Haier HSU-09H03-K-F, HSU-12H03-K-F, HSU-12C03K, HSU-12C03-K-F User Manual

0 (0)
Installation Manual of Room Air Conditioner
Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No. Accessory parts
1
2
3
4
5
Remote controller
R-03 dry battery
Mounting plate
Drain hose
4X50
Steel nail, cement
Number of articles
1
2
1
1
6
5.Torque wrench(17mm,22mm,26mm)
7.Flaring tool
8.Knife
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
mc 5nahterom
Optional parts for piping
Mark
A
B
C
D
E
F
G
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
1nahterom
mc0
Attention must be paid to the rising up of drain hose
mc01nahterom
A
6
7
8
10
4X25
Screw
9
Plastic cap
Cover
Cushion
Pipe supporting plate
Drain-elbow
No.0010531057
4
1
4
1
Arrangement of piping directions
Rear left
Below
Rear right
Right
Left
nahterom
c01
m
mc01nahte
r
o
m
C
1
D
E
m
mc06na
ht
ero
m
G
The marks from to in the figure are the parts numbers.
A
The distance between the indoor unit and the floor should be more than 2m.
o
1nahter
mc5
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-09H03/K(F)
HSU-12H03/K(F) HSU-12C03/K(F)
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
Liquid pipe ( )
Gas pipe ( )
For 09k For 12k
6.35mm(1/4")
9.52mm(3/8")
6.35mm(1/4")
12.7mm(1/2")
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
B= 66mm
A=210mm
mm03
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
Indoor side
Wall hole
66mm
(Section of wall hole)
2
G
Piping hole pipe
Outdoor side
Thickness of wall