FAQ
Before Usage
Phenomenon Conf irmation items Remedy
No power to heater Check power
Only cold water
and pointer not
light when heat
Heating pointer
always light
temperature of water
icient hot
water
Packing List
Before Usage
Name
Quantity 1 1 1 2
Note
This appliance is not intended for use by persons (including children) with reduced physical
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
water heater
Before Usage
1
Uncontrollable thermostat
2
Setting water temperature not
1
obtain
Uncontrollable thermostat
2
Unconstant water pressure
Temperature set too low Adjust setting water temperature
1
Excessive water pressure
2
Electric
(set)
Safety valve
(pcs)
Drain hose
(ply)
Contact with service department
when 1 is excluded.
Keep heating
Contact with service department
when 1 is excluded.
use with constant water pressure
Expansion
bolt
(pcs)
Expansion
hook
(pcs)
2 1
User's
manual
(copy)
Haier Household Elec tric Wa ter Heater
User ’s Manual
ES25H-H1(H)
FCD-JTHA30-III(ET)
FCD-JTHA40-III(ET)
FCD-JTHA50-III(ET)
FCD-JTHA60-III(ET)
FCD-JTHA80-III(ET)
Haier Americ a
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout
the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material resources. To return your used device,
please use the return and collection systems or contact the retailer where the product was purchased.
They can take this product for environmental safe recycling.
Pre-safe Expert
Before Usage
Mark of
Haier Safe Water Heaters
Before Usage
Before Usage
Dear users,
Thanks for choosing Haier water heater product.
Haier products have good quality and excellent performance. To facilitate you to use the
product, please read the manual and operate accordingly. Please retain it for future reference.
The international star service of Haier Group will always accompany you. No matter what kind
of problems you meet in usage, please contact with the local after-sales service agent. We are at
your service all the time. Thanks again for choosing Haier Product.
The water heater you purchased may not full comply with the manual due to the improvement
of product. We apologize for the inconvenience occurred therefrom.
New York, NY 10018
Printed in Chin a
0040500304
2010/07/26
This mark is the designation for Pre-safe Expert of Haier Water Heater
Company, which indicates use of the company's patented technology
inside the product. It ensures you a safe bath while monitoring
whether your house ground wire is live or not all the time. If this
mark is lighted on, it indicates your house ground wire has come live
(poor grounding and live). In this case, please immediately stop use
and disconnect the power, and remember not to touch any electric
appliance shell in your house. At the same time, immediat
after-sales service and your property management company for
Pre-safe Expert will become the electric safeguard for your family.
ely contact
� Please read this manual before usage
� Retain it for future reference
� See the physical product for the appearance, colour or pattern
Parameters
Before Usage
Rated voltage/
Frequency
220V~,50Hz 500W IPX4 See to Figure1
220V~,50Hz 800W IPX4 See to Figure1
220V~,50Hz 1200W IPX4 See to Figure1
220V~,50Hz 1500W IPX4 See to Figure1
230V~,50Hz 1650W IPX4 See to Figure1
230V~,60Hz 1650W IPX4 See to Figure1
230V~,50Hz 2000W IPX4 See to Figure1
220-240V~, 50/60Hz
All the rated power mentioned above are available for this model. For more details, please refer
to the nameplate.
Dimensions
Before Usage
Front view Cutaway view Bottom view
Rated
power
1650W IPX4 See to Figure1
a1
Rated
pressure
0.80MPa
0.80MPa
0.80MPa
0.80MPa
0.80MPa
0.80MPa
0.80MPa
0.80MPa
b1
Waterproof
grade
Dimension/
Weight/Volume
Tap water pressure Attestation
no less than 0.05MPa
no less than 0.05MPa
no less than 0.05MPa
no less than 0.05MPa
no less than 0.05MPa
no less than 0.05MPa
no less than 0.05MPa
no less than 0.05MPa CE
/
/
/
/
/
/
/
(Figure 1)
e1
Features
Before Usage
1
Safety
High-quality heat proof stainless steel electric heating element, overtemperature protection;
overpressure protection of tank; safe and reliable.
"Safe Care" patented design together with the function of monitoring and displaying of live
ground wire has become a real safeguard for family safety.
Durability
2
The shell adopts dusting anticorrosion treatment, handsome and durable enamel tank, with
reliable quality and long operation life.
Convenience
3
Adjustable heating temperature. Adjustable water temperature.
Adjusting range: water inlet temperature~75°C .
Multiple usage
4
Enclosed structure, capable of supplying water to multiple places like toilet, kitchen etc.
Suitable for family, enterprises, service trades like beauty care on hot water supply (not
drinkable).
5
Nice molding, horizontal type wall-mounting design, saving space.
The water heater you purchased is the improved model of the series product. Please operate
according to the user's manual.
1 2
A
B
Net
(kg)
Rated
temperature
(°C)
L
N
E
a1
(mm)
b1
(mm)
c1
(mm)
MT
d1
(mm)
e1
(mm)
BT
Volume
Model
ES25H-H1(H) 25 15 75 569 385 100 192 350 200
FCD-JTHA30-III(ET) 30 15 75 569 385 100 192 350 200
FCD-JTHA40-III(ET) 40 16.5 75 688 385 100 200 350 200
FCD-JTHA50-III(ET) 50 18.5 75 694 440 100 220 400 200
FCD-JTHA60-III(ET) 60 20.5 75 795 440 100 305 400 200
FCD-JTHA80-III(ET) 80 26.5 75 991 440 100 521 400 200
Remarks: The permitted error limit of above parameters is ±10%.
Electric Circuit Diagram
Before Usage
L: Brown wire
N: Blue wire
MT: High temperature limiter
BT: Thermostat
HL: Heating indicator
EH: Heating element
E: Yellow/green wire
(L)
weight
A. Hot water outlet
f1
(mm)
B. Cold water inlet
C. Heating element
D. Enamel tank
E. Wall-mounting
bracket
F. Magnesium anode
rod
EH
HL
E
CSH10D0810.indd 1 2010/5/7 10:03:04
Description of the Symbols
Never do that
Safety Precautions
Before Usage
Check if the ammeter and the diameter
of the wires are in accordance with
the rated current of the water heater.
If necessary please have it checked by
experienced electrician.
After installation, be sure to fill the
heater completely with water before
switching on the power in the first
usage. Children must take bath
under the supervision of adult.
In winter of cold area, if the heater is
idle for a long period, please pull the
handle of safety valve to discharge the
water. Otherwise it may freeze inside
the water heater and cause damages.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety.Children should be supervised to ensure that
they do not play with the appliance.
The product adopts the patent "Safe Care" technology of our company. As long as adopting civil
power supply, even if the earthing wire is electrified by mistake, the "Safe Care" technology still
can block the dangerous electricity, and ensure your personal safety. But if you find perceptible
current, please disconnect the power and contact local after service department for maintenance.
Do not disassemble by yourself.
Setting Environment
Before Usage
Do not set it at place where it is too
cold and may freeze.
appliance.
Do not install to places without
sewer.
The original pipeline of the water heater is an organic part of "Safe Care". Do not remove it by
yourself.
Otherwise we will not take responsibility for the injure and loss caused by the safety trouble
occurred therefrom.
3 4
Be sure to act as per instructions
The product is only available for
alternating current . Be sure to use
independent power and earth it
reliably. Set the power of the water
heater at dry position away from
water spraying.
In opening and closing the water
valve, do not point the shower head
to human body. Otherwise it may
hurt by the spraying hot water.
In case the power cord of the water
heater is damaged, be sure to have it
replaced by after service technicians
manufacturer.
Do not set at outdoor places.
Please mount it to firm and reliable wall.
In case connecting water heater with
water drain hose, connect the drain
hose to the inlet of the sewer to
avoid polluting by splashing.
Installation
Before Usage
Installation must be made by installers or designated personnels of our company's after-service
department. The water heater shall be wall-mounted.
If there is no power cord or plug and the power is not interrupted, the fixing line connected must
be equipped with the all-pole disconnection device provided by breakaway contact under the
overvoltage type III condition according to wiring rules.
location. Make four holes ∅12mm, 65mm deep in the wall with an impact drill according to
installating dimension. Insert fix expansion hooks and expansion bolts in corresponding wall
holes. Lift the water heater. Insert wall rack onto the hooks and bolts. Fit at washers, rear wires
and nuts in turn onto the bolts (see Figure 2). Tighten the nuts and check them firm. Install
accessories such as safety valve, drain hose as shown in Figure 3. Use sealing compound to
prevent water leakage.
o facilitate installation and removal, it is suggested a G 1/2" movable nut is fitted at appropriate
T
locations on inlet and outlet pipes respectively. Find water supply location. Connect inlet pipe,
outlet pipe and city water pipe respectively to the use point.
The hot water pipe shall not be too long to reduce the heat losses.
Please reserve some space in installation for the future maintenance.
If there is no plug and the power is not interrupted,the fixing line connected must be equipped with the
all-pole disconnection device provided by breakaway contact under the overvoltage type III condition
according to wiring rules。
H
Hot
water
et
(Figure 2)
old water
Hot water
outlet valve
(Figure 3) for reference in installation only
Cold water
outlet valv
outlet valve
Mixing valve
ng valve
outlet
Cold water inlet
ld water inl
hower hea
Shower head
ety valve
Safety valve
The safety valve should be connected to the cold water inlet pipe. Please check carefully if the
direction is correct after installation. The correct direction of installation is that the arrowhead on
the safety valve should point to the water heater.
Please connect the drain hose to the safety valve. Connect one end of the hose to the safety valve
vent and the other end to the sewage drain. The hose can be cut short or extended as necessary.
The hose shall be installed as inclined downward. (see to Figure 4)
The water may drip from the discharge pipe of the pressure relied
device and that this pipe must be left open to the atmosphere and
installed in a continuously downward direction and in a frost-free
environment. Check safety valve once a month as follow: move
the small handle of safety valve, if there's water flowing out, safety
valve is normal; if there's no water flow, please contact local
after-sales service station.
The pressure relief device is to be operated regularly to
remove lime deposits and to verify that it is not blocked.
You also can drain the water heater through the safty valve.
pressure release hole
(Figure 4)
Attentions in Installation
Before Usage
During installation, adequate space must be reserved for future maintenance and repair. If
the water heater is installed within decoration boards, the right board shall be removable to
facilitate removing the plastic cover during maintenance.
City water inlet pressure shall not be less than 0.05MPa, Max
imum pressure can not exceed
0.75MPa.
Electric water heater shall be installed indoors with ambient temperature above 0°C. The pipes
shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer
than 8m, hot water pipe shall have a thermal insulation to minimize heat loss.
The mounting wall shall be firm and reliable to support four times the weight of water
heater full of water. Non-load bearing walls or air brick walls must have corresponding
protective measures like additional support, wall-through screws or back boards.
Electric water heater shall be located in a place easy for use, m
aintenance and with a floor
drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. The
installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe,
which will cause a suppressed or unsafe feeling to users.
Power for water heater shall be in a dry place free of water splash. (splash-proof box is
preferred).
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated
position with no random modification.
All water pipes should be installed by qualified water pipe installation workers. The pipelines
should comply with the national standards and regulations on the prohibition of prevention
tools todraw water to water source pipelines by way of inverse siphon, as well as local
building codes.
The pipelines must be installed by qualified tap water pipe installation personnel. The pipelines
must comply with applicable national standard that specifies preventing of non-drinking water
in the appliances from being siphoned back to the water source as well as local construction
regulations.
Operation Instructions
Before Usage
For the first use after installation, due to the dryness of the tank, first the city water inlet valve
from the showerhead or other outlets (the tank is full). Check connections are free of water
leakage, and connect power.
Turn the knob to set your desired water heating temperature, which can be stepless changed
between cold water inlet temperature and 75°C. In heating mode, heating lamp is lighted on.
Normally the knob shall be positioned at highest temperature. This machine has a thermostat
setting value, and switch on again when water temperature decreases to certain value.
City water pressure
≥
0.80MPa will cause much water fiowing out from safety valve presuure
relief vent. This is due to too high water pressure. Please ask after-sales service for correction.
Before Usage
Attentions in Operation
To avoid causing machine troubles, do not connect power before tank is full of water.
1
Adjust a suitable temperature before use, for water temperature above 50°C may burn your skin.
2
This product is closed water heater, which can supply hot water through pipe connection to
3
several points like bathroom (bathtub, washbasin, showerhead) and kitchen.
5 6
4
long-term out-of-use or maintenance, you can close city water pipe valve, open mixing valve
to hot water range, and move up safety valve handle to drain the tank. To avoid injury, before
next use, it is suggested to first open hot water valve before switching on the water heater,
exhausting gas possibly retained in the pipeline. In this case, no smoke or fire is permitted
near the open valve. Carefully check and confirm all parts are in good condition.
Provided hot water quantity can meet use demand, temperature setting shall be possibly low.
5
It can minimize heat dissipation, high-temperature corrosion and sedimentation, ensuring a
longer service life.
Regularly ask servicemen to make safety inspection, remove sediment on heating elements,
6
and check consumption of anode bar. Too much consumed anode bar shall be replaced.
Cleaning and Maintenance
Before Usage
Statement: This water heater shall only be repaired and maintained by qualified servicemen.
Improper maintenance may cause severe injur y or damage. Before opening or
repairing water heater, please do disconnect power supply.
Note: Before asking for service, please refer to troubleshooting section to resolve easy problems.
External Cleaning: Disconnect power supply before cleaning. Gently wipe with wet cloth
dipped wit
h a little of mild detergent. Do not use gasoline or other solvents. Finally dry
with dry cloth. Keep water heater dry. Do not use cleansers containing grinding agent (e.g.
toothpaste), acids, chemical solvents (e.g. alcohol) or polishers to clean.
Internal Cleaning: To ensure high working efficiency, heating elements and tank liner of water
heater shall be cleaned once in three years. Take care not to damage protection layer on
use habits, magnesium rod shall be periodically replaced. If maintenance is needed, please
contact local service station.
FAQ
Before Usage
Phenomenon Conf irmation items Remedy
No water supply or water
No water
Only cold water but
pointer light when
heat
1
pressure too low
Hot water access close Check and clear
2
Hot water access close Check and open
1
Temperature not set to desired
2
setting
Heating time limit and setting
3
temperature not obtained
Defective heater
4
Check
Adjust temperature of water
Keep heating
Contact with service department
when 1 2 3 are excluded.
(To be continued)
CSH10D0810.indd 2 2010/5/7 10:03:06