Haier HSU-09H13, HSU-12H13 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09H13
HSU-12H13
Please read this operation manual before using the air conditioner.
No.0010501517
Caution
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
1
Caution
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Specifications
The refrigerating circuit is leak-proof. Remark per EMC Directive 89/336/EEC. To prevent flicker impression during the start of the compressor(Technical Process) and the adversely influence caused by the 2nd harmonies of compressor following installation conditions do apply:
1.The power connection for air conditioner has to be done at the main power distribution.This distribution has to be of a Iow impedance. Normally the required impedance is reached at a 32A fusing point.
2.No other equipment has to be connected: to this power line.
3.For the details installation acceptance please refer to your contract with the power supplier, if restrictions do apply for products: like washing machines,air conditioners or electrical ovens.
4.For the details of the power of air, conditioner, please refer to the rating plate of the product.
5.For any question contact your local dealer.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
2
Caution
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter. 11 .The wiring diagram is attached inside the machine.
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
32oC/23oC 18oC/14oC
43oC/26oC 18oC
27oC 15oC
24oC/18oC
-7oC/-8oC
3
Parts and Functions
Indoor Unit
Test running switch(manual)
Used only for test running in cooling
Inlet grille
when room temp. is below 16oC. Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Remote signal receiver
Air filter
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Power indicator
Lights up when unit starts. Lights up when Timer operation
Timer mode indicator
is selected.
A beeping sound is generated when a signal from remote controller is received.
Operation mode indicator
Lights up during compressor running.
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Outdoor Unit
OUTLET
INLET
HSU-09H13 HSU-12H13
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Parts and Functions
Operation
1
2 3
4
11
12
13 14
15
16
17
Clock set
ON/OFF
MODE SET
FAN
SWING
SLEEP
LOCK RESET
Buttons and display of the remote controller.
1. Mode display AUTO
COOL DRY HEAT FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFFdisplay
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to
normal condition.
AUTO
TEMP
TIMER
CLOCK
5 6
7
8
9
10
18
19
20
21
22
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
HI
MED
LO
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
5
Loading...
+ 11 hidden pages