Haier Network Air Conditioner
Free Combination Multi-split Type Room Air Conditioner
Outdoor unit
AU422BIBAA
CONTENTS
To User
Safety Precautions
Name of Parts
Installation Instruction
Electric Wiring
Operation and Performance
Troubleshooting
Pipe System Chart
Inside front cover
1
2
3-6
7-10
11
12-13
14
No.*0010571564
For the sake of safety and in order to use the air conditioner correctly,
please read this manual and the operation manual of indoor unit carefully
before using
After reading this attached manual, please keep it properly. If the user is
changed, please do give this manual to him
Characteristics of Products
Characteristics of Products
1.220~230V normal power, suitable for both commercial use and home
use.
2.Free choice of wire control and remote control.
3.Several types of indoor units, free combination of specification.
4.Single outdoor unit, space-saving and cost-saving.
5.Far distance network technology , realize the intelligentized living area
(For details, please refer to the manual of indoor unit).
6. POWER FAILURE RESUME FUNCTION. Automatic set when
power resumes.
Safety Precautions
The following lists four kinds of safety precaution items and suggestions:
!
Warning: Improper use may cause death or serious injury.
!
Notice: Improper use may cause body hurt or unit damage; in some
circumstance, it may cause serious results.
: Those contents marked with ìProhibitionî are definitely prohibited action, otherwise,
it may cause unit damage or risk to usersí safety.
: Those contents marked with ìForcedî are definitely forced action, otherwise, it may
cause unit damage or risk to usersí safety.
The following safety precautions must be observed.
This safety precautions should keep in hand for reference.
Warning
!
Commissioned installation
The installation work should be done by
the after-sales service worker. Selfinstallation may cause water leakage,
electric shock and fire accident because of
improper installation.
It is strictly prohibited to rebuild the air
conditioner by yourself. Improper
rebuilding may cause fire, electric shock
and water leakage.
If abnormal conditions (sear smell) occur,
please stop the unit, turning off the electric
power and contact the after-sales service
center for solution.
If still using the unit under
this circumstance, the air
conditioner may be damaged
and may also cause electric
Cut off
power
shock or fire accidents.
When needing repair, please ask the after-
sales service work for help.
Improper maintenance and repair may
cause water leakage, electric shock and
fire.
During the unit operation,
do not insert fingers or other
articles alike into the air
inlet, outlet and louver.
Because the high-speed
fan is very dangerous,
it may cause hurt.
Ask after-sales service worker to take
measure to prevent refrigerant from
leaking.
If the leaked refrigerant exceeds a certain
density , it will cause lack of oxygen. If
the room installed with air conditioner
is too small, do take enough measure in
order to avoid lack of oxygen even if
refrigerant leaks.
When the air conditioner must be
dismantled and reinstalled, please ask
the after-sales service center to do this
work.
Improper installation may cause water
leakage, electric
shock and fire.
After a long-time using of the air
conditioner, please check if the
foundation of the unit is damaged.
If the foundation is damaged without
repair, the unit may fall
down leading to body hurt.
Any inflammable spray liquid cannot
be place or use near the air conditioner,
otherwise, fire
accident may happen.
Only after stopping the unit and cutting
off power can clean the air
conditioner to avoid
electric shock or injury.
1
Name of Parts
1
2
3
4
1
Air inlet
Air outlet
2
Air inlet
3
Repair panel
4
Note:
Do not block the air inlet and air outlet, otherwise the performance of the air
conditioner may be lowered.
2
Installation procedure
Install indoor unit
1.Choose installation place
The chosen installation place should meet the following requirements and
get the userís consent.
Place air can freely circulate.
>30cm
Place can perform level installation.
The condensate water can be drained smoothly.
Place where the noise and hot air will not
disturb the neighbors.
Place can ensure the space for successful
maintenance and repair.
>10cm
>10cm
>15cm
>60cm
Place where the four corners of the unit are easily installed and leaves
at least 1m height space.
Place where the wall hole is easy for drainage.
When installing multiple units, make sure to leave enough space to
avoid air short-circuit.
If the outdoor unit near the street, it should not be lower than 2.5m.
Please install in the place that can sufficiently bear the weight of the
unit. The air conditioner cannot install on a non-special metal frame
(e.g. theft guard net).
Install in the place with intensity as high as possible to prevent the
noise and vibration from spreading to other places.
Avoid the place where the strong airflow directly toward the air inlet
or air outlet.
Avoid the place where high frequency electromagnetic waves are
generated to prevent the communication of indoor and outdoor from
being affected.
Avoid the place where the combustible gas exists. The combustible
gas around the air conditioner may cause fire.
Avoid the place where the combustible gas may be leaked. If the leaked
gas gathers around the air conditioner, it may cause fire accident.
Avoid the place with to much oil, vapor and salinity, such as, seashore
and hotspring area and the area with sulfurated gas, etc. corrosive gas.
If install in these places, the air conditioner needs special maintenance.
Avoid the place where the heat source directly radiates or with other
heat sources.
3