Instantaneous Water Heater
Operation Manual
Model:
EI39G1M(W)
EI39G1M(S)
In case of any abnormality or scorching smell of
the water heater, please cut off the power supply
immediately and contact the service center.
Do not touch the power supply with wet hands, so as
to prevent it from getting wet by water. If it is wet by
accident, it must be inspected and confirmed by the
professional personnel appointed by our company
before reuse to prevent electric shock.
In order to ensure safety, the power supply of the water
heater should be reliably earthed, otherwise, it is strictly
prohibited to use the water heater. The test pencil should
be used to determine whether the live wire and the
neutral wire are connected reversely.
Make sure to use an independent power supply.
0040510390
V
Please read this manual carefully before use
Please keep this manual properly for reference.
(please read before use)
One dimensional code 60mm*10mm
Symbol interpretation
Indicates the act that must be forbidden
Indicates the act that must be carried out
Caution
Our company will not bear any responsibility for incorrect installation and use of
this water heater!
Note:
Failure to follow this manual means the risk of accident, property loss and personal injury.
The water heater must be repaired or maintained by qualified professional personnel.
Improper operation may cause serious personal injury or property loss.
Indicates the matter which must be paid attention to
1 2
switch matched with the water heater must be used
This appliance is not to be used for a potable water
supply.
Product specification
Electrical Schematic Diagram
TB: Terminal Block
ER: ELCB Ring
RT2: Water-out Sensor
FL: Flow Sensor
MT: Thermal Cut-Out
HE: Heating Element
Display
Board
diameters meet the rated current of the water
Caution
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Caution
YELLOW
RT2
FL
Control
Board
&GREEN
COM
NO
COM
NO
BROWN
BROWN
YELLOW&GREEN
BLUE
BLUE
BLACK
Triac Board
MT
HE
YELLOW
&GREEN
BLUE
TB
ER
BROWN
hot water
N
L
Technical parameter
Model
Rated power-Rated
current
AC 240 V
Rated Frequency
Waterproof Grade
Rated Pressure
Maximum water-out
temperature
Minimum inlet pressure
Maximum inlet pressure
Start flow
Outline dimension
Net weight
EI39G1M(W) EI39G1M(S)
3950-16.5
0.02MPa
0.6MPa
1.5L/min
360 mm*200 mm*85
1.85kg
W-A
50
IP25
MPa
0
50
Hz
o
C
mm
Introduction to components
Crimping
board
Temperature
controller
Heating
element
Stainless
steel circlip
Water-out
temperature
sensor
Water-out
pipe
Note:The allowable error range of the net weight is ±10%.
Three-gear
EI39G1M(W)
EI39G1M(S)
heater
(Set)
1 1
sprinkler
(Set)
1
7. The test pencil should be used to determine whether the live wire and the neutral wire are connected
reversely.
Terminal block
Inductor coil
8. The outlet must not be connected to any tap or fitting other than those specified.
9. The water heater is equipped with the flow control valve. For use safety, the flow control valve should be
installed on the water-in pipe, and it is strictly forbidden to install the valve at the outlet of the water heater.
10.The water inlet of this appliance shall not be connected to inlet water obtained from any other water heating
Computer
board
system.
11.Metallic / chromed hose and conductive control valve shall not be used!
Installation of whole machine
Flow sensor
Indicator
board
Water-in pipe
package
(Set)
1
1
1.Remove the front shell
screws and the front shell.
2.Remove the power cord
plug of the rear shell.
3. Install the power cord corresponding to
the live wire, neutral wire and earth wire
respectively, and fix it by wire nail.
Installation guide
Precautions for installation
1. The load-bearing wall for installing the water heater should be able to bear twice the weight of the water
heater filled with water.
. The water heater should be installed indoors and in a non-icing place, with pipes arranged centrally.The hot
2
water outlet should not be too far away from the hot water use point. If the distance exceeds 2m,the hot water
pipe should be insulated to reduce heat loss.
3
.
The water heater should be installed in a place that is convenient for use and maintenance and has a sewer
to ensure that surrounding or lower facilities cannot be damaged when water heater or water pipe leaks. Please
do not install the water heater in a place that can be sprayed directly or is prone to icing.
4. Because of the high power of this water heater, before installing the water heater, please carefully check
whether the ammeter and power wire diameters (2.5mm 2recommended) and fuse meet the rated current and
voltage requirements of this water heater. If necessary, please ask a professional electrician to check the circuit.
5. Do not connect the water-in and water-out pipes reversely; Under no circumstances should the outlet be
blocked.
6. To ensure safety, the water heater should use the standard single-phase bipolar air switch or circuit breaker
(in the case of circuit breaking, the open distance of all contacts should be at least 3mm so as to reliably cut off
the connection with the external power supply during maintenance), and be earthed reliably, with the earthing
resistance of the household earth wire less than 4Ω. Because the water heater requires a large current,the
incoming power supply of the water heater must be directly connected with the air switch, and the power plug
should not be used.
3
4. Confirm the installation position of the water heater, and drill four φ6X35mm holes on the load-bearing wall
with impact drill, with the spacing as shown in the figure below (it is also allowed to correspondingly locate
the four fixing points by placing the rear shell on the wall). And then, drive four expansion bolts into four holes
respectively, hang up the machine,and fix the machine with screws.
163(mm)
319(mm)
4

5. Install the flow control valve on the water-in pipe.
6. Fix the sprinkler pedestal in a suitable
position on the wall.
COMBOMASSAGERAIN
Three-gear sprinkler
pedestal model)
Adjustable wall
bracket
Expansion
screw
gasket at the connecting ports on both ends
sprinkler hose and the sprinkler in the
counterclockwise direction.
Sprinkler
O-ring rubble gasket
Sprinkler hose
installation step figure
Water saving
card
diameter of 6mm and a depth of 35mm in a
suitable position on the wall with an electric
is
、
4).
Complete the installation (put the
3).
sprinkler and the sprinkler hose connector
on the adjustable wall bracket).
Select the sprinkler mode (adjust the
adjustment knob at the lower part of the
sprinkler board to the left or the right to select
the sprinkler’s water-out mode).
L R
5
6
℃
Heating indicator:
Electric leakage indicator: When electric leakage is detected, the indicator
flashes.
button
Stepless knob switch: adjust temperature
Cleaning
Not used for a long time
If you need to stop using the water heater for a long time, please take the following steps:
1. Cut off the power supply.
2. Close the tap water valve.
3. In order to avoid injuries when the water heater is reused, it is recommended to carefully check
whether all components of the water heater are in good condition and whether the pipes leak by water
supply before turning on the power supply of the water heater.
Is the water supply cut off or water switch is not
No water or
less water
①
②
pipe
turn on the water switch.
Carry out inspection and clean or
replace the filter screen.
1.All the indicators are on after the power is turned on, and are off after 2s, then enters the shutdown
state.
the start-up flow rate,the highest set temperature is reached.
●
●
7 8
temperature
out
code on
display screen
①
②
③ Confirm not ① ②
①
② The status indicator only flashes blue.
③ The status indicator flashes red and blue
alternately.
power supply to resume.
Increase the set temperature.
Cut off the power supply and contact the
Cut off the power supply and contact the
Cut off the power supply and contact the