Haier HSU-09H03-R2 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09H03/R2(DB) HSU-12H03/R2(DB)
Please read this operation manual before using the air conditioner.
No.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inop­erative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum:D.B/W.B Minimum: D.B/W.B
Maximum:D.B/W.B Minimum: D.B
Maximum:D.B Minimum: D.B
Maximum:D.B/W.B Minimum: D.B/W.B
32oC/23oC 18oC/14oC
43oC/26oC 18oC
27oC 15oC
24oC/18oC
-15oC
7. The appliance is not intended to use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not play with the appliance.
9 .The distance between the indoor unit and the floor should be more than 2m.
10.The appliance must be installed on strong enough supporter.
11 .The wiring diagram is attached inside the machine.
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use The instructions are classified into two levels, WARNING and CAUTION according to
the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
Installation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth cable.
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
PROHIBITION PROHIBITION
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
STRICT ENFORCEMENT
Cautions
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
WARNING
Use an exclusive power source with a circuit breaker
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not use power supply cord
extended or connected in halfway
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
Parts and Functions
Indoor unit
Test running switch(manual)
Used only for test running in cooling
Inlet grille
when room temp. is below 16oC. Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Air filter
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Outdoor unit
Power indicator
Lights up when unit starts.
Timer mode indicator
Lights up when Timer operation is selected.
Remote signal receiver
A beeping sound is generated when a signal from remote controller is received.
Operation mode indicator
Lights up during compressor running.
INLET
OUTLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Parts and Functions
Buttons and display of the remote controller.
7. FAN SPEED display
AUTO
LOWHI MEDAUTO
H
4
5
1. SWING button Used to select up or down air sending direction.
2. HOUR button Used to set timer setting.
3. MODE button Used to select operation mode. COOL,DRY, HEAT.
4. TIMER button Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
5. RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal
6.Operation mode display
8. DESIGNATED PERIOD diplay Indicates the period set by the time setting switches.
9. TEMP button
Used to select your desired temperature.
10. CODE display
11. SIGNAL SENDING display
12. LOCK display
13. TEMP display
Remote controller: to display the TEMP. setting.
14.TIMER MODE display
OFF:The air conditioner stops operation after the designed period. ON:The air conditioner starts operation after the designed period.
15. POWER/SOFT display
16. FAN button Used to select fan speed: AUTO, HI,MED,LOW, 17 ON/OFF button Used for unit start and stop.
18. POWER/SOFT button
19. LOCK Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be cancelled and lock condition display disappears.
20. CODE Used to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation.
DRY HEATCOOL
Parts and Functions
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
«Î—°”√Õ¨“ª∆∑≈∆¡ΩΩ⁄ 7#
µÁ≥ÿ,≥§ ±º‰≤ª”√ ±,Œ™ ∑¿÷𬩓π«ÎΩ´µÁ≥ÿ»°
≥ˆ°£ ‘⁄ π”√÷–»Á”ˆ“Ï≥£,«Î Ω´µÁ≥ÿ»°≥ˆ,6∑÷÷”∫Û‘Ÿ
◊∞»Î–¬µÁ≥ÿ°£
∫£∂˚ºØÕ≈«‡µ∫∫£∂˚ ø’µ˜∆˜”–œfi◊‹π´Àæ
«Î—°”√Õ¨“ª∆∑≈∆¡ΩΩ⁄ 7# µÁ≥ÿ,≥§ ±º‰≤ª”√ ±,Œ™ ∑¿÷𬩓π«ÎΩ´µÁ≥ÿ»° ≥ˆ°£ ‘⁄ π”√÷–»Á”ˆ“Ï≥£,«Î Ω´µÁ≥ÿ»°≥ˆ,6∑÷÷”∫Û‘Ÿ ◊∞»Î–¬µÁ≥ÿ°£
∫£∂˚ºØÕ≈«‡µ∫∫£∂˚ ø’µ˜∆˜”–œfi◊‹π´Àæ
Load the battery:
Be sure that the loading is in line with the" + "/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.
«Î—°”√Õ¨“ª∆∑≈∆¡ΩΩ⁄ 7# µÁ≥ÿ,≥§ ±º‰≤ª”√ ±,Œ™ ∑¿÷𬩓π«ÎΩ´µÁ≥ÿ»° ≥ˆ°£ ‘⁄ π”√÷–»Á”ˆ“Ï≥£,«Î Ω´µÁ≥ÿ»°≥ˆ,6∑÷÷”∫Û‘Ÿ ◊∞»Î–¬µÁ≥ÿ°£
∫£∂˚ºØÕ≈«‡µ∫∫£∂˚ ø’µ˜∆˜”–œfi◊‹π´Àæ
Operation
Cool/Dry mode Operation
1. Unit start Link with electric power.
Remote Controller
Press ON/OFF on the remote controller, unit start. The liquid crystal will display the working state of last
time (Except Timer, Power/Soft ).
2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller:
Then select COOL or DRY operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1 C,if kept depressed, it will decrease rapidly
Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
DRY HEATCOOL
LOWHI MEDAUTO
Air conditioner is running under displayed fan speed. When FAN is set to AUTO,the air conditioner
automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
8
Operation
Heat Operation
1. Unit start
Remote Controller
2. Select operation mode
3.Select temp.setting
4. Fan speed selection
Link with electric power. Press ON/OFF on the remote controller, unit start.
The liquid crystal will display the working state of last time (Except Timer, Power/Soft airflow).
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
DRY HEATCOOL
Then select HEAT operation
Press TEMP. button
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1 C,if kept depressed, it will decrease rapidly
Select a desired temperature.
Press FAN button. For each press. fan speed change as follows:
Remote controller:
LOWHI MEDAUTO
Air conditioner is running under displayed fan speed. In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO,the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop Press ON/OFF button, the unit stops.
On cooling only unit, heating mode is not available.
9
Operation
Air Flow Direction Adjustment
Vertical Adjustment
During Cooling, Dry Operation
During Heating Operation
When ON/OFF switch is pressed, the vertical louver will move to the adequate positions for each operation automatically.
Swing of Air Flow
If air flow direction switch is pressed once,
Approx. degrees
Level
10
Approx. degrees
Level
60
the vertical louver will move within the range of figures as right.
Fixing the Flow Direction
If air flow direction switch is pressed again, the vertical louver will be fixed and that position is more memorized. From the next operation the louver will be set at previous position automatically.
Approx. degrees
Approx.
degrees
Level
10
45
Approx.
degrees Approx.
degrees
Level
10
60
NOTICE
When the operation is off, the vertical louver closes the outlet automatically. Don't move the vertical louver by hands. It may make the louver not work properly. In order to move the vertical louver, use remote controller without fail. In case the louver does not work correctly, once stop the operation and turn on again. During cooling or dry operation, the vertical louver should not be downward for a long time. If this is done, dew drops may appear at the outlet.
Horizontal Adjustment
Adjust the horizontal louver by moving the adjustment tabs. If the system is operated with the horizontal louver faced completely to the left or right under high humidity (e.g. during the rainy season), dew drops may appear at the outlet.
Operation
Timer Off Operation
Remote Controller
With this function, the system stops operating after the designated period.
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2.Set the timer mode to "OFF" by pressing the timer mode switch.
3.Time setting Press HOUR button.
Every time the button is pressed, time setting increases 1 h, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 h, if kept depressed, it will decrease rapidly. It can be set from 1 hour to 12 hours
4.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
NOTICE
Once the remote controller set the timer, the period is memorized. From next time operate easily with operation of the ON/OFF switch and the timer mode swith.
After replacing the dry batteries, the designated period is set automatically as follows: OFF: 1 hour, ON: 6 hour. Set the timer again if necessary.
If the power fails, set timer again.
11
Operation
Timer On Operation
Remote Controller
With this function, the system starts operating after the designated period: the system can be set to turn on automatically at the time of awakening or arriving home.
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD.
2.Set the timer mode to "ON" by pressing the timer mode switch.
3.Time setting
Press HOUR button. Every time the button is pressed, time setting increases 1 h, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 h, if kept depressed, it will decrease rapidly. It can be set from 1 hour to 12 hours .
4.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears.
12
Operation
Power/Soft Operation
POWER Operation
When you need rapid heating or cooling, you can use this function.
Remote Controller
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed,display changes as follows:
POWER
Stop the display at
In POWER operation status:
In HEAT mode, fan speed automatically runs in HI mode for 15 min then returns to original status setting.
In COOL mode, fan speed automatically runs in MED mode for 15 min then returns to original status setting.
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
SOFT
BLANK
SOFT Operation
You can use this function when silence is needed for rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
POWER
SOFT
BLANK
Stop the display at In SOFT operation mode, fan speed automatically takes"LOW"
To cancel SOFT operation
Press POWER/SOFT button once ,POWER/SOFT disappears.
Hints: During POWER operation, in rapid HEAT or COOL mode, the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
Operation
Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, it can't operate for dehumidifying or under timing mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the normal operation mode.
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Close doors and windows during operation
Do not block the air inlet or outlet
Use the timer effectively
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the louvers effectively
15
Maintenance
For Smart Use of The Air Conditioner
WARNING
Before maintenance, be sure to turn off the system and the circuit breaker.
Remote Controller
Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth.
Indoor Body
Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping, then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline,benzine,thinner or cleanser may damage the coating of the unit.
Hot water over 40oC(104oF) may cause discoloring or deformation.
Air Filter Cleaning
Open the inlet grille by pulling it upward. Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Air Filter
Once every
two weeks
Close the inlet grille.
Maintenance
To Keep Your Air conditioner in Good Condition after Season
Operate in cooling mode for 2-3 hours.
To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30OC,cooling mode and High speed fan mode for 2-3 hours.
Put off the power supply cord.
Cleaning the body.
Take out the batteries from the wireless remote controller.
Maintenance
Before Setting in High Season
Cleaning the standard air filter.
Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes.
Connecting the earthing cable.
Caution
Incomplete earthing may cause an electric shock.
Do not block the air inlet or outlet.
Plug-in
Caution
After brush away dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of using exclusive circuit breaker,switch on the circuit breaker.
EARTHING
NO WET HAND
Trouble shooting
Before asking for service, check the following first.
Cause or check pointsPhenomenon
Normal Performance inspection
The system does not restart immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Multiple check
Does not work at all.
Poor cooling
Is power plug inserted? Is there a power failure? Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation?
19
Loading...