Haier AU302CHBAA Installation Instructions Manual

AU302CHBAA
Name of parts ...................................................1
Safety precautions..........................................2-3
Installation diagram of indoor & outdoor unit....4
Installation tools...............................................5
Installation instruction......................................6
Installation of outdoor unit.................................7
Refrigerant.....................................................13
Electric wiring...........................................14-16
Setting in site.................................................17
Schedule of trouble .........................................18
CONTENTS
Before using the air conditioner, please read this manual carefully Please keep this manual properly for future use
Room air conditioner
OUTDOOR UNIT
INSTALLATION INSTRUCTIONS
No.0010575401
Name of parts
1
Air inlet
Air outlet
Air inlet
Servicing panel
2
1
3
4
Cut
power
off
2
Safety precautions
Please read the following safety precautions, and use the air conditioner correctly.
The following lists four kinds of safety precautions and recommendations: Warning: Improper use may cause death or serious injury, or other serious consequences. Notice: Improper use may cause body injury or unit damage; in some cases, it may cause serious consequences. : Any contents marked with this prohibition symbol are the actions must be prohibited.Otherwise, it may cause unit damage or endanger the body safety of user. Instruction:These contents are to confirm proper use of the unit.
The following safety precautions must be observed. These safety precautions should be kept in hand to consult it when needs. If the air conditioner is resold to a new customer, this manual also should be given to him.
If finding abnormal phenomenon(e.g. smell of fire), please cut the power immediately and contact our after-sale service staffs for the solvent.
In this case, if you still use the unit, it will be damaged and electric shock or fire accident may be caused.
When needing repairing, please contact our after-sale service staffs to do it.
Improper repair may cause water leakage, electric shock and fire accident.
During operation, do not put fingers or any other objects into the air inlet/outlet and swing plate.
Because the high-speed fan motor is very dangerous, it may cause body injury.
Warning
Please contact after-sale service staffs for the preventive measures for refrigerant leakage.
If the leaked refrigerant exceeds a certain density, it will cause anoxia. If the room equipped with air conditioner is very small, adequate measures must be taken to avoid anoxia accident even if refrigerant leaks.
When the air conditioner must be dismantled and reinstalled, please let the after-sale service staffs do the job.
Improper installation may cause water leakage, electric shock and fire accident.
Do not remove the air outlet of the outdoor unit. Exposure of the fan is very dangerous, it may cause body injury.
After the air conditioner has been used for a long time, it is necessary to check if the base of it damaged.
If the damaged base is not repaired, the unit may fall down to cause hurt.
Safety precautions
3
Warning
Do not step on or put articles on the outdoor unit assembly.
The overturn of person or articles from the unit may cause hurt.
Do not operate the unit with wet hands.
Otherwise, electric shock may occur.
Only the fuse of proper specification.
Do not use electric wire or any other material instead of fuse, otherwise, it may cause trouble or fire accident.
Do not put or use any flammable spray liquid near the air conditioner, otherwise, it may cause fire accident.
Only after turning off the air conditioner and cutting off the power can it be cleaned to avoid electric shock or body injury.
Do not use water to clean the air conditioner.
Otherwise, it may cause electric shock.
Connection of grounding wire.
The grounding wire should not connect with gas pipe, tap water pipe, lightning rod or telephone line. Improper grounding may cause electric shock accident.
Use the correct drain hose to ensure smooth drainage.
Improper drain hose may cause water leakage.
The air conditioner should not be installed in a place where have flammable gas.
The flammable gas near the air conditioner may cause fire accident.
A air breaker should be equipped.
If do not equip the air breaker, electric shock easily happen.
Installation diagram of indoor & outdoor unit
4
A
B 1
B 2
Outdoor unit
Gas pipe mm 12.7
L1 m Suggest 10m Max. :15m
Pipe length of one way L2 m Suggest 10m Max. :15m
L3 m Suggest 10m Max. :15m
Drop between indoor Indoor unit up m Suggest 5m Max. :10m
and outdoor unit Indoor unit down m Suggest 5m Max. :10m
No need to recharge: when piping length of one way is less than 5 meters.
Piping data.
L1
L3
L2
1
2
2
3
3
3
3
3
AS122XABAA
AS092XABAA
AS092XABAA
L1 means the piping length when the system only connects with one indoor unit.
L2, L3 means the piping length when the system connects with 2 indoor units.
Long piping length and large drop between indoor unit and outdoor unit will reduce the
performance capacity obviously.
1
2
3
Installation tools
Standard accessories
The following parts mentioned in this instruction is optional.
Mark
A B C D E F
1
4
1
3
1
,
Parts name
Adhesive tape
Pipe supporting plate
Connection pipe
Drain hose
Insulation material
Powder
Putty
Rubber cushion
Refrigerant oil
Col
d fro
nt
Plastic clamp
Shape, name
Quantity Remarks
The following are accessories attached with the unit, they can be used with the need of installation
Installation tools
5
1. Screw
2. Steel saw
3. Drill (70mm dia.)
4. Spanner [17, 27mm dia.]
5. Spanner [14, 17, 19, 27mm]
6. Pipe cutter
7. Flarer
8. Knife
9. Pliers
10. Leakage detector or soap water
11. Tape measure
12. Scraping knife
13. Refrigerant oil
14. Vacuum pump
15. Nitrogen tank
Big wire clamp