Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
1.Driver
cksaw
2.Ha
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No. Accessory parts
1
2
3
4
5
6
Remote controller
R-03 d
Mounting plate
Drain hose
Steel nail, cement
4X25
Screw
Plastic cap
ry battery
4X50
Number
of
articles
1
2
1
1
6
4
5.
Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
ring tool
7.Fla
fe
8.Kni
9.Nipper 12.Reamer
10.Gas leakage detector or
soap-and-
water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
mc5na
h
ter
Optional parts for piping
Mark
A
B
C
D
E
F
G
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with scr
Connecting elect
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole c
ews
ric cable
over
om
r
hte
a
n
1
0
c
m
om
Attention must be paid to
the rising up of drain hose
m
o
r
e
t
h
a
n
1
0
c
m
A
1
1
4
1
1
10
11
7
8
9
Drain-elbow
Cover
Cushion
Pipe supporting plate
Connecting cable
Note:Cooling only units don't have Drain-elbow
No.0010518787
Arrangement of piping directions
Rear left
Below
Rear
right
Right
Left
m
c
m
ro
e
t
nah
1
0
c
m
m
c
0
6
n
a
h
t
er
om
A
The marks from to in the figure are the parts numbers.
G
01n
ah
te
rom
om
The distance between the indoor unit and the floor should be
more than 2m.
C
D
E
r
hte
a
1n
5
mc
280
140 140415
Floor fixing dimensions
HSU-09LEK13
HSU-12LEK13
HSU-07LEK03
HSU-07HEK03
HSU-09LB11T
HSU-09LD11T
HSU-12LB11T
HSU-12LD11T
HSU-09LEK03
HSU-12LEK03
HSU-09HEK03
HSU-24HH03
HSU-24HEG03
HSU-24LH03
HSU-24LEK03-Y5
of the outdoor unit
(Unit:mm)
HSU-12HEK03
HSU-05LEK03-Y
HSU-07LEK03-Y
HSU-09LEK03-Y
HSU-12LEK03-Y
HSU-09LEK03-Y2
SAS-09HEK3
SAS-12HEK3
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-09LEK03/ (DB)
HSU-12LEK03/ (DB)
HSU-108CH09
HSU-138CH09
HSU-12LEK13-M
HSU-09LEK03-Y3
HSU-12LEK03-Y3
HSU-18LEK03-Y3
HSU-18LEK03-Y
HSU-12LEK03-Y2
HSU-18LEK03-Y2
HSU-09CK2S3
HSU-12CK2S3
HSU-18HEK03
HSU-18LEK03
HSU-18LK2S3
HSU-18LB11T
HSU-18LD11T
HSU-18LD11
HSU-18LB11
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
140
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-09LB11
HSU-09LD11
HSU-12LD11
HSU-12LB11
HSU-18LEK13
HSU-09CK2W3
HSU-09CK6B3
HSU-12CK2W3
HSU-12CK6B3
HSU-18LK2W3
HSU-18LK6B3
SAS-18HEK3
HSU-09LEK03-Y5
HSU-12LEK03-Y5
HSU-09LH03
HSU-12LH03
HSU-09HH03
HSU-12HH03
500
140
HSU-09HEG03
HSU-12HEG03
Selection of pipe
For 07 09 108
Liquid pipe ( )
Gas pipe ( ) 9.52mm(3/8")
6.35mm(1/4")
256
HSU-24LK2S3
HSU-24LEK13
HSU-22LB11
HSU-22LD11
HSU-24LD11T
HSU-18LEK03/ (DB)
HSU-24LEK03-Y2
HSU-24LEK03-Y3
HSU-24HEK03
SAS-24HEK3
HSU-18HH03
HSU-18HEG03
For 12 18 138
6.35mm(1/4")
12.7mm(1/2")
113.5
583
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-18LEK03-Y5
HSU-18LH03
HSU-18LEK03-Y6
For 24
HSU-18LEK03-Y5(6)
HSU-18LH03
9.52mm(3/8")
15.88mm(5/8")
113.5
.
19 5
3
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
24K
18K
HSU-12LEK03-Y5(6)
HSU-12LH03
A=145mm
B=
A=145mm
9K 12K
HSU-108CH09
HSU-138CH09
B= 60mm
A=145mm
30mm
HSU-18HH03
HSU-18HEG03
HSU-18LEK03-Y6
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
B= 60mm
30mm
60mm
30mm
Make a hole of 60 mm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation
Indoor side
Wall hole
60mm
(Section of wall hole)
2
G
Piping hole pipe
Outdoor side
Thickness
of wall