Haier HSU 07HD03R2 Schematic

Air Conditioner

REVISION 0
HSU-09HD03/R2
CAUTION
READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE .
SERVICE MANUAL
MODEL: HSU-07HD03/R2
Air Conditioners
MODEL: HSU-07HD03/R2MODEL: HSU-07HD03/R2
Edition:2006/1/10
RESPONSIBILITY FOR PROPERTY
DAMAGE OR PERSONAL INJURY
PROCEDURES DONE BY ONE
THIS MANUAL IS USED BY
TECHNICIANS ONLY. HAIER
DOES NOT ASSUME ANY
FOR IMPROPER SERVICE
UNQUALIFIED PERSON.
Air Conditioner



Edition:2006/1/10Air Conditioner
Edition:2006/1/10Air Conditioner
Edition:2006/1/10
IMPORTANT INFORMATION
MODEL: HSU-07HD03/R2
ƽҏFeatures
ƽҏComfortable: wide-angle airflow
ƽhealth air purifying
ƽquiet operation
ƽҏsuper energy efficient
ƽMain Specification
ƽCooling CapacityΚ 2250W
ƽRated Power/Current(cooling)Κ 700W/3.2A
ƽEER: 3.21
ƽHeating CapacityΚ 2250W
ƽRated Power/Current(heating): 620W/2.8A
ƽCOP: 3.63
3
ƽAir Volume(Indoor): 400m
ƽPower: 1PH 220-230V~ 50 Hz
/h
Air Conditioner



Edition:2006/1/10Air Conditioner
Edition:2006/1/10Air Conditioner
Edition:2006/1/10
IMPORTANT INFORMATION
MODEL: HSU-09HD03/R2
ƽҏFeatures
ƽҏComfortable: wide-angle airflow
ƽhealth air purifying
ƽquiet operation
ƽҏsuper energy efficient
ƽMain Specification
ƽCooling CapacityΚ 2650W
ƽRated Power/Current(cooling)Κ 820W/3.7A
ƽEER: 3.23
ƽHeating CapacityΚ 2900W
ƽRated Power/Current(heating): 800W/3.6A
ƽCOP: 3.63
3
ƽAir Volume(Indoor): 450m
ƽPower: 1PH 220-230V~ 50 Hz
/h
Air Conditioner

Edition:2006/1/10
Safety Information
General Information
This Service Manual describes the operation,disassembly,troubleshooting,and repair of Haier Room Air
Conditioners,etc. It is intended for use by authorized servicers who troubleshoot and repair these units.
NOTE:It is assumed that users of this manual are familiar with the use of tools and equipment used to
troubleshoot and repair electrical,mechanical,and refrigeration systems;and understand the terminology
used to describe and discuss them.
Haier urges you read and follow all safety precautions and warnings contained in this manual. Failure
to comply with safety information may result in severe personal injury or death.
Related Publications
This is a base service manual,covering a range of similar models.It is intended to be used in
conjunction with the Parts Manual and Technical Sheet covering specific model being serviced.
General Precautions and Warnings
To avoid risk of personal injury or death due to electrical shock,disconnect electrical power to unit
before attempting to service the unit.
WARNING
WARNING
To avoid risk of personal injury or death due to electrical shock,DO NOT,under any circumstances,alter
the grounding plug .Air conditioner must be grounded at all times.Do not remove warning tag from power
cord.If a two-prong (non-grounding) wall receptacle is encountered,contact a qualified electrician and
have the receptacle replaced with a properly grounder wall receptacle in accordance with the National
Electrical Code.
To avoid risk of personal injury or death due to electrical shock,grounding wires and wires colored like
groundi ng wires are NOT to be used as current carrying conductors.The standar d accepted color c oding
for ground wires is green or green with a yellow stripe.Electrical components such as the compressor
and fan motor are grounded through an individual wire attached to the electrical component and to
another part of the air conditioner.Groundi ng wires should not to be removed from individual components
while servicing,unless the component is to be removed and replaced.It is extremely important to replace
all removed grounding wires before completing service.
WARNING
WARNING
To avoid risk of heat exposure,which may cause death or severe illness,air conditioner must be
monitored when malfunctions or shuts down.
Air Conditioner Edition:2006/1/10C
CONTENTS
1.SPECIFICATION ...............................................................................1
2.OPERATION ......................................................................................
3.ELECTRICAL CONCTROLL..................................................
........
19
4.TROUBLE SHOOTION ...............................................................26
5.INSTALLATION ...............................................................................
6.CIRCUIT AND WIRING DIAGRAM .................................................
....28
37
4
Air Conditioner

Edition:2006/1/10
SPECIFICATION
1
Air Conditioner Edition:2006/1/10
Model
Cooling
Heating
Indoor
Velocity
Outdoor
Velocity
HSU-07HD03/R2
Cooling Capacity
Rated Power/Current
Max Power/Current
EER
Heating Capacity
Rated Power/Current
Max Power/Current 990W/5. 0A
COP 3. 63
H
M
L
H
1000 r/min
860 r/min
2250 W
700 W/3. 2A
1050W/5. 4A
3. 21
2250 W
620 W/2. 8A
1150 r/min
110
Brand Mark
Frequency Range
Power
Refrigerant
Compressor
1PH
Type/Net Charge
haier
50Hz
230V~ 50 Hz
R410A 480g
RECHI/39A173A
manufacturer/Type
Compressor
Oil charge
Operating temp.
ange
0
r/min
r
Height of rising
radiator slice
Indoor Weight
Indoor 1.30 mm
Outdoor
Net
Gross
270 CC
-7OC-43OC
1.37 mm
7.2kg
10. 2 kg
Air
Volume
(High)
Class of electric Shock Protection
Class of Water Proof IP 24 Outdoor Packaging dimension(L×W×H) 818 ×359 ×515 mm
Moisture Removal
Remote
Controller Refer. No.
Climate Type edislooctaerusserp.xaM1T
Area available for clooling/heating
Max.running
temperature(cooling):
Indoor
1.0×10-3m3/h
Model
15-23 m
Dry/Wet ball(indoor) 32 /223 Dry/Wet ball(indoor) / --
Dry/Wet ball(outdoor) 43 / 26
m3/h
400
H
0010402640
Outdoor Weight
Indoor Dimension(L×W×H) 795 ×265 ×182 mm
Indoor Packaging Dimension(L×W×H) 865 x272 x330 mm
Outdoor Dimension (L×W×H)
Refrigerant
Pipe
2
Max.running
temperature(heating):
liquid /Gas pipe Diametre
standard Lenth
Max Lenth 15 m
Net
Gross
4m
edismrawtaerusserp.xaM
Dry/Wet ball(outdoor):24℃/18℃
27kg
32kg
700 ×250 ×430 mm
6.35/9.52 mm
4.15 MPa
4.15 MPa
27
2
Model
HSU-
09HD03/R2
Cooling Capacity
2650 W
Air Conditioner Edition:2006/1/10
Brand Mark
Frequency Range
haier
50Hz
Cooling
Heating
Indoor
Velocity
Outdoor
Velocity
Rated Power/Current
Max Power/Current
EER
Heating Capacity
Rated Power/Current
Max Power/Current
COP
H
M
L
H
820 W/3. 7A
1300W/6. 0A
3. 23
2900 W
800 W/3. 6A
1300W/6. 0A
3. 62
920 r/min
1200 r/min
0
105
980
r/min
r/min
Power
Compressor
manufacturer/Type
Compressor
Oil charge
Refrigerant
Operating temp. range
Height of rising
radiator slice
Indoor Weight
1PH 230V~ 50 Hz
HITACH/ASG102CV-B7AT
330CC
Type/Net Charge
Indoor
Outdoor
Net
Gross
R410A 680g
-7OC-43OC
mm
1.30
1.37
7. 2kg
10. 2kg
mm
Air
Volume
(High)
Area available for clooling/heating
Class of electric Shock Protection Outdoor Dimension (L×W×H)
Class of Water Proof IP 24 Outdoor Packaging dimension(L×W×H) 818 ×359 ×515 mm
Moisture Removal
Controller Refer. No.
Climate Type
Max.running temperature(cooling):
Indoor
Model
edislooctaerusserp.xaM
Dry/Wet ball(indoor) 32 /223
Dry/Wet ball(outdoor) 43 / 26
450 m3/h
2
m
15-23
1.2×10-3m3/h
H
0010413791
4.15MPa
1T
Outdoor Weight
Indoor Dimension(L×W×H) 795 ×265 ×182 mm
Indoor Packaging Dimension(L×W×H) 865 x272 x330 mm
Refrigerant
Pipe
Max.running temperature(heating):
liquid /Gas pipe Diametre
standard LenthRemote
Max Lenth 15 m
Net
Gross
edismrawtaerusserp.xaM 4.1 5 MPa
Dry/Wet ball(indoor) / --
Dry/Wet ball(outdoor):24℃/18℃
29kg
34kg
700 ×250 ×430 mm
6.35/9.52 mm
4
m
27
3
Air Conditioner

Edition:2006/1/10
OPERATION
4
Air Conditioner

Cautions
The machine is adaptive in following situation
I. Applicable ambient temperature range:
Edition:2006/1/10
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11.The wiring diagram is attached inside the machine.
Maximum: D.B / W.B 32oC/23oC Minimum: D.B / W.B
Maximum: D.B Minimum: D.B Maximum: D.B
Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
18oC/14oC 43oC/26oC
18oC 27oC
15oC 24oC/18oC
-7oC/-8oC
5
Air Conditioner

Parts and Functions
Edition:2006/1/10
Indoor Unit
Inlet grille
Air filter
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
HSU-07HC03/R2 HSU-07HE03/R2 HSU-09HC03/R2 HSU-09HE03/R2 HSU-12HE03/R2 HSU-12HC03/R2 HSU-14HB03/R2 HSU-18HB03/R2
Power indicator
Lights up when unit starts.
Timer mode indicator
Lights up when Timer operation is selected.
Test running switch(manual)
Used only for test running in cooling when room temp. is below 16oC. Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Remote signal receiver
A beeping sound is generated when a signal from remote controller is received.
Operation mode indicator
Lights up during compressor running.
HSU-09HD03/R2 HSU-12HD03/R2
HSU-07HD03/R2
HSU-22HB03/R2 HSU-22HC03/R2 HSU-22HD03/R2
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Outdoor Unit
HSU-07HC03/R2 HSU-07HE03/R2 HSU-07HD03/R2
HSU-18HB03/R2
HSU-09HE03/R2 HSU-12HE03/R2 HSU-09HD03/R2 HSU-12HD03/R2HSU-09HC03/R2
HSU-12HC03/R2 HSU-14HB03/R2
HSU-22HD03/R2 HSU-22HC03/R2 HSU-22HB03/R2
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
6
Air Conditioner

Parts and Functions
Edition:2006/1/10
Operation
1
2 3
4
11
12
13 14
15
16
17
Clock set
ON/OFF
MODE SET
FAN
SWING
SLEEP
LOCK RESET
Buttons and display of the remote controller.
1. Mode display AUTO
COOL DRY
HEAT
5 6
A U T O
ON OFF
7
8
9
TEMP
TIMER
CLOCK
10
18 19
20
21
22
FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to
normal condition.
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
LO MED HIAUTO
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
7
Air Conditioner

Parts and Functions
Edition:2006/1/10
Operation
Buttons and display of the remote controller.
If the unit which you purchased has healthy function, Remote controller should
like the following figure:
1
ON
2 3
A U T O
OFF
4
ON/OFF TEMP
11
MODE SET
12
13 14
15
16
17
FAN TIMER
SWING CLOCK
SLEEP
HEALTH
LOCK RESET
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
NOTE: Cooling only unit do not have displays and functions related with heating
5 6
7
8
9
10
18 19
20
21
22
1. Mode display AUTO
COOL
DRY
HEAT
FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to normal condition.
23. HEALTH
Used to set healthy operation
AUTO
MED
LO
HI
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
8
Air Conditioner

Operation
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Edition:2006/1/10
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
Load the battery:
Be sure that the loading is in line with the" + "/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.
9