For the sake of safety and in order to use the air conditioner correctly, please read this manual and the operation manual of indoor unit carefully before using
After reading this attached manual, please keep it properly. If the user is changed, please do give this manual to him
Characteristics of Products
Characteristics of Products
1.220~230V normal power, suitable for both commercial use and home use.
2.Free choice of wire control and remote control.
3.Several types of indoor units, free combination of specification.
4.Single outdoor unit, space-saving and cost-saving.
5.Far distance network technology , realize the intelligentized living area (For details, please refer to the manual of indoor unit).
6. POWER FAILURE RESUME FUNCTION. Automatic set when power resumes.
Safety Precautions
The following lists four kinds of safety precaution items and suggestions:
!
Warning: Improper use may cause death or serious injury.
!
Notice: Improper use may cause body hurt or unit damage; in some circumstance, it may cause serious results.
: Those contents marked with ìProhibitionî are definitely prohibited action, otherwise, it may cause unit damage or risk to usersí safety.
: Those contents marked with ìForcedî are definitely forced action, otherwise, it may cause unit damage or risk to usersí safety.
The following safety precautions must be observed. This safety precautions should keep in hand for reference.
Warning
!
Commissioned installation The installation work should be done by the after-sales service worker. Self­installation may cause water leakage, electric shock and fire accident because of improper installation.
It is strictly prohibited to rebuild the air conditioner by yourself. Improper rebuilding may cause fire, electric shock and water leakage.
If abnormal conditions (sear smell) occur, please stop the unit, turning off the electric power and contact the after-sales service center for solution.
If still using the unit under this circumstance, the air conditioner may be damaged and may also cause electric
Cut off power
shock or fire accidents. When needing repair, please ask the after-
sales service work for help. Improper maintenance and repair may cause water leakage, electric shock and fire.
During the unit operation, do not insert fingers or other articles alike into the air inlet, outlet and louver. Because the high-speed fan is very dangerous, it may cause hurt.
Ask after-sales service worker to take measure to prevent refrigerant from leaking. If the leaked refrigerant exceeds a certain density , it will cause lack of oxygen. If the room installed with air conditioner is too small, do take enough measure in order to avoid lack of oxygen even if refrigerant leaks.
When the air conditioner must be dismantled and reinstalled, please ask the after-sales service center to do this work. Improper installation may cause water leakage, electric shock and fire.
After a long-time using of the air conditioner, please check if the foundation of the unit is damaged. If the foundation is damaged without repair, the unit may fall down leading to body hurt.
Any inflammable spray liquid cannot be place or use near the air conditioner, otherwise, fire accident may happen.
Only after stopping the unit and cutting off power can clean the air conditioner to avoid electric shock or injury.
1
Name of Parts
1
2
3
4
1
Air inlet
Air outlet
2
Air inlet
3
Repair panel
4
Note:
Do not block the air inlet and air outlet, otherwise the performance of the air conditioner may be lowered.
2
Installation procedure
Install indoor unit
1.Choose installation place
The chosen installation place should meet the following requirements and get the userís consent. Place air can freely circulate.
>30cm
Place can perform level installation. The condensate water can be drained smoothly. Place where the noise and hot air will not
disturb the neighbors. Place can ensure the space for successful maintenance and repair.
>10cm
>10cm
>15cm
>60cm
Place where the four corners of the unit are easily installed and leaves at least 1m height space.
Place where the wall hole is easy for drainage. When installing multiple units, make sure to leave enough space to
avoid air short-circuit.
If the outdoor unit near the street, it should not be lower than 2.5m. Please install in the place that can sufficiently bear the weight of the
unit. The air conditioner cannot install on a non-special metal frame (e.g. theft guard net). Install in the place with intensity as high as possible to prevent the noise and vibration from spreading to other places. Avoid the place where the strong airflow directly toward the air inlet or air outlet. Avoid the place where high frequency electromagnetic waves are generated to prevent the communication of indoor and outdoor from being affected. Avoid the place where the combustible gas exists. The combustible gas around the air conditioner may cause fire. Avoid the place where the combustible gas may be leaked. If the leaked gas gathers around the air conditioner, it may cause fire accident. Avoid the place with to much oil, vapor and salinity, such as, seashore and hotspring area and the area with sulfurated gas, etc. corrosive gas. If install in these places, the air conditioner needs special maintenance. Avoid the place where the heat source directly radiates or with other heat sources.