REFRIGERATOR
Service Manual
Models:
HRF- 329AA
HRF- 349AA
HRF- 369AA
Features
l A energy
l Automatic controlling temperature
l Three-cooling system
l Bright VFD display
Haier Group
Serial number: ER03SM0415-01
0
Version number: 00.00
Edition: 2003-04-15
CONTENT
CONTENT
1. Content………………………………………………………… 1
2. Product code illumination and Series Introduction…… 2
3. Specifications……………………….……..…………………. 3
4. Safety precautions……………………………………….….. 4
5. Parts and Functions…………………………………………. 7
6. Function Schedule……………………………......…….…… 8
7. System Flow Chart……………..………………………...…. 9
8. Program Diagram…………………………..………………. 10
9. Maintenance Service and Trouble Shooting…….…..... 11
1
Product code illumination and Series Introduction
Product code illumination and Series Introduction
H R F — 369 AA
series
Gross capacity (according to
export country standard)
Freezer
Refrigerator
Haier product
2
Specifications
Specifications
Models
Net capacity (L) 239 259 289
Color Silver Silver Silver
Power Supply (V/Hz) 220-240~/50 220-240~/50 220-240~/50
Rated Input Power (W)
Power Consumption
(kW.·h/24h)
HRF-329AA HRF-349AA HRF-369AA
130 130 130
0.62 0.65 0.68
Net Weight (kg)
Gross Weight (kg)
Unit Dimension
(D*W*H) (mm)
Packing Dimension
(D*W*H) (mm)
Container Quantity
40’(PCS)
Container Quantity
40’HC(PCS)
72 74 86
96 96 97
660*600*1652 660*600*1672 660*600*1872
833*740*1719 833*740*1719 833*740*1800
42 42 42
42 42 42
3
Function Schedule
Function Schedule
1. Three cooling system
There are three separate cooling parts in the refrigerator — refrigerator、
freezer and soft freezer.seperately
2. Automatic temperature control
Automatic temperature control under varied ambient temperature
conditions for an optimized cooling achievement
3. Application of inverter technology
The advanced inverter technology is applied for integration of noise
reduction and super freezing. Working frequency of the compressor is
automatically adjusted with the variation of ambient temperature.
Unique inverter operation: The refrigerator can be set automatically for
low speed and low noise operation at night.
4. Energy-efficiency
Thick heat insulation is used to minimize temperature gain and to
optimize the cooling system for the most efficient cooling result.
5. VFD display
Application of VFD technology for display of the refrigerator operation
status and temperatures in refrigerator、freezer and soft freezer.
6. Over temp warning
The warning function is activated when freezer temperature exceeds the
set temperature value.
7. Crisper with adjustable moisture
Moisture in the crisper can be adjusted for satisfaction of vegetables and
fruits storage
8
System Flow Chart
System Flow Chart
1 Schematic diagram of System Flow Chart
1 Compressor
2 Hot Tube
3 Condenser
4 Dry Filter
5 Solenoid Valve 1
6 Solenoid Valve 2
6 Evaporator for Soft Freezer
Compartment
7 Evaporator for Refrigerator
Compartment
8 Evaporator for Freezer
Compartment
2 Brief Description of System Flow Chart
The refrigerating system of direct cooling three-system refrigerator
belongs to the category of three circulating system. It is formed by adding
another 3-way solenoid valve and a capillary to a double-system. We can
control the two valves to make refrigerant go through different lines.For
example, 1->2->3->4->5->6->7->9 、 1->2->3->4->5->6->8->9 or
1->2->3->4->5->9.
When the refrigerator is just powered on, the refrigerant flows through
the adjust temperature compartment evaporators and freezer
compartment evaporators. After the adjust temperature compartment
temperature has reached the required value, the solenoid valve is
energized, thus cause the refrigerant to flow through the Refrigerator
Compartment evaporators、freezer compartment evaporators or soft freezer
compartment evaporators.
9