REMOTE CONTROLLER
Signal ejecting window
It sends signals to the indoor unit.
DISPLAY button
Press it once to stop the indoor unit displaying and press again to make it display.
SLEEP button
Please see“sleep mode”.
OPERATION MODE button
Press it to select operation mode:
COOL
AUTO
Press it once, the setting tempera-
-ture decreases by 1 .The range of
setting temperature is 16-31 .
Press it to change the fan speed in the order of low-medium-high
-auto ( ).
Please see“adjustment of air flow direction”.
HEAT
TEMPERATURE ADJUSTMENT buttons
FAN SPEED button
UP&DOWN SWING
FAN
AUTO
button
DRY
SLEEP
123
AUTO
SWING
DISPLAY
FAN AUTO
TIMER
MODE
I/O
FAN SPEED
INOIZER
hours OnOff
SWING
/CL.
¡æ
TURBO
NOTICE:
Cool only type has no HEAT mode. To operate, the distance should be within 6 meters from the indoor unit with a clear line of sight. Remove the batteries if the remote controller is not to be used for long periods of time. As this is a all-purpose remote controller which contains many functional buttons, please refer to the function of the air conditioner to know about the actual function. Don't tear the batteries apart or throw them into fire, which will lead to irreparable damage.
When transferring from one mode to another, it may needs less than 3 minutes’ delay to protect compressor.
1
OPERATION DISPLAY
It displays the current settings.
TIMER SET/CLOCK button
Press it to fix the timer setting or
set the clock to the present time.
TURBO button
Press it to start turbo function and press again to stop it.
RUN/STOP button
Turns unit ON/OFF.
TEMPERATURE ADJUSTMENT buttons
Press it once, the setting tem-
-perature increases by 1.
LEFT&RIGHT SWING
Please see“adjustment of air flow direction”.
Press it to start inoizer function and press again to stop it.
button
INOIZER button
TIMER&SET OPERATION
Timer operation
ON/OFF timer operation set
when the air conditioner is on or off to initiate the
Press button Timer/CL OFF or ON TIMER function. Every press of button Timer/ increases the ON/OFF time by one hour(24 hours at most).
to
If you want timer operation cancelled, press button Timer/ until the icon
of timer“ ”,the time and “hours on” or “hours off” disappear on the remote
controller display.
Note: When the air conditioner is on timer operation,if you want to reset the timer you must cancel the former timer, or the setting will not in accord with actual condition.
Clock set
As long as the remote controller is on power, the clock will run all the time and it can be adjusted in any condition even when the air conditioner is off. While the air conditioner is electrified for the first time, the time of the clock is “ 0:00 ”, the flash of “: ” means the clock counts the time automatically. Press the button “Timer/ ” for 3 seconds, the time of the clock can be adjusted. At that time the time of hour flashes, during this period you can add the time of hours by pressing the button “ ” and reduce the time by pressing the button“ ”. After setting the time of hour, press the button Timer/ again to adjust the time of minute(do not need to press it for 3
CL
seconds).When the time of minute flashes, press the button“ ” to add the time of minute, and press the button “ ” to reduce it. Finish setting the time of minute, press the button “Timer/ ” for the third time to confirm the time of the clock.
Note: The time of the clock will only display when the air conditioner isn't set timer, otherwise it will not display.
¡±
¡±
¡±
¡±
CL
CL
CL
CL
2
¡±
¡±
OPERATION MODE ADJUSTMENT
AUTO mode
1.
In this mode, the air conditioner can automatically adjust the room
temperature to decide the most suitable temperature. At the start of
operation, the air conditioner will automatically select the operation mode
according to the room temperature. The following table shows the conditions which are set at start up.
Room
Temperature (RT)
RT26 26 RT 25
25 RT 23
Rt 23
COOL mode
2.
Press UP & DOWN SWING button to change up/down air flow direction and LEFT & RIGHT SWING button to change left/right air flow direction. Press FAN SPEED button to change the fan speed of indoor unit.
Press TEMPERATURE ADJUSTMENT button to change the set temperature.
DRY mode
3.
In this mode, the air conditioner automatically sets the room temperature
and this temperature will not appear on display.
TEMPERATURE ADJUSTMENT button and FAN SPEED button are not functional. Press UP & DOWN SWING button or LEFT & RIGHT SWING button to change air flow direction.
FAN mode
4.
In this mode, the outdoor unit does not operate. The indoor fan alone operates.
Press UP & DOWN SWING button or LEFT & RIGHT SWING button to change air flow direction.
Press FAN SPEED button to change the fan speed of indoor unit.
AUTO
Cool only type
Initial Setting Temperature
Mode
Cool
Dry
24 RT-2
RT-2 21
Heat pump type
Mode
Initial Setting Temperature
Cool
Dry
Heat
24
RT-2
RT-2
26
3
5. HEAT mode (only applied to heat pump type)
¡± ¡±
Press MANUAL SWING button or SWING button to change up/down air flow direction.
Press FAN SPEED button to change the fan speed of indoor unit.
Press TEMPERATURE ADJUSTMENT button to change the set temperature.
6. TURBO function (only applied to turbo series)
This function will make the air conditioner heat or cool quickly and during this period, the noise of the air conditioner will increase. Turbo function can be only started up in heat or cool mode(turbo heating or turbo cooling) otherwise, it can not be started up. When the air conditioner is in cool or heat mode, press turbo button to initiate turbo function, the remote con-
-troller displays “TURBO and the icon of fan speed is “ ”,meanwhile the air conditioner cannot be controlled by the remote controller. Press turbo button again or start up sleep mode or transit modes to exit turbo function. After exiting turbo function the fan runs at low speed.
7. ADJUSTMENT OF AIR FLOW DIRECTION
UP & DOWN SWING function
Every press of the UP & DOWN SWING button, the angle of the
up and down swing louver will change in the order of
. When it swings automatically, the
swing icon displays dynamically, meanwhile the letter
SWING
SWING“”
displays above the icon.
LEFT & RIGHT SWING function(only applied to left
& right swing series)
Every press of the LEFT & RIGHT SWING button, the angle of the
swing louver will change in the order of
. When it swings automatically, the swing icon displays
SWING
dynamically, meanwhile the letter displays above the icon.
SWING“”
4
SLEEP mode
8.
Normal sleep
When the air conditioner is in cooling and dry mode, the indoor fan runs at low speed.After one hour of operation the set temperature will increase by 1 .One hour later, the set temperature will increase by 1 once more.The unit will then continue operating at 2 above the set temperature.
When the air conditioner is in heating mode , the indoor fan runs at low speed. After one hour of operation the set temperature will decrease by 2 . One hour later, the set temperature will decrease by 2 once more. The unit will then continue operating at 4 below the set temperature.
Sleep mode 1
When the air conditioner is in cooling and dry mode and 23 st 16 , during the 3 hours after sleep mode 1 start up ,the set temperature will increase by 1 every hour .The unit will continue operating at 3 above the set temperature. 8 hours later, the set temperature will decrease 2 . The unit will then continue operating at this temperature.
When 24 st 27 , during the 2 hours after sleep mode 1 start up, the set temperature will increase by 1 every hour .The unit will continue operating at 2 above the set temperature.8 hours later, the set temperature will decrease 2 ,the unit will continue operating at this temperature.
When 28 st 31 ,the unit will operate at the set temperature all along.¡æ¡æ
When the air conditioner is in heat mode and18 st 16 , the unit will ¡æ¡æ operate at the set temperature all along.
When 19 st 25 , during the 2 hours after sleep mode 1 start up, the set temperature will decrease by 1 every hour. The unit will continue operating at 2 below the set temperature.8 hours later, the set temperature will increase 2 , the unit will continue operating at this temperature .
When 26 st 31 , during the 3 hours after sleep mode 1 start up, the set temperature will decrease by 1 every hour. The unit will continue operating at 3 below the set temperature.8 hours later, the set temperature will increase 2 .The unit will then continue operating at this temperature.
¡æ¡æ
¡æ¡æ
¡æ¡æ
123
1
¡æ¡æ
Sleep mode 2
When the air conditioner is in cooling and dry mode and 23 st 16 , during the 3 hours after sleep mode 2 start up ,the set temperature will increase by 1 every hour .The unit will continue operating at 3 above the set temperature.7 hours later, the set temperature will decrease 1 . The unit will then continue operating at this temperature.
When 24 st 27 , during the 2 hours after sleep mode 2 start up, the set temperature will increase by 1 every hour .The unit will continue operating at 2 above the set temperature.7 hours later, the set temperature will decrease 1 ,the unit will continue operating at this temperature .
When 28 st 31 ,the unit will operate at the set temperature all along.¡æ¡æ
When the air conditioner is in heat mode and18 st 16 , the unit will ¡æ¡æ operate at the set temperature all along.
When 19 st 25 , during the 2 hours after sleep mode 2 start up ,the set temperature will decrease by 1 every hour .The unit will continue operating at 2 below the set temperature.7 hours later, the set temperature will increase 1 , the unit will continue operating at this temperature .
When 26 st 31 , during the 3 hours after sleep mode 2 start up, the set temperature will decrease by 1 every hour. The unit will continue operating at 3 below the set temperature. 7 hours later, the set temperature will increase 1 .The unit will then continue operating at this temperature.
Sleep mode 3
When the air conditioner is in cooling and dry mode and 23 st 16 , during the 3 hours after sleep mode 3 start up, the set temperature will increase by 1 every hour .The unit will continue operating at 3 above the set temperature.
When 24 st 27 , during the 2 hours after sleep mode 3 start up, the set temperature will increase by 1 every hour .The unit will continue operating at 2 above the set temperature.
When 28 st 31 ,the unit will operate at the set temperature all along.¡æ¡æ
When the air conditioner is in heat mode and18 st 16 , the unit will ¡æ¡æ operate at the set temperature all along.
2
¡æ¡æ
¡æ¡æ
¡æ¡æ
¡æ¡æ
3
¡æ¡æ
¡æ¡æ
5
When 19 st 25 , during the 2 hours after sleep mode 3 start up ,the set temperature will decrease by 1 every hour. The unit will continue operating at 2 below the set temperature.
When 26 st 31 ,during the 3 hours after sleep mode 3start up, the set temperature will decrease by 1 every hour. The unit will continue operating at 3 below the set temperature.
INOIZER function(only applied to inoizer series)
Press inoizer button to start or stop inoizer function when the air
conditioner is on or set timer.
displays “ ” while it is initiated and extinguishes while it stops.
This function can only be stopped by pressing inoizer button or
turning off the air conditioner.
¡æ¡æ
¡æ¡æ
The DISPLAY of the remote controller
6
7
8
KY-46B
Loading...