Haier AF142XCEAA, AF122XCEAA, AF072XCEAA, AF092XCEAA User Manual

R
oom Air-conditioner indoor units
Console Type
OPERATION AND INSTALLATION MANUAL
AF072XCEAA AF092XCEAA AF122XCEAA AF142XCEAA
No.0010577698
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
Table of Contents
Cautions
Parts and Functions Operation hints
Trouble shooting
Installation Manual of Room Air Conditioner
1-4
5
6
7
8
9-14
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
child
can
damaged
Disposal of the packaging of your new air conditioner
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
All the packaging materials employed in package of your new air conditioner may disposed without any danger to the environment.
The cardboard box may be broken or cut smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
the
be
into
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items , crushing or twisting any tubes , or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes , it may result in serious eye injuries.
1
Cautions
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Rated Maximum Minimum 27 32 18
DB C
19 23 14
WB C DB C
35 43 10
WB C
24 26 6 20 27 15
DB C
14.5 -- --
WB C
7 24 -7
DB C
6 18 --
WB C
Cooling
Heating
Indoor outdoor
Indoor
outdoor
6. The appliance is not intended for use by young children or infirm persons without supervision.
7. Young children should be supervised to ensure that they do not play with the applience.
8. A breaker should be used in the circuits, which should be all-pole cutoff and the distance between its two contacts should be not at least 3mm .
9.The power plug and connecting cable must have acquired the local attestation.
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T3.15A/250V AC.
4. The wiring method should be in line with the local wiring standard.
5. The waste battery should be disposed properly.
2
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
Installation in an inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth cable.
STRICT
ENFORCEMENT
Use fuse with specified capacity. Replacement with steel or copper wires are absolutely prohibited.
STEEL WIRE
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
PROHIBITION PROHIBITION
FUSE
COPPERWIRE
Do not get the unit exposed to vapor or oil steam.
Grounding wire should not be connected to that of gas pipeline, water pipeline,lighting arrester or telephone.
Check proper installation of the drainage securely
STRICT
ENFORCEMENT
3
Cautions
Use of Air Conditioner
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker.
OFF
Connect power supply cord to the outlet completely.
STRICT ENFORCEMENT
Do not use power supply cord in a bundle.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding , or cultivation.
STRICT ENFORCEMENT
After installed, the unit shall be tested for electric leakage.
STRICT ENFORCEMENT
Take care not to damage the power supply cord.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not use power supply cord extended or connected in halfway.
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Do not place animals or plants in the direct path of the air flow.
PROHIBITION
STRICT ENFORCEMENT
Check good condition of the installation stand.
PROHIBITIONPROHIBITION
Do not place any objects on or climb on the unit.
4
PROHIBITION
Do not pour water onto the unit for cleaning.
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITIONPROHIBITION
Parts and Functions
Indoor unit
1 2
3
4
5
1.OUTLET
2.CONTROL PANEL
3.INLET
4.FILTER ( inside )
5.OUTLET
5
Operation hints
than
Power failure resume (please set and apply as necessary)
With setting of power failure resume, if sudden power failure occurs, the unit will resume original operation when power is supplied again.
Setting method:
with ON of remote controller (except TIMER and FAN),repeatedly press SLEEP button 10 times in 5 seconds,after 4 Beep from the buzzer,the unit comes into power failure resume mode.
To cancel:
press SLEEP button continuously 10times in 5 seconds,the buzzer sounds Beep twice and power failure resume function is canceled.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFFto turn off the unit when power resumes.
used
6
Maintenance
Cleaning of the unit
Turn off the power switch
Take off the air inlet grill
First switch off the power supply,take off the screw cap,loosen the screw with cross screwdriver .
Clean the filter
Use water or vacuum cleaner to remove dust. If it is too dirt, clean with detergent or neutral soap water. Rinsing with fresh water, dry the filter and re-assemble.
Caution:
Do not wash filter in hot water above 40∞C, which will damage the filter. Do carefully wipe the filter.
Clean the indoor(outdoor) unit
Clean with warm cloth or neutral detergent, then wipe away moisture with dry cloth. Do not use too hot water(above 40∞C),which will cause discoloration or deformation. Do not use pesticide or other chemical detergents.
Do not touch with wet hand
Do not clean with hot water or solvent
Maintenance at the end of application season
On a fine day, unit shall be started and operate in FAN mode for about half a day until the inside of the unit becomes thoroughly dry.
Turn off the unit operation switch and power on/off. Otherwise,there will be some electricity consumption even the unit is in stop status.
Clean the filter and indoor,cover the units well.
Maintenance before beginning of application season
Check there are no obstacles in the air inlet and outlet to avoid impairing of working efficiency.
Please do attach the air filter to ensure the
electrostatic filters not soiled.Otherwise,dirt
will come into and damage the unit or bring
failures.
7
Trouble shooting
Before asking for service, check the following first.
Cause or check pointsPhenomenon
Normal Performance inspection
The system does not restart immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
When unit is stopped, it won't restart immediately until 3 minutes have elasped to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Multiple check
Does not work at all.
Poor cooling
Is power plug inserted? Is there a power failure? Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain)
Are there too much heat sources or too many
people in the room during cooling operation?
8
Installation Manual of Room Air Conditioner
more than
more than
more than
more than
Fig1
330
617
Fig2
Fig3
Tool necessary
1. Screw driver
2. Hacksaw
3. 70mm dia.hole core drill
4. Spanner(dia. 17,27mm)
5. Spanner(14,17,27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
Installation of indoor unit
selection of installation place
Place where it is easy to route drainage pipe and outdoor piping. Place ,away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evently to every corner of the room. Place near power supply socket.Leave enough space around the unit. Place ,robust not causing vibration,where the body can be supported sufficiently. To prevent interference, place it at least 1m away from other electric machines, such as TV set, radio. Installing According to the dimension of the figure 2 shown, nail two cement steel nails on the wall,Keep 2~3 mm out.then hang the back of the unit on them. There must be no gap between the indoor unit and wall. Remove the front panel,then use two expansible screws to fix the unit on the floor.As figure 3 shown. Once refrigerant piping and drain piping connections are complete,fill the gap of the throght hole with putty. Attach the front panel and front grille in their orginal positions once all connections are complete.
9
Installation Manual of Room Air Conditioner
Fixing of the unit
1. Position of the wall hole
Wall hole should be decided according to installation place and piping direction.(refer to installation drawings).
2. Making a wall hole
Drill a hole of 120X70mm dia. with a little slope towards outside.
3. Piping connection
(1)
Schematic diagram for unit connection
Flared pipe connection
3-way Valve
Indoor unit
Indoor unit
(2)
Connection pipe dimensions:
Indoor side
2-way Valve
Wall hole
70mm
(Cross section of wall hole)
Outdoor uint
Outdoor side
Thickness of wall
Pipe Value
Liquid
Gas
6.35mm
9.52mm
Torque
18 N.m
50 N.m
Apply and tighten the nut.
(3)Cautions for pipe connection
Spanner
Pipes free from twists, deformation, water, dust. Dedicated tools for each R407C and R410A should be used and stored separately. Optimized radii of bends
Double-spanner operation
Spanner
Insulation to be applied on all gaseous pipes Flared section free from cracks
Threads on the pipes may be damaged when tightening if the pipes are not well aligned.
(4)
Pipe connection process
Apply refrigeration oil on the end of the pipe to be connected and on the flared section. Align the pipes to be connected and tighten the nut. (See the figure) Ensure that no foreign articles enter into the pipes.
Joint
Nut
10
Installation Manual of Room Air Conditioner
Piping connection of the indoor unit
1. Arrangement of piping and drainage pipe After opening inlet grill,you will see a control box. Remove the cover before working.
Cut away, with a hammer or a saw, the lid for piping according to piping direction.
Insulation material
Drain hose
Copper tube
Connecting electric cable for indoor and outdoor unit
According to the piping method, connect the piping on indoor unit with union of connection pipe. Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape. Insert the bound piping connecting electric cable and drain hoes through wall hole to connect with outdoor unit.
2. Arrangement drain hose Drain hose shall be placed in under place. There should be a slope when arrange drain hose. Avoid up and down waves in drain hose. If humidity is high, drain pipe(especially in room and indoor unit) must be covered with installation material.
11
Installation Manual of Room Air Conditioner
Electric wiring :
Process of wire connections
1. Loop terminal After removing the screw, fix the wire ring on the screw, reinsert the screw into the block terminal and then tighten the screw.
2. Straight terminal After loosening the screw, inset the wire end into the block terminal and then tighten the screw. Slightly pull the wire to see if it is tightly fixed.
3. Wire capping After completion of connection, capping clips must be applied on the external sleeve of the wires.
Wiring of indoor unit
Wiring diagram of loop terminals
Remove air intake screen and take out the front wires.
Connect the wires as specified in the above methods and diagrams for indoor unit and wire con­ nections.
Properly apply capping clips on the wires.
Replace the air intake screen.
Do not link the connecting and signal wire with the same cable, a snug space must be maintained between connecting and signal wires.
Shield of the signal wire should be spot grounded.
1(L)
Block terminal
Capping clip
Wiring connection:
N
L
TO POWER SUPPLY (1PH,220-230V~,50Hz)
Note:
When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks. Terminals of same number and same color shall be connected by the same wire. Incorrect wiring may damage air conditioner's control or cause operation failure.
P
Q
CONNECT TO OUTDOOR UNIT
12
Installation Manual of Room Air Conditioner
Others
1.Power supply requirements:
Voltage: single-phase1PH,220-230V*,50Hz Dedicated electrical cable should be installed by a qualified technician in
accordance with the state regulation for electrical engineering. The power source must be grounded.
A circuit breaker must be installed Electrical cables should be connected by ìYî method. Damaged or wornelectrical cable
must be replaced by authorized after sales agents.
The power plug should be connected as follows: L for live line, N for neutral line and for grounding.
Connection parameters: H05RN-F 3G(1.0-1.5)mm
Signal parameters: The signal wire must be shielded wire.
Cables for power supply, connection and signals are prepared by the owner.
2.Piping cutting and flaring
Be sure to carry out deburring after cutting with a pipe cutter. Insert flaring tool to make a flare.
H05RN-F 2x(0.75-1.5)mm
(Shieded wire)
A
Correct Incorrect
Installation inspection and test run: Please operate unit according to this Manual. Items to be checked during test run. Please made a '' '' in '' ''
Are there any gas leakage? How is insulation at piping connection carried out? Are electric wires of indoor and outdoor unit firmly inserted into terminal block? Is electric wiring of indoor and outdoor securely fixed? Is drainage securely carried out? Is earth line(grounding) securely connected? Is power supply voltage abided by the code? Is there any noise? Is control display normal? Is cooling operation normal? Is room temp. regulator normal?
Flare tooling die
Lean
Damage of flare Crack Partial Too outside
Liquid pipe Gas pipe
Pipe diameter Size A (mm)
6.35mm(1/4")
9.52mm(3/8")
0.8 ~1.5
1.0 ~1.5
13
Resumable failures are marked with " ", the others are not resumable failures. Resumable failure will disappear when the failure is eliminated and its failure code will disappear automatically within 30 seconds. But the other failure code will disappear only after the unit starts up once again. When failure occurs, the unit only can receive "OFF" signal from the controller. And when the unit is shut off, the failure code will disappear.
Failure description
Room temp. sensor abnormal Indoor coil temp. sensor abnormal (liquid pipe) Refrigerant system abnormal High pressure abnormal (outdoor) Drainage abnormal Communication between indoor and wired controller Indoor fan motor abnormalup Indoor fan motor abnormaldown 3 phase abnormal Low pressure abnormal (outdoor) Communication between indoor and outdoor abnormal Compressor overheat
CT current abnormal Outdoor ambient temp. sensor abnormal Outdoor coil pipe temp. Sensor A abnormal
Outdoor discharging temp. sensor B abnormal
Flash times of indoor receiver board
Power LED flashes 1 time Power LED flashes 2 times Power LED flashes 3 times
Power LED flashes 5 times Power LED flashes 6 times
Power LED flashes 7 times Power LED flashes 8 times Power LED flashes 9 times Running LED flashes once
Running LED flashes twice Running LED flashes 3 times
Running LED flashes 4 times Running LED flashes 5 times Running LED flashes 6 times Running LED flashes 7 times
Running LED flashes 8 times
Outdoor coil pipe temp. sensor B abnormal Abnormal modes running Outdoor discharging temp. sensor A abnormal Indoor EEPROM abnormal
14
Running LED flashes 10 times Running LED flashes 11 times Running LED flashes 12 times
Running LE
D flashes 14 times
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P.R.C Web Site: http://www.haier.com