Haier HPU-18H03, HPU-18C03, HPU-24C03, HPU-24H03 Operation Manual

PACKAGED UNIT
OPERATION MANUAL
Please read this operation manual
before using the air conditioner
.
0010519818
HPU-18C03/E1 HPU-24C03/E1 HPU-18H03/E1 HPU-24H03/E1
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of
child
entrapment.
It must be noticed that air conditioner system contains refrigerants,which require specialized waste disposal. The valuable materials contained in an air conditioner
can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you haveany question. Please ensure that the pipework of your air conditioner does not get
damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in
the
package of your new air conditioner may
be disposed without any danger to the environment.
The cardboard box may be broken or cut
into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
All these valuable materials may be taken to
a waste collecting center and used again
after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be
put into operation. In case
of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit byyourself.
For the purpose of the safety,the air conditioner
must be properly grounded in accordance
with specifications.
Always remember to unplug the air
conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out byqualified electricians. Inadequate repairs may result in
amajor source of danger for
the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes
with sharp or pointed items
, crushing or
twisting any tubes
, or scraping the coatings
off the surfaces. If the refrigerant spurts out and gets into eyes
, it may result in
serious eyeinjuries.
1
Cautions
Do not obstruct or cover the ventilation grille of the air conditioner. Donotput fingers or any other things into the inlet/outlet and swing louver.
Do not allow
children to playwith the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken,please change it with the type of T. 3.15A/ 250V.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not playwith the applience.
9. A breaker should be used in the circuits,
which should be all
-pole cutoff and the
distance between its two contacts should be not at least 3mm .
10.Please employ the proper power plug,
which fit into the
power supply cord.
11.The power plug must haveacquired the
local attestation.
The machine is adaptive in following situation
Cooling
Indoor
Outdoor
Maximum: D.B/W.B 32°C
/ 23°C
Minimum: D.B/W.B 18°C / 14°C
Maximum: D.B/W
.B 43°C / 26°C
Minimum: D.B 18°C
Maximum
: D.B 27°C
Minimum:
Minimum:
D.B 15°C
Maximum: D.B/W
.B 24°C / 18°C
D.B/W.B-C/-C
2
Indoor
Outdoor
Heating
Cautions
Please read the following SafetyInstructions carefully prior to use.
The instructions are classified into twolevels, WARNING and CAUTION according to the
seriousness of possible risks and damages as follows. Compliance to the instructions are
strictly required for safety use.
Safety Instruction
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner byyourself because improper worksmay cause electric shock, fire,water leakage.
CAUTION
Installation in an inadequate place may cause accidents. Do not install in the following place.
Connect the earth
cable.
PROHIBITION PROHIBITION
STRICT
ENFORCEMENT
Do not install in the
place where there is any possibilit y of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
Use fuse with specified capacity. Replacement with steel or copper wires are absolutely prohibited.
Grounding wire should not be connected to
that of gas pipeline,water pipeline,lighting arrester or telephone.
FUSE
STEEL WIRE
COPPE
RWIRE
3
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Connect power supply cord to the outlet completely.
After installed, the unit shall be tested for electric leakage.
Take
care not to damage the
power supply cord.
Do not use power supply cord in a bundle.
Donotusepower supply cord extended or connected in halfway.
Do not insert objects into the air inlet or outlet.
Do not try to repair or reconstruct byyourself.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
OFF
STRICT
ENFORCEMENT
STRICT
ENFORCEMENT
Use an exclusivepower source with a circuit breaker.
CAUTION
Do not use for the purpose of
storage of food, art work, precise equipment,
breeding , or cultivation.
Take fresh air occasionally especiallywhen gas appliance is running at the same time.
Do not operate
the switch with wet
hand.
Do not pour water onto the unit for cleaning.
Check good condition of the installation stand.
Do not install
the unit near a fireplace
or other heating apparatus.
Do not place animals or plants in the direct path of the air flow.
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
PROHIBITION
PROHIBITIONPROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
STRICT
ENFORCEMENT
Cautions
WARNING
Use of Air Conditioner
Do not channel the air flow directly at people, especially at infants or the aged.
Do not start or stop the operation by disconnecting
the power supply
cord and so on.
PROHIBITION
4
Parts and Functions
Outdoor unit
Indoor unit
1.OUTLET
2.CONTROL PANEL
4.INLET
3.INLET GRILLE
2.INLET 4.DRAIN HOSE
1.OUTLET 3.CONNECTING PIPING AND ELECTRICA
L WIRING
5
HPU-18C03/E1 HPU-18H03/E1
HPU-24C03/E1 HPU-24H03/E1
Operation mode
AUTO FANCOOLDRY
Remote controller
Display board
18.Singal sending display
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
1. RESET
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
3. TIMER button
Used to set correct time.
4. CLOCK button
Used to select sleep mode.
25. . SLEEP button
6. MODE button
Used to set clock and timer setting.
7. HOUR button
Used to set healthy operation.
5. HEALTH button
Used for unit start and stop.
9. ON/OFF button
10. TIMER ON display
11. FAN SPEED display
12. LOCK displa
y
13. SWING UP/DOWN display
14. SLEEP display
15. HEALTH display
16. E.HEAT display
Used to select your desired temperature.
17. Operation mode display
19. Left/right air flow display
Remote controller: to display the TEMP. setting.
20. TEMP display
21. TIMER OFF display
23. TEMP button
Used to select fan speed: LOW,MED, HI, AUTO.
24. FAN button
8. SWING UP/DOWN button
Used to select up or down air sending direction.
Used to confir
m timer and clock settings.
26. SET button
Used to loc
k b
uttons and LED displa
y. If pressed, the
other b
uttons will be disabled and the loc
k condition
display appears
. Press it once again, lock will be
canceled and lock condition display disappears.
28.
LOCK
22. TIMER display
Remote controller
LOW HI
MED AUTO
19
2. LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
6
20
15
17
28
14
E.HEAT
HEAT
AUTO COOLDRY FAN
HEAT
28
Used to operate electricity
heat
function.
27.
E.HEAT button
B
A
Control panel: See p17
NOTE:(1) The following functions and related displays are not available:
(2) Cooling only unit do not have functions and displays related with heating
.
5
(3)The air conditioner you bought, may not include the E.Heat function, is subject to the actual product.
Parts and Functions
17.Singal sending display
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
1. RESET
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
3. TIMER button
Used to set correct time.
4. CLOCK button
Used to select sleep mode.
24. . SLEEP button
6. MODE button
Used to set clock and timer setting.
7. HOUR button
Used to set healthy operation.
5. HEALTH button
Used for unit start and stop.
9. ON/OFF button
10. TIMER ON display
11. FAN SPEED display
12. LOCK displa
y
13. SWING UP/DOWN display
14. SLEEP display
15. HEALTH display
Used to select your desired temperature.
16. Operation mode display
18. Left/right air flow display
Remote controller: to display the TEMP. setting.
19. TEMP display
20. TIMER OFF display
22. TEMP button
Used to select fan speed: LOW,MED, HI, AUTO.
23. FAN button
8. SWING UP/DOWN button
Used to select up or down air sending direction.
Used to confir
m timer and clock settings.
25. SET button
Used to lock buttons and LED display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
26. LOCK
21. TIMER display
Remote controller
Control panel: See p17
LOW HI
MED AUTO
19
2. LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
7
19
15
16
26
14
Operation mode
AUTO FANCOOLDRY
Remote controller
Display board
AUTO COOLDRY FAN
B
A
NOTE:(1) The following functions and related displays are not available:
(2) Cooling only unit do not have functions and displays related with heating
.
5
Parts and Functions
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
Remote controller's operation
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.
1. Press CLOCK button,"AM" or "PM" flashes.
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hint:
8
E.HEAT