Please read this operation manual before using the air conditioner
No.0010562446
Page 2
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that
goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system
contains refrigerants, which require speciali-zed
waste disposal. The valuable materials contained
in an air conditioner can be recycled
Contact your local waste disposal center for
proper disposal of an old air conditioner and
contact your local authority or your dealer if
you have any question. Please ensure that
the pipework of your air conditioner does not
get damagedprior to being picked up by the
relevant waste disposal center, and contribute
to environmental awareness by insisting on an
appropriate, anti-pollution method of disposal.
Disposal of the packaging of your
new air conditioner
All the packaging materials employed in the
package of your new air conditioner may be
disposed without any danger to the
environment.
The cardboard box may be broken or cut into
smaller pieces and given to a waste paper
disposal service. The wrapping bag made of
polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to
a waste collecting center and used again after
adequate recycling.
Consult your local authorities for the name
and address of the waste materials collecting
centers and waste paper disposal services
nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly,
operation and maintenance of the air
conditioner.
The manufacturer does not accept responsibility for any damages that may arise due
to non-observation of the following
instruction.
Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air
conditioner before openning inlet grill. Never
unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the outlet.
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.
Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or performating the air conditioner's tubes
with sharp or pointed items, crushing or
twisting any tubes, or scraping the coatings
off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in
serious eye injuries.
1
Page 3
Cautions
Do not obstruct or cover the ventilation
grille of the air conditoner.Do not put fingers
or any other things into the inlet/outlet and
swing louver.
Do not allow children to play with the air
conditioner.In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following
situation
1.Applicable ambient temperature range:
Indoor
Cooling
Outdoor
2. If the power supply cord is damaged, it
must be replaced by the manufacturer
or its service agent or a similar qualified
person.
Maximum:D.B/W.B
Minimum:D.B/W.B
Maximum:D.B/W.B
Minimum:D.B
32oC/23oC
18oC/14oC
43oC/26oC
18oC
7. The appliance is not intended for use
by young children or infirm persons
without supervision.
8. Young children should be supervised
to ensure that they do not play with
the applience.
9.Please employ the proper power plug,
which fit into the power supply cord.
10 .The power plug and connecting cable
must have acquired the local attestation.
11.In order to protect the units,please turn
off the A/C first, and at least 30 seconds
later, cutting off the power.
12.When the cabinet A/C is normally working,
if opening the glass door, the machine will
stop working and the panel shows code
"Fc". After closing the door, the code "Fc"
disappears, and the machine will stop
working and then restart automatically,
and renew the original state.
3. If the fuse of indoor unit on PC board is
broken,please change it with the type of
T. 3.15A/ 250V. If the fuse of outdoor
unit is broken,change it with the type of
T.25A/250V
4. The wiring method should be in line with
the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
2
Page 4
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to
the seriousness of possible risks and damages as follows. Compliance to the
instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth
cable.
earthing
Do not install in the
place where there is
any possibility of
inflammable gas
leakage around the
unit.
PROHIBITIONPROHIBITION
Do not get the unit
exposed to vapor
or oil steam.
3
Check proper
installation of the
drainage securely
STRICT
ENFORCEMENT
Page 5
Cautions
When abnormality such as burnt-small found,
immediately stop the operation button and
contact sales shop.
WARNING
Use an exclusive power source with a
circuit breaker
OFF
Connect power supply cord
to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord
in a bundle.
PROHIBITION
Do not start or stop the
operation by disconnecting
the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly
at people, especially at infants or
the aged.
PROHIBITION
CAUTION
Take fresh air occasionally especially
when gas appliance is running at the
same time.
Do not use power supply cord
extended or connected in halfway
PROHIBITION
Do not insert objects into the air
inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct
by yourself.
Do not operate the switch with
wet hand.
PROHIBITION
Do not install the unit near a fireplace
or other heating apparatus.
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the
installation stand
PROHIBITION
Do not place any objects on or
climb on the unit.
PROHIBITION
4
PROHIBITION
Do not pour water onto the unit
for cleaning
PROHIBITION
Do not place flower vase or water
containers on the top of the unit.
PROHIBITION
Page 6
Parts and Functions
Indoor unit
7
HEALTH
SET
TIMER
HUMIDITY
SLEEP
TEMP.
ON/OFF FAN
+
-
TEMP
TEMP
1
Outlet
2
Control panel
3
Inlet grille
4
Air filter(inside)
5
3
4
UV light degerming device (inside)
6
Inlet
7
Anion generator (inside)
5
6
5
Page 7
Parts and Functions
Display board
1. Operation mode display
2. Room temperature display,
Setting temperature display
3. HEALTH display
4. TIMER ON / OFF display
5. SLEEP display
6. POWER / SOFT display
7. ON/OFF button
Used for unit start and stop.
8. MODE button
AUTO COOL DRY FAN
9. AIR FLOW button
10. TEMP button
Used to select your desired temperature.
Outdoor unit
2
1
10
SET
HUMI
TEMP.
6
8
7
ON/OFF
+
TEMP
HEALTH
TIMER
SLEEP
AIR FLOW
TEMP
3
4
5
9
-
HPU-18CU13HPU-20CU13
1
OUTLETCONNECTING PIPING AND ELECTRICAL WIRING
2
INLET
3
4
DRAIN HOSE
6
Page 8
Parts and Functions
19
28
1.RESET
When the remote controller appears abnormal,
use a sharp pointed article to press this button
to reset the remote controller normal.
2.LIGHT button
Control the lightening and extinguishing of
the indoor LED display board.
3. TIMER button
Used to select TIMER ON, TIMER OFF,
TIMER ON-OFF.
4. CLOCK button
Used to set correct time.
5. SLEEP button
Used to select sleep mode.
6. MODE button
AUTO COOL DRY FAN
7. HOUR button
Used to set clock and timer setting.
8. HEALTH button
Used to set healthy operation.
9. ON/OFF button
Used for unit start and stop.
10. TIMER ON display
11. FAN SPEED display
LOWHI
MEDAUTO
12. LOCK display
13. SWING UP/DOWN display
14. SLEEP display
15. HEALTH display
16. Operation mode display
Operation mode
Remote controller
Display board
AUTOFANCOOL DRY
17.Singal sending display
18. POWER/SOFT display
19. Left/right air flow display
20. TEMP display
Remote controller: to display the TEMP. setting.
21. TIMER OFF display
22. CLOCK display
23. TEMP button
Used to select your desired temperature.
24. FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
25. SWING UP/DOWN button
Used to select up or down air sending direction.
26. SWING LEFT/RIGHT button
Used to select left/right air flow.
27. SET button
Used to confirm timer and clock settings.
28. LOCK
Used to lock buttons and LCD display. If pressed, the
other buttons will be disabled and the lock condition
display appears. Press it once again, lock will be
canceled and lock condition display disappears.
NOTE: 1.Cooling only unit do not have functions and displays related with heating.
7
Page 9
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in
remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease
1 min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing,
while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within
7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or
wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving
the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right
2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover
as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-".
request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up.
Please change batteries.
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display
after taking-out, just need to press reset key.
8
Page 10
Operation
HEALTH operation
HEALTH
Display board
Remote controller
TEMP
1.Unit start
Press ON/OFF button, unit starts.
Health function includes health anion function, UV light
degerming function.
2.Health anion function
Press HEALTH button. For each press, is displayed.
Air conditioner starts health anion function operation.
For twice press, disappears,the operation stops.
When indoor fan motor is running, it has healthy
process function. (It's available under any mode)
BRIEF INTRODUCTION TO HEALTH ANION
FUCTION
The anion generator in the air conditioner can generate a
lot of anion effectively balance the quantity of position and
anion in the air and also to kill bacteria and speed up the
dust sediment in the room and finally clean the air in the
room.
About UV light degerming function
UV light emitted by the UV light device of the indoor unit
catalytically activates the nano TiO2 on the multi-lights
touching intermediary, and the degerming effect is highly
efficient and lasting.
Note: when the function is running, don't open the inlet grille.
9
Page 11
Operation
Auto Operation
Display board
Remote controller
TEMP
1. Unit start
Press ON/OFF button, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTOCOOLDRYFAN
Then
3.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
Select Auto operation
LOW
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
MED
HI
4.Unit stop
Press ON/OFF button, the unit stops.
About Auto Operation
Under the mode of auto operation, air conditioner will
automatically select Cool or Fan operation according
to room temperature.And temp.setting is disabled.
10
AUTO
Page 12
Operation
Cool Operation
Display board
Remote controller
TEMP
1. Unit start
Press ON/OFF button, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTO
Then Select COOL operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1oC, if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
COOLDRYFAN
LOW
MED
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
HI
5.Unit stop
Press ON/OFF button, the unit stops.
11
AUTO
Page 13
Operation
Display board
Remote controller
Dry Operation
TEMP
1. Unit start
Press ON/OFF button, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
COOL operation starts when room
temp.is higher than temp.setting.
Temp.setting+2oC
Temp.setting
On reaching temp.setting +2oC
unit will run in mild DRY mode.
Ultra-low air flow
AUTO
COOLDRYFAN
Then Select DRY operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
LOW
MED
HI
Air conditioner is running under displayed fan speed.
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
AUTO
5.Unit stop
Press ON/OFF button, the unit stops.
12
Page 14
Operation
Display board
Remote controller
Fan Operation
TEMP
1. Unit start
Press ON/OFF button, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
AUTO
Then Select FAN operation
COOLDRYFAN
3.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
LOW
MED
HI
4.Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in
COOL mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.
13
Page 15
Operation
Air Flow Direction Adjustment the cabinet type
1.Status display of air sending
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
Fig. 1
2.Up and down air flow direction
For each press of button, air flow direction on remote controller displays as
follows according to different operation modes:
The vertical flap will swing according to the above positions
NOTE: When we stop the air conditioner with remote controller or controlling plate, the flap
will close automatically. If we cut off the power directly, the flap could not close itself.
So you should shut off the machine with remote controller or controlling plate, You
MUST NOT cut off the power when the machine is running.
3.Left and right air flow direction
For each press of button, remote controller displays as follows :
remote controller:
Horizontal louvers:
The horizontal louvers will swing according to the above positions.
Before going to bed, you can simply press the
SLEEP button and unit will operate in SLEEP
mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts, set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
become 1OC higher than temp. setting. After
another 1 hours, temp. rises by 1OC further.
The unit will run for further 6 hours then stops.
Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
Remote Controller
TEMP
SLEEP operation startsSLEEP operation stops
Temp.setting
In AUTO mode
2.
The unit operates in corresponding sleep
mode adapted to the automatically selected
operation mode.
3. In FAN mode
It has no SLEEP function.
SLEEP
1 hr
Rises 1OC
1 hr
In COOL, DRY mode
Approx.6hrs
Rises 1OC
Unit stop
4.Set the wind speed change when sleeping
If the wind speed is high or middle before
setting for the sleep, set for lowing the wind
speed after sleeping.
If it is low wind, no change.
15
Page 17
Operation
Timer On/Off Operation
Display board
Remote Controller
TIMER
TEMP
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2. Timer mode selection
Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFFTIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or
TIMER OFF). " "or " "will flash.
3.Time setting
Press HOUR button.
Every time the button is pressed, time setting
increases 1 min, if kept depressed, it will increase
rapidly.
Every time the button is pressed, time setting
decreases 1 min, if kept depressed, it will decrease
rapidly.
It can be adjusted within 24 hours.
4.Confirming your setting
After setting correct time, press SET button to confirm
" "or" "on the remote controller stops flashing.
Time displayed: Unit starts or stops at x hour x min.
(TIMER ON or TIMER OFF).
5.Cancel TIMER mode
Just press TIMER button several times until TIMER
mode disappears.
Hints:
After replacing batteries or a power failure happens, time setting should be reset.
Remote controller possesses memory function, when use TIMER mode next time,
just press SET button after mode selecting if time setting is the same as previous one.
16
Page 18
Operation
Display board
Timer On-Off Operation
TIMER
TEMP
Remote Controller
Set clock correctly before starting
TIMER operation.
1. After unit starts, select your
desired operation mode . Operation mode will be
displayed on LCD.
2. Timer mode selection
Press TIMER button to change TIMER mode. Every time
the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFFTIMER ON-OFF
Then select your desired TIMER mode (TIMER ON - OFF).
" "will flash.
3.Time setting
Press HOUR button.
Every time the button is pressed, time setting increases
1 min, if kept depressed, it will increase rapidly.
Every time the button is pressed, time setting decreases
1 min, if kept depressed, it will decrease rapidly.
It can be adjusted within 24 hours.
4.Timer confirming for TIMER ON
After setting correct time, press TIMER button to confirm
" " on the remote controller stops flashing.
" " starts flashing.
Time displayed: Unit starts or stops at x hour x min.
5.Time setting for TIMER OFF
Just press HOUR button ,follow the same procedure in
"Time setting for TIMER ON"
6.Time confirming for TIMER OFF
After time setting,press SET button to confirm.
" " on the remote controller stops blinking.
Time displayed:Unit stops at x hour x min.
To cancel TIMER mode
Just press TIMER button several times until TIMER
mode disappears.
According to the Time setting sequence of TIMER ON
or TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
17
Page 19
Operation
Fan speed display
Remote controller
Remote controller:
TEMP
When adjusting FAN speed during system
operation, every time the FAN button is
pressed, the fan speed changes as follows:
4321234
AUTOLOMEDHI
Control panel:
AUTO: zones1-4 circularly light
LO: zones 1-2 normally light
Display
1.The control sepuence of back light on the panel
Press Point Light Button on the remote controller each time,
the LCD display will change in order as follows:
Back light source ON
Beeper no sound
2.About the control of the backlight sounce color on the panel
Function Standard color Priority Function Standard colorPriority
AUTO
COOL
FANBrick red1
White
Blue
Back light source ON
Beeper sounds
1
1
MED: zones 1-3 normally light
HI: zones 1-4 all light
Back light source OFF
Beeper sounds
DRY
HEALTHGreen2
Light blue
1
When the backlight source is lighting, the source color displays corresponding to the table
function columns.When two functions or more are working, the backlight source colors display
based on the priority in sequence 2,1.
Test operation
Test operation switch is the same as emergency switch.
ON/OFF
Use this switch in the test operation when the room temperature
is below 16OC, do not use it in the normal operation.
Keep pressing the "Mode" and the "Temp-" at the same
TEMP
time for more than 5 seconds. After you hear the "Pi" sound
twice, release your fingers from the buttons: the cooling operation starts with the air flow
speed "Hi".
Unit stop (cancel the Test operation:)
press the ON/OFF button once, then you will hear "Pi" sound and the unit will operate as
what the remote controller shows.
When you connect the power supply, all the signs of function will be displayed for 5
senconds. Then the room temperature will be shown on the display board.
When the buttons on both panel and remote controller are pressed, you will hear the sound
from the unit
MODE
+
FAN
TEMP
-
18
Page 20
Operation hints
Operating the conditioner
If the ambient humidity is too large, the anion effect will be reduced. Under the cooling or
dehumidifying mode, the horizontal air door blade shall not keep the downward position
for a long period.Otherwise the air outlet will condense water and produce water drops.
Do not expose your skin under cool air or hot air for a long period.
Remote monitoring
The control board of the indoor unit reserves the communication port for remote control. If
you install the peripheral equipment according to the manual of the matching remote control
detector, it can realize the computer management or remote monitoring of the conditioner.
Please refer to the manual of the "Conditioner remote control detector " for the details.
Trouble display
If the conditioner has trouble, the control panel will display "E ". Please switch off the
power supply, and restart the machine. If it still displays the error code, please switch
off the power supply, and contact the local after-sales technicians for maintenance.
Power failure resume (please set and apply as necessary)
With setting of power failure resume, if sudden power failure occurs, the unit will resume
original operation when power is supplied again.
Setting method:
With ON of remote controller(except TIMER and FAN),repeatedly press SLEEP button 10
times in 5 seconds,after 4 Beep from the buzzer, the unit comes into power failure resume
mode.
To cancel:
Press SLEEP button continuously 10 times in 5 seconds, the buzzer sounds Beep twice
and power failure resume function is canceled.
Note:
When sudden power failure happens during unit operation in power failure resume mode,if
the air conditioner is not desired for use in a long period, please shut off the power supply
in case that the unit automatically resume operation when power is re-supplied, or press
ON/OFF to turn off the unit when power resumes.
19
Page 21
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room
temperature
Proper
temperature
Close doors and windows
during operation
During cooling
operation prevent
the penetration of
direct sunlight with
curtain or blind
Do not block the air inlet
or outlet
Use the timer effectively
If the unit is not to be used
for a long time, turn off the
power supply main switch.
OFF
20
Use the louvers effectively
HEALTH
SET
TIMER
HUMIDITY
SLEEP
TEMP.
ON/OFF FAN
+
-
TEMP
TEMP
Page 22
Maintenance
For Smart Use of The Air Conditioner
WARNING
Before maintenance,be sure to turn off the system and the circuit breaker.
Remote Controller
Do not use water, wipe the controller with a
dry cloth.Do not use glass cleaner or chemical
cloth.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser may
damage the coating of the unit.
Air Filter cleaning
Indoor Body
Wipe the air conditioner by using a soft and
dry cloth.For serious stains,use a neutral
detergent diluted with water.Wring the water
out of the cloth before wiping.then wipe off
the detergent completely.
Hot water over 40OC(104OF) may cause
discoloring or deformation.
Press the clasp on the top of the grill and pull the grill out,
and then the filter will be taken out along a gradient way.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with
water.After washing, dry the filter completely in the shade.
Then, reinstall it onto the unit.
21
Once every
two weeks
Page 23
Maintenance
To Keep Your Air conditioner in Good Condition
after Season.
1. Operate in FAN mode for about half a day.
On a fine day, unit shall be started and operate in
FAN mode for about half a day until the inside of
the unit becomes thoroughly dry.
2. Put off the power supply cord.
3. Cleaning the body.
4. Take out the batteries from the
wireless remote controller.
22
Page 24
Maintenance
Before Setting in High season
1. Cleaning the standard air filter.
Operation without filter may cause troubles.Be sure
to attach both right and left filters prior to the operation.
Each of them are of different shapes.
2. Connecting the earthing cable.
Caution
Incomplete earthing may cause an electric shock.
3. Do not block the air inlet or outlet.
4. Plug-in
Caution
After brush away dust at the plug, insert the plug of
the power supply cord into the outlet completely.In
case of suing exclusive circuit breaker,switch on the
circuit breaker.
EARTHING
NO WET HAND
23
Page 25
Trouble shooting
Before asking for service, check the following first.
Normal
Performance
inspection
Phenomenon
The system does not restart
immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have elapsed
to protect the system.
When the electric plug is pulled out and
reinserted, the protection circuit will work
for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing
or gurgling noise may be heard. At first 2-3
minutes after unit start, this noise is more
noticeable. (This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking noise may
be heard. This noise is generated by the
casing expanding or shrinking because of
temperature changes.
Should there be a big noise from air flow in
unit operation, air filter may be too dirty.
This is because the system circulates smells
from the interior air such as the smell of
furniture, cigarettes.
During COOL or DRY operation, indoor unit
may blow out mist. This is due to the sudden
cooling of indoor air.
Multiple
check
Does not work at all.
Poor cooling
Is power plug inserted?
Is there a power failure?
Is fuse blown out?
Is the air filter dirty? Normally it should be
cleaned every 15 days.
Are there any obstacles before inlet and outlet?
Is temperature set correctly?
Are there some doors or windows left open?
Is there any direct sunlight through the
window during the cooling operation?(Use
curtain)
Are there too much heat sources or too many
people in the room during cooling operation?
24
Loading...