Haier HSU-09LEA03-N User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09LEA13-F HSU-12LEA13-H HSU-18LEA13-H HSU-12LEA13-F HSU-12LEA13-M HSU-18LEA13-M HSU-07HEA03 HSU-09HEA03 HSU-12HEA03 HSU-18HEA03 HSU-22HEA03 HSU-24HEA03 HSU-12LEB13-H HSU-14LEB13-H HSU-09CRA03-T AMS09H03-N AMS12H03-N AMS18H03-N AMS22H03-N PAS18L03-N(T3) HSU-12HEA03/(DB) HSU-09HEA03/(DB)
HSU-18LEA03(T3) HSU-18LEA13(T3)
HSU-18HEA13(T3) HSU-18HEA03(T3) YKS-09HEA03 YKS-12HEA03 YKS-18HEA03 HSU-12HEB03 HSU-09LEA03-N HSU-10LED03-T
HSU-13LED03-T HSU-18LED03-T HSU-12HEC03 HSU-09HEC03
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
1 2-4
5
6.7
TROUBLE SHOOTING
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010522564
7
Parts and Functions
TIMER
CLOCK
SET
SLEEP
LOCK
RESET
Indoor Unit
1
2
3
7
5
4
1
1
Inlet
2
2
Inlet grille
3
3
Air Purifying Filter (inside)
5
4
Outlet
Actual inlet grille may vary from the one shown in the manual according to the product purchased
8
Display board
3
1
1
Signal receiver hole
COOL display
2 3
HEAT display
Ambient temp.display
4
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
2
5
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
6
6
Vertical blade
(adjust left and right air flow)
7
Anion generator
4
5
HEALTH display
5
(If the unit which you purchased
has healthy function,follow it.
If not,please ignore.)
6
Dry display
TIMER OFF display
7
TIMER ON display SLEEP display
6
7
4
5
6
8
(inside)
Remote controller
1
2
5
3
23
23
13
18
12
21
19
17
1. Operation mode display
Operation mode
Remote controller
Display board
2. SWING display
3.FAN SPEED display
NOTE:
Cooling only unit do not have displays and functions related with heating
If the unit which you purchased has healthy function,follow it.If not,please ignore.
HEALTH
TIMER
CLOCK
LOCK
AUTO
ON/OFF
FAN
MODE
SWING
SET
COOLDRY
SLEEP
RESET
LO MED HIAUTO
HEAT
FAN
Loading of the battery
4. SLEEP display
10
5. LOCK display
6
6. SIGNAL SENDING
7
7.TIMER OFF display
8
8. TIMER ON display
9. CLOCK display
9
10. TEMP display
4
11. POWER ON/OFF
11
15
20
14
16
22
Used for unit start and stop.
12. MODE Used to select AUTO run,
COOL,DRY,HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR Used to set clock and timer setting.
15. SWING Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and
LCD display.
18. TEMP.SETTING Used to select your desired
temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER Used to select TIMER ON,
TIMER OFF,TIMER ON-OFF
21. CLOCK Used to set correct time
22. RESET Used to reset the controller back to normal condition.
23. HEALTH
Used to operate the healthy
. noitcnuf
Outdoor Unit
OUTLET
INLET
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
"AM "and "PM" stop flashing,while clock starts working.
1
After time setting is confirmed,press SET,
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
14
will increase
button is kept pressed,time will
Remove the battery cover;
1
2
Load the batteries as
2
illustrated. 2 R-03 batteries,
1
resetting key(cylinder);
3
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals, so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation,
please
remove the batteries and
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
after taking-out, just need to press reset key
Be sure that the loading
3
is in line with th
e" + "/"-";
Please change batteries.
reload several minutes later.
Operation
ON/OFF
FAN
HEALTH
FAN
MODE
SWING
ON/OFF
HEALTH
FAN
MODE
FAN
MODE
SWING
FAN
MODE
SWING
FAN
MODE
SWING
FAN
MODE
SWING
FAN
MODE
SWING
Unit start / stop
Press ON/OFF button, unit starts or stops.
Select temp.setting
Operation Mode
AUTO
COOL
DRY
HEAT
FAN
Display Board
nothing
Remote Controller
Note
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner according to room
In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
When FAN is set to AUTO, the
automatically adjusts the fan speed
temperature.
o
C,unit will run intermittently
Auto Operation
According to the automatic choice system in temperature in indoors
cold or make the hot movement
Dry Operation
Cool Operation
Heat Operation
Note:
In DRY mode, when room temperature becomes lower than temp.
setting+2 C, unit will run intermittently at LOW speed regardless of FAN setting.
o
Fan Operation
1.
When FAN is set to AUTO, the air conditioner automatically adjusts
the fan speed according
AUTO LO MED HI
to roomtemperature.
2.In FAN operation mode the unit will not operate
in COOL mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
Air Flow Direction Adjustm
(1)
Note:
In HEAT mode,warm air will blow out after a short periodof the time
due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts
the fan speed according to room temperature.
Cooling only unit do not have displays and functions related with heating
Remote controller can memorize each operation status. When starting it next time,just press ON/OFF button and unit will run in previous status.
2
Loading...
+ 5 hidden pages