Haier HSU-09LF03, HSU-12LF03 User Manual

Installation Manual of Room Air Conditioner
Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1.Driver cksaw
2.Ha
3.Hole core d
rill
Accessory parts
No. Accessory parts
1
2
3
4
5
6
Remote controller
R-03 d
Mounting plate
Drain hose
Steel nail, cement
4X25
Screw
Plastic cap
ry battery
4X50
Number of articles
1
2
1
1
6
4
5.
Torque wrench(17mm,22mm,26mm)
6.Pipe cutter ring tool
7.Fla fe
8.Kni
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
mc5 na
h
t er
om
Optional parts for piping
Mark
A
B
C
D
E
F
G
Parts name
Non-adhesi
Adhesive tape
Saddle(L.S) with scr
Connecting elect for indoor and outdoor
Drain hose
Heating insulating material
Piping hole c
ve tape
ews
ric cable
over
m
o
r
e
t
h
a
n
1
0
c
m
Attention must be paid to the rising up of drain hose
m
o
r
e
t
h
a
n
1
c0
m
A
1
1
4
1
1
10
11
7
8
9
Drain-elbow
Cover
Cushion
Pipe supporting plate
Connecting cable
Note:Cooling only units don't have Drain-elbow
No.0010518285
Arrangement of piping directions
Rear left
Below
Rear right
Right
Left
m
c
0
1
n
a
h
t
e
r
o
m
m
o
r
e
t
h
a
n
1
0
c
m
m
c
0
6
n
a
h
t
e
r
o
m
A
The marks from to in the figure are the parts numbers.
G
The distance between the indoor unit and the floor should be more than 2m.
C
D
m
o
r
e
t
h
a
n
1
5
c
m
140 140415
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-09LF03 HSU-12LF03
082
Fixing of outdoor unit
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.
If vibration may a
Indoor Unit
Place, robust not causing vibration, where the body can be supported
fficiently.
su Place, not a inlet and outlet of the unit are not disturbed. Place, possible to drain easi outdoor unit. Place, where cold air can be spread in a room entire Place, nearby a power receptacle, with enough space around. (Refer to drawings). Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
ffected by heat or steam generated in the vicinity, where
Selection of Installation Place
ly, where piping can be connected with the
ly.
ffect the house, fix the unit by attaching a vibration-proof mat.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is
fficiently ventilated.
su Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrate in the above figure.
Power Source
Before inserting power plug into receptacle, check the voltage without fail
Install an exclusive branch circuit of the pow
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
er.
. The power source is the same as the corresponding name plate.
d
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
For 09
Liquid pipe ( )
Gas pipe ( ) 9.52mm(3/8")
6.35mm(1/4")
2
For 12
6.35mm(1/4")
12.7mm(1/2")
Indoor unit
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
B= 60mm
A=145mm
30mm
When the mounting plate is fixed side bar and lintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten
the plate to the fixed mounting bar.
Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
Indoor side
Wall hole
60mm
(Section of wall hole)
G
Piping hole pipe
Outdoor side
Thickness of wall
3.Installation of the Indoor Unit
Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
3
Loading...
+ 5 hidden pages