlet if all vertical louvers are right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note: When restart after remote turning off, the remote controller
controller will automatically memorize the previous set swing position.
swing)
(Auto
mode ,
3
Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
higher than temp.setting.After another 1 hours,temp.rises
O
C
by 1 futher.The unit will run for further
T
emp. is higher than temp.setting so that room temperature
6 hours then stops
won’t be too low for your sleep.
O
C
1
Note
When TIMER function is set, the sleeping function can’t be
if user resets
p
set up .After the sleeping function is set u TIMER function, the sleeping function will be cancelled; the
machine will be in the state of
timing-on.
,
TURBO/QUIET Operation
TURBO
/QUIET
TURBO
/QUIET
When you need fast cool or fast dehumidification,you can
choose the Turob function; when you sleep, read, you can
choose Quiet function
Press the
TURBO
bu on, you can switch the “Turbo” and “Quiet”
/QUIET
SLEEP operation starts SLEEP operation stops
Approx.6hrs
O
C
Rises 1
Rises 1
O
C
Unit stop
1 hr
1 hr
Temp.setting
In COOL, DRY mode
In AUTO mode
2.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation
3. In FAN mode
It has no SLEEP function.
mode.
will swith as below
TURBO
QUIET
cancel
When running in Turbothe fan speed is the highest,
when running in Quiet, the fan speed is super slow
HEALTH Operation
Nano-Aqua generator adopt two high voltage pole to ionize the water molecule into nanometer water ion,and release these ions to the air to kill the bacterium and refresh the air. as well as the nanometer water inon can be easily absorbed by skin,keeping moisture
4.Set the wind speed change when sleeping If the wind speed is high or middle before setting for the
sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
4
anytime.
Operation
Timer On/Off On-Off Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
0.5h
TIMER ON TIMER OFF TIMER ON-OFF
0.5h 0.5h
0.5h
TIMER OFF-ON
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press / button to set time.
Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time.
BLANK
Health airflow Operation
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Press button to select “ Healthy airflow”, the remote
controller will switch as below
Healthy airflow upwarder
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly,
stop for a minute and then start, adjusting by remote
controller.
Note:
Healthy airflow downwarder
fixed
location
Press the button for each time, settiing time in the first 12 hours decreased by 0.5 hour every time, after 12 hours,decreased by 1 hour every time.
It can be adjusted within 24 hours.
4.Confirm timer setting
After adjust the time,press button and confirm the
time ON or OFF button will not flash any more.
5.Cancel timer setting Press the timer button by times until the time display
eliminated.
Hints: After replacing batteries or a power failure happens, time setting should be reset.
According to the Time setting sequence of TIMER ON or
1.After setting the healthy airflow function, the position
grill is fixed.
2.In cooling, it is better to select the
mode.
3.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may
occur at the grille .
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
5
Maintenance
6
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper
temperature
Close doors and windows during operation
During cooling operation prevent the penetration of
direct sunlight with
curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller Indoor Body
wipe the air conditioner by using a soft and dry cloth.For serious stains,
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
damage the coating of the unit.
ay
m
Hot water over 40 cause
discoloring or deformation.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is
released
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication
is
completely and left filters are not
may cause defects.
Close the inlet grille.
from the stopper, and remove the filter do
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
O
C(104OF) may
wnw
ard.
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of the indoor unit.
2.Detach the standard air filter
Slide the knob slightly up release the filter, then withdraw it.
3.Attach Air Purifying Filter
Put air purifying filter appliances into the
right and left filter frames.
ward to
Detach old Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
ATTENTION:
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit.
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will
reduced.
it will be solarized every 6 months.
avoid long time directly sunshine
be
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker
Check proper installation of the drainage securely
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
ENFORCEMENT
Use the proper voltage
Take care not to damage
the power supply cord.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
Do not channel the air flow directly at people, especially at infants or the aged.
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
STRICT ENFORCEMENT
1.Do not use power supply cord extended or connected in halfway
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not operate the switch with wet hand.
Connect the earth cable.
earthing
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
7
Trouble shooting
Cautions
Before asking for service, check the following first.
Cause or check points
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system.
When the electric plug is pulled out and reinserted, the protection circuit
will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after
unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is generated by the casing expanding
or shrinking because of temperature changes. Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist.
This is due to the sudden cooling of indoor air.
In DRY mode, when room temperature
becomes lower than temp.
setting+2
intermittently at LOW speed
regardless of FAN setting.
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or
windows left open? Is there any direct sunlight through the window during the
cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?
o
C,unit will run
Normal Performance inspection
Multiple
check
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
In dry mode, speed can’t be changed.
Poor cooling
fan
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
Do not allow children to play with the air
case should children be
swing louver.
or any other things into the
allowed to sit on the outdoor unit.
grille of the air
conditioner
Specifications
The refrigerating circuit is leak-proo f.
The machine is adaptive in following
1.Applicable ambient temperature range:
Indoor
Cooling
2. If the power supply cord is damaged, it manufacturer
3. If the fuse of indoor unit on PC board is
it with the type of
broken,change it with the type of
4. The wiring method should be in line with
5. After installation, the power plug should
6. The waste battery should be disposed
7. The appliance is not intended for use
persons
8.Young children should be supervised
the appliance.
with
9. Please employ the proper power plug, cord.
The power plug and connecting cable
10. attestation.
11.In order to protect the units,please turn
30 seconds
Outdoor
or its service agent or a similar
without supervision.
later, cutting off the power.
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:
T. 3.15A/ 250V
D.B
must be replaced
broken,please
. If the fuse of
T.25A/250V
the local wiring
be easily reached.
properly.
by young children or
to ensure that th
which fit into the
must have
off the A/C first,
situation
32oC/23oC
o
21
C/15oC
o
46
C/26oC
o
18
C
qualified
outdoor
acquired the local
.In no
person.
change
unit is
standard.
ey
do not play
p
ower supply
and at least
by the
infirm
Haier
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010
Website: www.haier.com
8
Loading...