Before disposing an old air conditioner that
goes out of use, please make sure it's
inoperative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system
contains refrigerants, which require specialized waste disposal. The valuable materials
contained in an air conditioner can be recycled.
Contact your local waste disposal center for
proper disposal of an old air conditioner and
contact your local authority or your dealer if
you have any question. Please ensure that
the pipework of your air conditioner does not
get damagedprior to being picked up by the
relevant waste disposal center, and contribute
to environmental awareness by insisting on an
appropriate, anti-pollution method of disposal.
All these valuable materials may be taken to
a waste collecting center and used again after
adequate recycling.
Consult your local authorities for the name
and address of the waste materials collecting
centers and waste paper disposal services
nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly,
operation and maintenance of the air
conditioner.
The manufacturer does not accept responsibility for any damages that may arise due
to non-observation of the following
instruction.
Disposal of the packaging of your
new air conditioner
All the packaging materials employed in the
package of your new air conditioner may be
disposed without any danger to the
environment.
The cardboard box may be broken or cut into
smaller pieces and given to a waste paper
disposal service. The wrapping bag made of
polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
Page 3
Cautions
Air Conditioner
Edition:2006/1/18
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air
conditioner before openning inlet grill. Never
unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the outlet.
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.
Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or perforating the air conditioner's tubes
with sharp or pointed items, crushing or
twisting any tubes, or scraping the coatings
off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in
serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditoner.Do not put fingers
or any other things into the inlet/outlet and
swing louver.
Specifications
The refrigerating circuit is leak-proof.
Remark per EMC Directive 89/336/EEC.
To prevent flicker impression during the
start of the compressor(Technical Process)
and the adversely influence caused by
the 2nd harmonies of compressor following
installation conditions do apply:
1.The power connection for air conditioner
has to be done at the main power
distribution.This distribution has to be of a
Iow impedance. Normally the required
impedance is reached at a 32A fusing point.
2.No other equipment has to be connected:
to this power line.
3.For the details installation acceptance
please refer to your contract with the power
supplier, if restrictions do apply for products:
like washing machines,air conditioners or
electrical ovens.
4.For the details of the power of air,
conditioner, please refer to the rating plate
of the product.
5.For any question contact your local dealer.
Do not allow children to play with the air
conditioner.In no case should children be
allowed to sit on the outdoor unit.
Page 4
Air Conditioner
Cautions
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Edition:2006/1/18
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11 .The wiring diagram is attached inside the machine.
Maximum: D.B / W.B
Minimum: D.B / W.B
Maximum: D.B
Minimum: D.B
Maximum: D.B
Minimum: D.B
Maximum: D.B / W.B
Minimum: D.B / W.B
32oC/23oC
18oC/14oC
43oC/26oC
18oC
27oC
15oC
24oC/18oC
-7oC/-8oC
Page 5
Air Conditioner
Parts and Functions
Indoor unit
Outlet
Edition:2006/1/18
Inlet
Inlet grille
UV light degerming
device (inside)
Anion generator
(inside)
Horizontal louver(inside)
(adjust left and right air flow)
Outdoor unit
Air Purifying Filter
(inside)
Air filter(inside)
POWERTIMER HEALTHRUN
display board
Vertical flap
(adjust up and down air flow.
Don't adjust it manually)
Power plug
OUTLET
INLET
HSU-09CU13
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Page 6
Air Conditioner
Parts and Functions
POWER TIMERHEALTHRUN
19
Edition:2006/1/18
POWER/SOFT
28
30
1.CODE
Used to select CODE A or B with a press,A or B
will be displayed on LCD.
Please select A without special explanation.
2.RESET
When the remote controller appears abnormal,
use a sharp pointed article to press this button
to reset the remote controller normal.
3.LIGHT button
Control the lightening and extinguishing of
the indoor LED display board.
4. TIMER button
Used to select TIMER ON, TIMER OFF,
TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
6. HEALTH button
Used to set healthy operation.
7. MODE button
AUTO COOL DRY FAN
8. HOUR button
Used to set clock and timer setting.
9. SWING button
Used to select up or down air sending direction.
10. ON/OFF button
Used for unit start and stop.
32
31
34
33
16
11. TIMER ON display
12. FAN SPEED display
LOWHI
MEDAUTO
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
17. Operation mode display
Operation mode
Remote controller
AUTOFANCOOL DRY
18.Singal sending display
19. POWER/SOFT display
20. Left/right air flow display
21. TEMP display
Remote controller: to display the TEMP. setting.
22. TIMER OFF display
23. CLOCK display
24. TEMP button
Used to select your desired temperature.
25. FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
26. HEALTH AIRFLOW button
Used to set the health airflow mode.
27. SLEEP button
Used to select sleep mode.
28. SET button
Used to confirm timer and clock settings.
29. POWER/SOFT button
Use to set power/soft function.
30. LOCK
Used to lock buttons and LCD display. If pressed, the
other buttons will be disabled and the lock condition
display appears. Press it once again, lock will be
canceled and lock condition display disappears.
31. Remote signal receiver
32. Operation mode indicator
Lights up during compressor running.
33. Timer mode indicator
Lights up when Timer operation is selected.
34. Power indicator
Lights up when unit starts.
NOTE: The following functions and related displays are not available: 20
Page 7
Air Conditioner
Edition:2006/1/18
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in
remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease
1 min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing,
while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within
7m without any obstacle as well.
Don't throw or knock the remoter controller.
HEALTH
POWER/SOFT
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or
wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving
the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right
2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover
as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-".
request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up.
Please change batteries.
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display
after taking-out, just need to press reset key.
Page 8
Operation
HEALTH operation
Remote controller
1.Unit start
Press ON/OFF on the remote controller, unit starts.
Health function includes health anion function, UV light
degerming function.
2.Health anion function
Press HEALTH button. For each press, is displayed.
Air conditioner starts health anion function operation.
For twice press, disappears,the operation stops.
Air Conditioner
Edition:2006/1/18
POWER/SOFT
When indoor fan motor is running, it has healthy
process function. (It's available under any mode)
When the fan in the indoor unit does not work, the health lamp
lights up, but the anion generator does not release anion.
BRIEF INTRODUCTION TO HEALTH ANION FUCTION
The anion generator in the air conditioner can generate a lot of
anion effectively balance the quantity of position and anion in the
air and also to kill bacteria and speed up the dust sediment in
the room and finally clean the air in the room.
About UV light degerming function
UV light emitted by the UV light device of the indoor unit catalytically
activates the nano TiO2 on the multi-lights touching intermediary,
and the degerming effect is highly efficient and lasting.
Note: when the function is running, don't open the inlet grille.
Page 9
Operation
Auto Operation
Air Conditioner
Edition:2006/1/18
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTOCOOLDRYFAN
Then
Select Auto operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
LOW
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
MED
HI
5.Unit stop
Press ON/OFF button, the unit stops.
About Auto Operation
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.
AUTO
Page 10
Operation
Cool Operation
Air Conditioner
Edition:2006/1/18
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTOCOOLDRYFAN
Then Select COOL operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
Remote controller:
LOW
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
MED
HI
5.Unit stop
Press ON/OFF button, the unit stops.
AUTO
Page 11
Operation
Dry Operation
Air Conditioner
Edition:2006/1/18
Remote controller
POWER/SOFT
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTOCOOLDRYFAN
Then Select DRY operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
COOL operation starts when room
temp.is higher than temp.setting.
Temp.setting+2oC
Temp.setting
On reaching temp.setting +2oC
unit will run in mild DRY mode.
Ultra-low air flow
LOW
MED
HI
Air conditioner is running under displayed fan speed.
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
5.Unit stop
Press ON/OFF button, the unit stops.
AUTO
Page 12
Operation
Fan Operation
Remote controller
Air Conditioner
Edition:2006/1/18
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
POWER/SOFT
AUTOCOOLDRYFAN
Then Select FAN operation
3.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
LOW
MED
HI
4.Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.
Page 13
Air Conditioner
Operation
Air Flow Direction Adjustment
1.Status display of air sending
Vertical flap
Pos.1
Pos.2
Pos.3
Edition:2006/1/18
Pos.4
POWER/SOFT
Pos.5
Pos.6
(Auto swing)
2.Up and down air flow direction
For each press of button, air flow direction on remote controller displays
as follows according to different operation modes:
COOL/DRY/FAN
remote controller:
:
HEAT:
remote controller:
AUTO:
remote controller:
The vertical flap will swing according to the above positions
Pos.1Pos.2Pos.3Pos.4Pos.6
Pos.5Pos.4Pos.3Pos.2Pos.1Pos.6
Pos.1Pos.2Pos.3Pos.4Pos.5Pos.6
Note:When restart after remote turning off, the remote controller will automatically
memorize the previous set swing position.
Page 14
Operation
Air Conditioner
Edition:2006/1/18
Sleep Operation
Before going to bed, you can simply press the
SLEEP button and unit will operate in SLEEP
mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts, set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
become 1OC higher than temp. setting. After
another 1 hours, temp. rises by 1OC further.
The unit will run for further 6 hours then stops.
Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
Remote Controller
POWER/SOFT
SLEEP operation startsSLEEP operation stops
Approx.6hrs
Rises 1OC
1 hr
Rises 1OC
1 hr
Temp.setting
In HEAT mode
2.
In COOL, DRY mode
Unit stop
1 hours after SLEEP mode starts, temp
will become 2 OC lower than temp.
setting. After another 1 hours, temp
decrease by 2 OC further. After more
another 3 hours, temp. rises by 1OC
further. The unit will run for further 3
hours then stops. Temp. is lower than
temp. setting so that room temperature
won't be too high for your sleep.
SLEEP
operation starts
In AUTO mode
3.
Temp.setting
1 hr
1 hr
Decreases 2OC
Decreases 2OC
3 hrs
In HEAT mode
Unit stop
3 hrs
Rises 1OC
SLEEP
operation stops
The unit operates in corresponding sleep
mode adapted to the automatically selected
operation mode.
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before
setting for the sleep, set for lowing the wind
speed after sleeping.
If it is low wind, no change.
Note
When TIMER function is set, the sleeping function
can't be set up .After the sleeping function is set up,
if user resets TIMER function, the sleeping function
will be cancelled; the machine will be in the state of
timing-on.
Page 15
Operation
Timer On/Off Operation
Set clock correctly before starting TIMER operation.
Remote Controller
1. After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2. Timer mode selection
Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
Air Conditioner
Edition:2006/1/18
BLANK
POWER/SOFT
TIMER ON TIMER OFFTIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or
TIMER OFF). " "or " "will flash.
3.Time setting
Press HOUR button.
Every time the button is pressed, time setting
increases 1 min, if kept depressed, it will increase
rapidly.
Every time the button is pressed, time setting
decreases 1 min, if kept depressed, it will decrease
rapidly.
It can be adjusted within 24 hours.
4.Confirming your setting
After setting correct time, press SET button to confirm
" "or" "on the remote controller stops flashing.
Time displayed: Unit starts or stops at x hour x min.
(TIMER ON or TIMER OFF).
5.Cancel TIMER mode
Just press TIMER button several times until TIMER
mode disappears.
Hints:
After replacing batteries or a power failure happens, time setting should be reset.
Remote controller possesses memory function, when use TIMER mode next time,
just press SET button after mode selecting if time setting is the same as previous one.
Page 16
Operation
Timer On-Off Operation
Set clock correctly before starting TIMER operation.
Remote Controller
1. After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2. Timer mode selection
Press TIMER button to change TIMER mode. Every time
the button is pressed, display changes as follows:
Remote controller:
Air Conditioner
Edition:2006/1/18
BLANK
POWER/SOFT
TIMER ON TIMER OFFTIMER ON-OFF
Then select your desired TIMER mode (TIMER ON - OFF).
" "will flash.
3.Time setting
Press HOUR button.
Every time the button is pressed, time setting increases
1 min, if kept depressed, it will increase rapidly.
Every time the button is pressed, time setting decreases
1 min, if kept depressed, it will decrease rapidly.
It can be adjusted within 24 hours.
4.Timer confirming for TIMER ON
After setting correct time, press TIMER button to confirm
" " on the remote controller stops flashing.
" " starts flashing.
Time displayed: Unit starts or stops at x hour x min.
5.Time setting for TIMER OFF
Just press HOUR button ,follow the same procedure in
"Time setting for TIMER ON"
6.Time confirming for TIMER OFF
After time setting,press SET button to confirm.
" " on the remote controller stops blinking.
Time displayed:Unit stops at x hour x min.
To cancel TIMER mode
Just press TIMER button several times until TIMER
de disappears.
According to the Time setting sequence of TIMER ON
or TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
Page 17
Air Conditioner
Operation
POWER/SOFT Operation
POWER Operation
When you need rapid heating or cooling, you can use this function.
Remote controller
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
Stop the display at
In POWER operation status:
In HEAT or COOL mode, compressor runs in high frequency
for 15 min then returns to original status setting.
You can use this function when silence is needed for rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
POWER
Stop the display at
In SOFT operation mode, fan speed automatically takes"ultra-low"
SOFT
To cancel SOFT operation
Press POWER/SOFT button again ,POWER/SOFT disappears.
Hints:
During POWER operation, in rapid HEAT or COOL mode, the room
will show inhomogeneous temperature distribution.
Long period SOFT operation will cause effect of not too cool
or not too warm.
BLANK
Page 18
Operation
Health airflow Operation
Air Conditioner
Edition:2006/1/18
Remote controller
POWER/SOFT
1.Press ON/OFF to starting
The liquid crystal will display the working state of last time
(Except timer, sleeping, power/soft and health airflow).
Setting the comfort work conditions.
2.The setting of health airflow function
1).Press the button of health airflow, appears on the
display. The nether inlet and outlet grills of the air conditioner are closed and the airflow is blown horizontally from
the above inlet and outlet grills. Avoid the strong airflow
blows direct to the body.
2).Press the button of health airflow again, appears on
the display. The above inlet and outlet grills of the air conditioner are closed and the airflow is blown vertically from the
nether inlet and outlet grills. Avoid the strong airflow blows
direct to the body.
3.The cancel of the health airflow function
Press the button of health airflow again, both the inlet and
outlet grills of the air conditioner are opened, and the unit
goes on working under the condition before the setting of
health airflow function.
After stopping, the outlet grille will close automatically.
Notice: Cannot pull direct the outlet grille by hand. Otherwise,
the grille will run incorrectly. If the grille is not run correctly,
stop for a minute and then start, adjusting by remote controller.
Note:
1 .After setting the health airflow function, the position of inlet
and outlet grills is fixed.
2.In heating, it is better to select the mode.
3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long time
under the high air humidity, a phenomenon falling drips of
water occurs at the outlet grille .
5.Select the appropriate fan direction according to the actual
conditions.
Page 19
Air Conditioner
Operation
Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which means
the start of this operation.
In this operation, the system automatically selects
the operation modes, cooling or heating, according
to the room temperature.
Temperature
Operation
mode
Designated
temperature
Timer
mode
Air flow
emergency operation switch
Edition:2006/1/18
POWERTIMER HEALTHRUN
ABOVE 23OC
BELOW 23OC
COOLING
HEATING
26OC
23OC
NO
NO
AUTOMATIC
AUTOMATIC
It is not possible to operate in dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16OC, do not use it in the normal
operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling operation
test operation switch
starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.
POWERTIMER HEALTHRUN
When the remote controller is manipulated, it gets the system back to the
normal operation mode.
Loading...