Haier HSU-09H03-K, HSU-12H03/K User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09H03/K(F) HSU-12H03/K(F)
Contents
PARTS AND FUNCTIONS
OPERATION
CAUTIONS
TROUBLE SHOOTING
1 2-5
6.7 7
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010531056
Parts and Functions
Indoor Unit
1
2
3
5
7
4
1
1
Inlet
2
2
Inlet grille
3
3
Air Purifying Filter (inside)
5
4
Outlet
5
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
6
6
Vertical blade
(adjust left and right air flow)
7
Anion generator
Actual inlet grille may vary from the one shown in the manual according to the product purchased
8
Display board
1
1
Signal receiver hole
iFP display
2
3
HEALTH display
(If the unit which you purchased
has healthy function,follow it. If not,please ignore.)
4
TIMER OFF display
TIMER ON display SLEEP display
3
2
5
4
6
Ambient temp.display
5
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
SMART display
6
COOL display
7
Dry display
8
HEAT display
9
8
7
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
Outdoor Unit
OUTLET
INLET
1
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
14
(inside)
9
Once every two weeks
Remote controller
Outer side of the controller
Operation mode display
4
5
6
8
Display of each function status
SMART button
Used to set SMART operation.
COOL button
Used to set COOL operation.
HEAT button
Used to set HEAT operation.
DRY button
Used to set DRY operation.
ECONOMY button
Used to set ECONOMY operation.
iFP button
Induce the movement of the human body, so as to control the airflow/energy saving functioning.
Inner side of the controller
SWING button
Used to select up or down air sending direction.
HEALTH button
Used to set healthy operation.
HEALTH AIRFLOW button
Used to set the health airflow mode.
POWER / SOFT button
Use to set power/soft function.
LIGHT
button
Control the lightening and extinguishing of the indoor LED display board.
INQUIRE
button
Inquire the external environmental temperature and the operating power of the machine. (e.g. when the panel display “01”, the operating power is 100W; when the panel display 02, the operating power is 200W, and so forth).
RESET button
When the remote controller appears abnormal,use a sharp pointed article to press this button to reset the remote controller normal.
Signal sending end
SMART
SET TEMP.
COOL
ROOM TEMP.
HEAT
FAN
DRY
AUTO AUTO
CTD
FAN SPEED
POWER
SOFT
ECO
iFP
AM PM
SMART ON/OFF
COOL
HEAT
DRY
ECONOMY FAN SPEED
iFP
SMART
SET TEMP.
COOL
AUTO
TIMER ON OFF
FOLLOW
EVADE
ROOM TEMP.
HEAT
FAN DRY
AUTO AUTO
CTD
FAN SPEED
POWER
SOFT
ECO
iFP
AM PM
SMART
CODE button
Used to select CODE A or B with a press, A or B will be displayed on LCD. Please select A without special explanation.
AUTO
TIMER ON OFF
Signal sending display
TEMP display
Remote controller: to display the TEMP. setting.
FAN SPEED display SWING UP/DOWN display Left/right air flow display
TIMER ON display TIMER OFF display CLOCK display
ON/OFF button
Used for unit start and stop.
TEMP. button
Used to select your desired temperature.
FAN SPEED button
Used to select fan speed: LOW,MED, HI, AUTO.
FOOLLOW / EVADE button
Detect the location where the human body is, adjust the air deflector to blow/avoid the body.
NOTE:
This function unavailable on this models
SWING button
Used to select left or right air sending direction.
FRESH button
Used to set fresh operation.
SLEEP button
Used to select sleep mode.
CLOCK button
Used to set correct time.
TIMER ON / OFF button
Used to select TIMER ON, TIMER OFF,TIMER ON-OFF.
HOUR button
Used to set clock and timer setting.
CANCEL/CONFIRM button
Used to confirm timer and clock settings.
LOCK button
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition
Press it once again, lock will be cancelled and lock condition display disappears.
display appears.
Operation
Loading of the battery
1
Remove the battery cover;
2
3
Clock set
SMART
Load the batteries as illustrated. 2 R-03 batteries,resetting key(cylinder); Be sure that the loading is in line with the" + "/"-";
Load the battery,then put on the cover again.
AM PM
Press CLOCK button,
1
"AM" or "PM" flashes.
Press “+” or “-” to set correct time.
2
Each press will increase or decrease 1min. If the
button
is kept pressed,time will change quickly.
SMATR Operation
One key can give you a comfortable room!
SMART
The air conditioning unit can judge the indoor temperature and humidity, and make the adjustment accordingly.
SMART
AM
SMART
Press ON/OFF button, unit starts.
Press SMART button“ ” is displayed on the remote controller and “ ” is displayed on
the display board,
SMART FRESH
SMART Defrost SMART FAN SPEED
SMART FAN HEALTH
SMART DRY
SMART SOFT
SMART
SMART
Under the cooling, heating and dehumidifying mode, press the smart key to enter the smart function. Under the smart running mode, when the air conditioning is running, it will automatically select cooling, heating, dehumidifying or blowing mode as per the setting temperature. When the smart function is running, press the “cooling” “heating” or “dehumidifying” key to switch to the other mode, you will exit from the smart function.
SMART start
SMART
unit will run in SMART mode.
Control temperature
or
SMART stops
COOL,HEAT and DRY Operation
1
Select operation mode.
2
Unit start.
3
Confirm
time.
After time setting is confirmed, press CONFIRM,"AM "and "PM" stop flashing,while clock starts working.
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals,
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation,
please
If there are any display
remove the batteries and
Hint:
Remove the batteries in case unit won't be in usage for a long period.
after taking-out, just need to press reset key
Please change batteries.
reload several minutes later.
Press COOL button“ ” is displayed on the remote controller and “ ” is displayed on
AM
SMART
1.In DR
Y mode, when room temperature becomes lower than temp.setting+2
unit will run intermittently at LOW speed regardless of FAN setting.
Remote controller can memorize each operation status. When starting it next time,
2. just press ON/OFF button and unit will run in previous status.
Cooling only unit do not have displays and functions related with heating.
3.
the display board,
Press HEAT button“ ” is displayed on the remote controller and “ ” is displayed on the display board,
Press DRY button“ ” is displayed on the remote controller and “ ” is displayed on the display board,
unit will run in COOL mode.
unit will run in HEAT mode.
unit will run in DRY mode.
o
C,