Haier AS71NE1HRE user guide manual

Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITION OPERATION MANUAL
0010582061
ER
AS26NC1HRA AS35NC1HRA AS53HE1HRA AS71NE1HRE
11
1
2
10
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
12
1
Display board A
Display board B
Signal receiver hole
COOL display
HEALTH display
4
4
2
2
3
3
1
Signal receiver hole
1
5
DRY display
TIMER ON/OFF display TIMER ON OFF display SLEEP display
6
Ambient temp.display
When receiving the remote control signal, display the set temperature.
Ambient temp.display
When receiving the remote control signal, display the set temperature.
2
3
5
6
4
HEAT display
Display board C
1
4
2
3
1
5
Operation mode indicator
(lights up when the compressor is on.)
Timer mode indicator
(Lights up whenTimer operation is selected.)
Power indicator
(Lights up when unit starts.)
Ambient temp display
When receiving the remote control signal, display the set temperature.
Remote signal receiver
(A beeping sound is generated when a signal from remote controller isreceived.)
1
1
2 3 4 5
2
4
3
Operation mode indicator
(lights up when the compressor is on.)
Parts and Functions
Indoor Unit Outdoor Unit
Remote controller
Outer side of the controller
OUTLET
CONNECTING PIPING AND ELECTRICAL WIRING
INLET DRAIN HOSE
1. FAN SPEED button Used to select fan speed: LOW, MED, HI, AUTO
2. SWING LEFT/RIGHT button
3. DRY button Used to set DRY operation.
4. HEAT button Used to set HEAT operation. (Cooling only unit do not have displays and functions related with heating.)
17
QUIET
C
E
2
13
14
15
16
ECO
T
U O
11
12
.
4
5. COOL button Used to set COOL operation.
6. QUIET button
7. Display of each function status
8. Operation mode display
9. Signal sending end device
10. Signal sending display
11. TEMP display
12. FAN SPEED display
Swing up/down display swing left/right display
13. TIMER ON display
TIMER OFF display CLOCK display
14. ON / OFF button
15. TEMP button
used to change setting temperature
16. SWING UP/DOWN
button
17. ECO button
power saving function
Outlet
Horizontal flap
Display board
(adjust up and down air flow Don't adjust it manually)
(adjust left and
ow)
Vertical blade
Emergency
Switch
right air fl
Inlet
Air Purifying Filter
(inside)
Inlet grille
Anion generator
(inside)
(inside)
Actual inlet grille may vary from the one shown in the manual according to the product purchased
2
Operation
Loading of the battery
Clock set
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder); Be sure that the loading is in line with the “+”/“-”;
Load the battery, then put on the cover again.
Press CLOCK button,
Press “+” or “-” to set correct time.
Each press will increase or decrease 1min. If the button is kept pressed, time will change quickly.
press CONFIRM, “AM” and
starts working.
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle
change-over wireless telephone is installed in the room,
signals,so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries. If the remote controller can’t run normally during operation, please remove the batteries and reload several minutes later.
Inner side of the controller
CHILD LOCK
SLEEPSMART
E
E
E FF
M
19
20
21
22
23
24
25
27
28
30
31
18
26
FRESH
LIGHT
10
QUIET
29
32
33
18. nottubEDOC Used to select CODE A or B with a press, A or B will be displayed on LCD. Please select A without special explanation.
19. TESER button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the controller normal.
20. nottubERIUQNI Inquire the external environmental temperature and the operating power of the machine. (e.g. when
the panel display “01”, the operating power is 100W; when the panel display “02”, the operating power is 200W, and so forth)
21. POWER button
22. LIGHT button Control the lightening and extinguishing of the indoor LED display board.
23. HEALTH AIRFLOW button
24. HEALTH button
25. SMART button Used to set SMART operation. (This function is unavailable on some models.)
26. SLEEP button
27. 10 ºC button special heating set function: 10 degree heating maintaining (valuable for RS)
28. CHILDLOCK button
If pressed, the other buttons will be disabled. Press it once again, lock will be cancelled.
29. FRESH button
30. TIMER ON / OFF button
31. HOUR button used to change clock or timer
32. CANCEL/CONFIRM button
clock settings.
33. CLOCK button
The following functions and related displays are not available:
20
Remove the battery cover;
1
2
3
1
2
3
QUIET
SMART
SLEEP
10
LIGHT
CHILD LOCK
FRESH
Hint:
Remove the batteries in case unit won’t be in usage for a long period. If there are any display after taking-out, just need to press reset key.
is
likely
in receiving the
3
QUIET Operation
COOL,HEAT and DRY Operation
QUIET Operation
Unit start.
Select operation mode.
Press the COOL button on
the remote control.
Press the HEAT button on the remote control.
Press the DRY button on the
You can use this function when silence is needed for rest or
reading.
For each press,
is displayed Air conditioner starts
POWER function operation. In SOFT operation mode, fan
speed automatically takes low speed of AUTO fan mode.
Press SOFT button again,
disappears, the operation
stops.
Operation
1. In DRY mode, when room temperature becomes
lower than temp. setting +2 ºC, unit will run
intermittently ai LOW speed regardless of FAN
setting.
2. Remote controller can memorize each operation
status. When starting it next time, just press ON/
OFF button and unit will run in previous status.
AM
QUIET
E
ECO
F
.
QUIET
QUIET
1
2
AM
QUIET
ECO
.
remote control.
DRED Operation
Haier Peaksmart enabled air-conditioners have a Demand Response Mode display
on the indoor unit.
The display could be labelled d1, d2, d3 (wording may differ model to model). These modes are described in more detail below:
odottahWnoitpircseDyalpsiDedoM
DRM3 d3
Your air conditioner will continue to cool or heat during the peak demand event. The energy consumed by your air conditioner is capped to 75%.
No action is required.
DRM2 d2
Your air conditioner will continue to cool or heat during the peak demand event. The energy consumed by your air conditioner is capped to 50%.
No action is required.
DRM1 d1
Your air conditioner is still turned on and the fan will continue to operate. Your compressor is turned off and cool/hot air will no longer be generated
DRM1 mode is only activated during emergency demand management situations. This mode will automatically reset the device within 2 hours .If your air con is in this mode for longer than 2 hours please contact Energex on 13 12 53.
(This function is unavailable on some models.)
4
Unit will start running to reach the temp. setting on LCD.
COOL/DRY:
For each press of “
” button, air
displays as follows according to different operation modes:
FAN Operation
LOW MED HI AUTO
Press FAN SPEED button. For each press, fan speed changes as follows:
Unit will run at selected fan speed.
Press TEMP button.
Every time the button is pressed, temp. setting increases 1 ºC. Every time the button is pressed, temp. setting decreases 1 ºC.
Operation
When humidity is high, condensate water might occur at air outlet if all vertical louvers are adjusted to left or right.
position for a long time in COOL or DRY mode, otherwise, condensate water might occur.
The water-ion generator in the
airconditioner can generate a lot
of anion effectively balance the
quantity of position and anion in
the air and also to kill bacteria
and speed up the dust sediment
air in the room.
and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the
grille will close automatically.
Notice:
Do not force the outlet grille by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller. Remote controller can memorize each operation status. when starting it next time, just press ON/OFF button and unit will run in previous status.
The setting of
function
The cancel of
function
Press HEALTH button
Press HEALTH button twice press and
the operation stops.
For each press,
is displayed
Air conditioner starts health anion
function operation.
Operation
When indoor fan motor is running, it has healthy process function. (It’s available under any mode) When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
HEALTH Operation HEALTH AIRFLOW Operation
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
QUIET
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
QUIET
appears on the display. Avoid
the body.
again,
appears on the display.
direct to the body.
Note:
2. In heating, it is better to select the mode.
3. In cooling, it is better to select the
mode.
4. In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille.
5. Select the appropriate fan direction according to the actual conditions.
5
Set Clock correctly before starting Timer operation. You can let unit start or stop automatically a following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
POWER Operation
When you need rapid cooling,
you can use this function.
Select your desired operation mode.
Time setting.
Remote controller: “
TIMER ON
Remote controller: “
TIMER OFF
ON
” or “
OFF
TIMER ON OFF / TIMER ON OFF
procedure in “Time setting for TIMER OFF”
Remote controller:
TIMER ON OFF
procedure in “Time setting for TIMER ON”
Remote controller:
TIMER ON OFF
Every time the button is pressed, time setting increases or decreases
Select your desired TIMER ON.
Select your desired TIMER OFF.
For each press,
is displayed Air conditioner
starts POWER function operation.
In COOL mode, fan speed automatically takes high
speed of AUTO fan mode.
Press POWER button again,
POWER
disappears, the
operation stops.
POWER Operation TIMER Operation
T
E
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
Hints:
During POWER operation, in rapid COOL mode, the room will show varying temperature distribution.
To cancel TIMER mode
Symbol clears from the screen
3
T
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
1
2
1 min, if kept depressed, it will increase rapidly. It can be adjusted within 24 hours.
Operation
6
7
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
3 hours then stop. Temp is lower than temp setting so that room temperature won’t be too high for your sleep.
Approx. 6hrs
Temp. setting
Decreases 2
º
C
Decreases 2
º
C
Unit stop
Rises 1
º
C
Rises 1
º
C
Rises 1
º
C
Temp. setting
In COOL, DRY mode
In HEAT mode
Unit stop
1 hr
1 hr
1 hr
3 hrs
3 hrs
1 hr
SLEEP operation starts
SLEEP operation starts
SLEEP
operation stops
SLEEP
operation stops
Press SLEEP button.
Operation Mode
1. In COOL, DRY mode
1 hours after SLEEP mode
starts, temp. will become 1 ºC
higher than temp. setting. After
another 1 hours, temp. rises by
1 ºC further. The unit will run for
further 6 hours then stop Temp.
is higher than temp. setting so
that room temperature won’t be
too low for your sleep.
2. In HEAT mode
1 hours after SLEEP mode starts, temp will become 2 ºC lower than temp. setting. After another 1 hours, temp decrease by 2 ºC further. After more another 3 hours, temp. rises by 1 ºC further. The unit will run for further
3. In SMART mode
The unit operates in corresponding sleep mode, which adapted to the automatically selected operation mode.
4. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted. When TIMER function is set, the quiet sleeping function can’t be set up. After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing­on, if the two modes are set up at the same time, either
automatically, and the other mode will be cancelled.
Power Failure Resume Function
not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running.
Note to the power failure resume:
enter function after hearing four sounds. And press the
this function after hearing two sounds.
Comfortable SLEEP
Operation
M
QUIET
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
8
(This function is unavailable on
some models)
One key can give you a
comfortable room!
The air conditioning unit can
judge the indoor temperature and
humidity
, and make the adjustment
accordingly.
SMART start
or SMART stops
Press ON/OFF button, unit starts.
Press SMART button “
” is
displayed on the remote controller.
Automatic adjusting with the environmental temperature, running with power saving.
Under the cooling, heating and dehumidifying mode, press the smart key to enter the smart function. Under the smart running mode, when the air conditioning is running, it will automatically select cooling, heating, dehumidifying or blowing mode as When the smart function is running, press the “cooling” “heating” or “dehumidifying” key to switch to the other mode, you will exit from the smart function.
The power saving function only works under the cooling, heating or dehumidifying mode, after the power saving function is set, press the sharp, mute, sleep, or smart key to exit the power saving function.
After the power saving is set, the host machine will automatically adjust the setting temperature, and automatically control the compressor,which may be inconsistent with the user’s setting.
The power saving function is more effective after the air conditioning has been running for a long time (more than 2 hours)
SMART FRESH SMART Defrost SMART FAN SPEED SMART FAN HEALTH SMART DRY SMART SOFT SMART Control temperature
SMART Operation ECO Operation
QUIET
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
M
EE
.
Press ECONOMY button “
ECO
” is
displayed on the remote controller,
unit will run in ECONOMY operation.
Press ECONOMY button
again, ECONOMY disappears,
the operation stops.
Operation
Exhaust the stale air from the room, and inhale fresh air .
(This function is unavailable on some models.)
Press FRESH button “
is displayed
on the remote controller and the change-
for-fresh-air function operation begins.
Note: Since this model has no fresh air
unit installed, there is no change for the
operating status.
For twice press , the display “
disappears and the change-for-fresh-
air function operation is canceled.
Press “HEALTH” button when operating in heating
pressing “HEALTH” button, it displays in green for 3 seconds, then red for 10 seconds, and green for 3 seconds, repeating this cycle. If you press “FRESH” button in heating or health operating mode, a purple display appears in addition to the above red and green display cycle; that is, purple for 3 seconds, red for 10 seconds, green for 3 seconds, purple for 3 seconds, red for 10 seconds, green for 3 seconds, repeating this cycle.
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the “Pi” sound is heard once, which means the start of this operation.
emergency operation starts, the unit will run automatically in the following modes:
Room
temperature
Designated
temperature
Timer mode
Fan
speed
Operation
mode
Above 24 ºC 24 ºC No AUTO COOL
Below 24 ºC 24 ºC No AUTO HEAT
It is impossible to change the settings of temp. and fan speed, It is also not possible to operate in timer or dry mode.
Test operation:
T
est operation switch is the same as emergency switch. Use this switch in the test operation when the room temperature is below 16 ºC, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds. After you hear the “Pi” sound twice,
Air Filter cleaning
1.
Open the inlet grille by pulling it upward
2.
downward.
3.
Use a vacuum cleaner to remove dust, or wash
completely in the shade.
4.
the “FRONT” indication is facing to the front. Make sure that the
the stopper. If the right and left
defects.
5.
Close the inlet grille
FRESH Operation
Emergency operation and test operation
For smart Use of The Air Conditioner
Operation
SMART
SLEEP
LIGHT
CHILD LOCK
FRESH
Note:
If the unit didn’t install change-for-fresh-air electrical
engine, change-for-fresh-air function is not available.
Pi
Pi Pi
Once every two weeks
9
Maintenance
Setting of proper room temperature
Close doors and windows during operation
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet or outlet
Proper
temperature
During cooling operation prevent the penetration of
direct sunlight with
curtain or blind
OFF
Remote Controller Indoor Body
1.Open the lnlet Grille
2.Detach the standard air filter
3.Attach Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
5.Close the Inlet Grille
Close the Grille firmly
Slide the knob slightly up
ward to
release the filter, then withdraw it.
Put air purifying filter appliances into the
right and left filter frames.
NOTE:
During the course of normal domestic use, the photocatalystair purifying filterwill require recharging. This can be done by simply exposing the filter to direct sunlight every 6 months.
Prop up the inlet grille by using a
small device named grille support
ATTENTION:
Please keep the bacteria-killing medium air purifying filter in
avoid long time directly sunshine
when you stop using it,or its ability of sterilization will
be
reduced.
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
which located in the right side of the indoor unit.
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
the cool and dry conditions
For Smart Use of The Air Conditioner
Replacement of Air Purifying Filter
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria killing medium air purifying filter face outside,and the white side face the unit.
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
wipe the air conditioner by using a soft and dry cloth.For serious stains,
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is
from the stopper, and remove the filter do
wnw
ard.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
ay
damage the coating of the unit.
Hot water over 40
O
C(104OF) may
discoloring or deformation.
Once every two weeks
m
cause
released
is
completely
and left filters are not
may cause defects.
Detach old Air Purifying Filter
10
the power supply cord and so on.
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
Cautions
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
Connect the earth cable.
earthing
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
1.Do not use power supply cord extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITED
PROHIBITED
PROHIBITED
PROHIBITED
Do not start or stop the
operation by disconnecting
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITED
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITED
PROHIBITED
PROHIBITED
PROHIBITED
PROHIBITED
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITED
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITED
PROHIBITED
PROHIBITED
STRICT ENFORCEMENT
Check proper installation of the drainage securely
WARNING
11
Trouble shooting
Normal Performance inspection
Noise is heard
Phenomenon
Cause or check points
The system
immediately.
Smells are generated.
Mist or steam are
Multiple
check
Poor cooling
When unit is stopped, it won't restart
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit
During unit operation or at stop, a swishing or gurgling noise may
(This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
temperature changes. Should there be a big noise from
filter may be too dirty.
This is because the system circulates smells from the interior
During COOL or DRY operation,
This is due to the sudden cooling
Is power plug inserted? Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before
Is temperature set correctly? Are there some doors or
Is there any direct sunlight through the window during the
Are there too much heat sources or too many people in the room
In dry mode,
fan speed can’t be changed.
In DRY mode, when room temperature
setting+2
o
C,unit will run
regardless of FAN setting.
during cooling operation?
cooling operation?(Use curtain)
windows left open?
inlet and outlet?
Normally it should be cleaned every 15 days.
intermittently at LOW speed
becomes lower than temp.
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture, paint, cigarettes.
air flow in unit operation, air
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
Cautions
3. If the fuse of indoor unit on PC board is it with the type of
T. 3.15A/ 250V
outdoor
broken,change it with the type of
T.25A/250V
The refrigerating circuit is leak-proo f.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following
situation
The power plug and connecting cable
acquired the local
2. If the power supply cord is damaged, it
must be replaced
manufacturer
qualified
person.
4. The wiring method should be in line with
the local wiring
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
7. The appliance is not intended for use persons
without supervision.
8. Young children should be supervised
with
the appliance.
9. Please employ the proper power plug,
cord.
11.In order to protect the units,please turn 30 seconds
later, cutting off the power.
10.
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
D.B
Maximum:D.B
D.B
Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32oC/23oC
24
o
C/18oC
o
C/-8oC
46
o
C/26oC
18
o
C
27
o
C
21
o
C/15oC
Outdoor
Maximum:D.B/W.B Minimum:D.B
24
o
C/18oC
-15
o
C
(INVERTER)
o
C
7
-
Minimum:
Minimum:
or its service agent or a similar
broken,please
. If the fuse of
standard.
by young children or
to ensure that th
ey
which fit into the
must have
off the A/C first,
Before asking for service, check the following first.
blown out.
does not restart
by the
change
unit is
infirm
do not play
p
ower supply
attestation.
and at least
15
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
swing louver.
This appliance is not intended for use by persons (including children) with reduced physiced, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of appliance by person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
grille of the air
or any other things into the
12
Loading...