Haier AF072XCBAA, AF142XCBAA, AF092XCBAA, AF122XCBAA Operation And Installation Manual

AF072XCBAA AF092XCBAA AF122XCBAA AF142XCBAA
Console Type
No.0010573520 E
Cautions..................................................1-4
Parts and Funct
ions
Operation.......... ........ ........ .................... 9-14
Maintenance.....................................
...15
Trouble shooting.............................
Installation Manual of Room Air Conditioner
17-22
CONTENTS
Before using the air conditioner, please read t his manual carefully. Please keep t his manual properl y for future use.
....16
R
oom Air-conditioner indoor units
OPERATIONAND INSTALLATION MANUAL
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of
child
entrapment. It must be noticed that air conditioner
system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner
can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get
damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in
the
package of your new air conditioner may
be disposed without any danger to the environment.
The cardboard box may be broken or cut
into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items , crushing or twisting any tubes , or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes , it may result in serious eye injuries.
Cautions
2
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.
4. The wiring method should be in line with the local wiring standard.
5. The waste battery should be disposed properly.
6. The appliance is not intended for use by young children or infirm persons without supervision.
7. Young children should be supervised to ensure that they do not play with the applience.
8. A breaker should be used in the circuits, which should be all-pole cutoff and the distance between its two contacts should be not at least 3mm .
9.The power plug and connecting cable must have acquired the local attestation.
The machine is adaptive in following situation
Cautions
Cooling
Heating
Indoor outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
3
Cautions
Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Safety Instruction
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
CAUTION
Installation in an inadequate place may cause accidents. Do not install in the following place.
Connect the earth cable.
PROHIBITION PROHIBITION
STRICT
ENFORCEMENT
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
Use fuse with specified capacity. Replacement with steel or copper wires are absolutely prohibited.
Grounding wire should not be connected to that of gas pipeline, water pipeline,lighting arrester or telephone.
FUSE
STEEL WIRE
COPPERWIRE
STRICT
ENFORCEMENT
Use of Air Conditioner
Cautions
STRICT ENFORCEMENT
4
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Connect power supply cord to the outlet completely.
After installed, the unit shall be tested for electric leakage.
Take care not to damage the power supply cord.
Do not use power supply cord in a bundle.
Do not use power supply cord extended or connected in halfway.
Do not insert objects into the air inlet or outlet.
Do not try to repair or reconstruct by yourself.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
OFF
STRICT ENFORCEMENT
STRICT ENFORCEMENT
Use an exclusive power source with a circuit breaker.
CAUTION
Do not use for the purpose of storage of food, art work, precise equipment, breeding , or cultivation.
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not operate the switch with wet hand.
Do not pour water onto the unit for cleaning.
Check good condition of the installation stand.
Do not install the unit near a fireplace or other heating apparatus.
Do not place animals or plants in the direct path of the air flow.
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
PROHIBITIONPROHIBITION
PROHIBITIONPROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
STRICT ENFORCEMENT
WARNING
Do not channel the air flow directly at people, especially at infants or the aged.
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
5
Parts and Functions
1
3
4
5
2
1.OUTLET
2.CONTROL PANEL
3.INLET
4.FILTER ( inside )
5.OUTLET
Remote controller
Indoor unit
FRESH
HIGH/SO
TIMER
SET
FILTER
B
A
M D
HEALTH
RESET
LOCK
SLEEP
FAN
TEMP
ON
OFF
SWING
MODE
CLOCK
CODE
LIGHT
OFF
A U T O
HEAT
Parts and Functions
CAUTION
Before opening the front grille, be sure to stop the operation and turn the breaker OFF. Do not touch the metal parts on the inside of the indoor unit, as it may result in injury.
ON/OFF button
Push once to start operation, push once again to stop it. Operation is set to AUTO, air flow is set to AUTO FAN. (page 9) Use when remote controller is not available.
Receiver
Signals are received from the remote controller here. Upon receiving a signal, there is a receiving sound.
Air outlet selection switch
This setting blows air from upper outlet only.
This setting automatically decides a blow pattern depending on mode and conditions.
This setting is recommended.
The unit is shipped from the factory with this setting.
Air outlet selection
Room temperature sensor
Senses the air temperature around the unit.
6
Loading...
+ 16 hidden pages