Haier HSU-09LEA13-H - annexe 1, HSU-12LEA13-H, HSU-14LEA13-H, HSU-09LEB13-H, HSU-12LEB13-H Operation Manual

...
Please read this operation manual before using the air conditioner.
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
0010515267
HSU-09LEB13-H HSU-12LEB13-H HSU-14LEB13-H
HSU-09LEA13-H HSU-12LEA13-H HSU-14LEA13-H HSU-18LEA13-H
5
Parts and Functions
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Outdoor Unit
Actual inlet grille may vary from the one shown in the manual according to the product purchased
HSU-09LEB13-H
HSU-12LEB13-H HSU-14LEB13-H
HSU-09LEA13-H HSU-12LEA13-H HSU-14LEA13-H
HSU-18LEA13-H
Display board
Inlet
Air Purifying Filter
Horizontal flap (adjust up and down air flow. Don't adjust it manually)
Air filter(inside)
Inlet grille
Power plug
(inside)
Outlet
(adjust left and right air flo
Vertical blade
4
4
6
Parts and Functions
ON/OFF
TEMP
MODE SET
FAN
TIMER
SWING
CLOCK
SLEEP
LOCK RESET
5
6
7 8
9
10
19
20
21
22
23
1
2 3
11
12
13
14
15
16
A U T O
ON OFF
AM PM
o
C
17
18
1. Operation mode display
2. SWING display
3. FAN SPEED display
LO MED HIAUTO
5. SLEEP display
6. LOCK display
7. SIGNAL SENDING display
8. TIMER OFF display
9. TIMER ON display
10. CLOCK display
11. TEMP display
12. POWER ON/OFF
Used for unit start and stop.
13. MODE
Used to select
AUTO run, COOL,
DRY and FAN operation
15. HOUR
Used to set clock and timer setting.
16. SWING
Used to set auto fan direction.
17. SLEEP
Used to select sleep mode.
18. LOCK
Used to lock buttons and LCD
display.
19. TEMP.
Used to select your desired temp.
20. SET
Used to confirm timer and clock settings.
21. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
22. CLOCK
Used to set correct time
23. RESET
normal condition.
Used to reset the controller back to
Hints:
After replacing with new batteries, remote controller will conduct self-check, displaying
all information on LCD. Then, it will become normal.
Display board
24
24.
Singal receiver hole
25. Ambient temp.display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
25
14. FAN
Used to select fan speed LO, MED, HI, AUTO
1
8
9
1
Remote controller
Clock set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
5
Operation mode
AUTO
FAN
COOL DRY
Remote controller
Display board
7
Operation
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the
room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
Load the battery:
Be sure that the loading is in line with the" + "/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is
supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode,
the air conditioner is not desired for use in a long period, please shut off the power
supply in case that the unit automatically resume operation when power is re-supplied,
or press ON/OFF to turn off the unit when power resumes.
if