Haier AD18MS1ERA, AD24MS2ERAD, AD12MS1ERAD, AD24MS2ERA, AD28MS2ERA Operating Manual And Instructions

...
No.0150513771 E
Polski
AD24MS1ERA AD24MS1ERA(D)
AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD12MS1ERA AD12MS1ERA(D)
AD18MS1ERA AD18MS1ERA(D) AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D)
DUCT TYPE AIR CONDITIONER OPERATION MANUAL AND INSTALLATION MANUAL
Contents
Please read this manual carefully before installation.
Keep this operation manual for future reference.
English
Cautions Safety Precautions Parts and Functions Operation Installation Manual For Wire Controller Heating Mode Care and Maintenance Troubleshooting Precaution for Installation Is The Unit Installed Correctly Installation Procedure
3 4
7 10 14 15 16 17 20 21 22
AD24MS1ERA AD24MS1ERA(D)
AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD12MS1ERA AD12MS1ERA(D)
AD18MS1ERA AD18MS1ERA(D) AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D)
CE
All the products are in conformity with the following European provision:
-Low voltage Directive
-Electomagnetic CompatibilitY
ROHS
Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste.Do not try to dismantle the system yourself:the dismantling of the air conditioning system,treatment of the refrigerant,of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation.Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery.By ensuring this product is disposed of correctly,you will help to prevent potential negative cons­equences for the environment and humen health.Please contact the installer or local authority for more information. Battery must be removed from the remote controller and dis­posed of separately in accordance with relevant local and nationl legislation.
The products are fulfilled with the requirements in the council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment(EU RoHS Directive)
WEEE
In accordance with the directive 2012/19/EU of the European parliament,herewith we inform the consumer about the dis­posal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Contains fluorinatedgreenhouse gases
covered by the Kyoto Protocol
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.Do not vent into the atmosphere. Refrigerant type:R410A
GWP=global warming potential Please fill in with indelible ink,
1 the factory refrigerant charge of the product 2 the additional refrigerant amount charged in the field
and
1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label muset be adhered in the proximity of the
product charging port(e.g.onto the inside of the stop value
cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol
B fatory refrigerant charge of the product:see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
Haier Industrial Park, No.1 Haier road, Qingdao,P.R.China
A
B
C
D
kg
kg
kg
R410A
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
The appliances are not intended to be operated by means of an external timer or separate remote-control system. Keep the appliance and its cord out of reach of children less than 8 years.
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
IMPORTANT INFORMATION REGA­RDING THE REFRIGERANT USED
2011/65/EU
directive of the European parliament and of
GWP:2088
3
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
This appliance is not intended for use by persons (including children) with reducedphysical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
4
Safety Precautions
Before starting to use the system, read carefully this "SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety. Symbols which appear frequently in the text have following meanings.
Strictly prohibited.
Observe instructions faithfully.
Provide a positive grounding.
When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.
CAUTIONS FOR INSTALLATION
ON
OFF
WARNING
CAUTION
The system should be applied to places as office, restaurant, residence and the like.
The system should be installed by your dealer or a professional installer.
When you need some optional devices such as a humidifier, electric heater, etc., be sure to use the products which are recommended by us. These devices should be attached by a professional installer.
Application to inferior environment such as an engineering shop, could cause equipment malfunction and serious injury or death.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
Do not install nearby the place where may have leakage of flammable gas.
Depending on the place of installation, a circuit breaker may be necessary.
Drain pipe should be arranged to provide a positive draining.
If the gas leakes and gathers around, it may cause the fire.
Unless the circuit breaker is installed, it could cause elecrical shocks.
Where strong winds may prevail, the system should be fixed securely to prevent a collapse.
Install on the place where can endure the weight of air conditioner.
Make sure the system is grounded.
If the pipe is arranged improperly, furniture or the likes may be damaged by leaked water.
Bodily injury could result by a collapse. Bodily injury could result by a careless installation. Grounding cable should never be connected to
a gas pipe, city water pipe, lightning conductor rod or grounding cable of telephone. If the grounding cable is not set properly, it could cause electric shocks.
WARNING
CAUTIONS FOR TRANSFER OR REPAIR
Modification of the system is strictly prohibited. When the system needs a repair, consult your dealer.
When the air conditioner is relocated, contact your dealer or a professional installer.
Improper practice of repair could cause water leakage, electric shock or fire.
Improper practice of installation could cause water leakage, electric shock or fire.
Do not wash the air conditioner with water.
Do not install the system where the air outlet reaches directly the flora and fauna.
Make sure to use a fuse of proper electric rating.
Do not operate the system while the air outlet grill is removed.
It is strictly prohibited to place a container of combustible gas or liquid near the air conditioner or to spray it directly with the gas or liquid.
Neither stand on the air conditioner nor place something on it.
Do not use the power switch to turn on or off the system.
Do not touch the air outlet section while the swing louver is operating.
Do not use such equipment as a water heater, etc. around the indoor unit or the wire controller.
ON
OFF
It could cause electric shocks. It will not be good for their health. Use of steel or copper wire in place of a fuse is
strictly prohibited because it could result in a trouble or fire accident.
There is a risk of injury.It could cause a fire accident.There are risks of falling or injury by collapsed
object.
It could cause a fire or water leakage. There is a risk of injury. If the system is operated at the vicinity of such
equipment which generates steam, condensed water may drip during cooling operation or it could cause a fault current or short-circuit.
When operating the system simultaneously with a combustion apparatus, indoor air must be ventilated frequently.
Check occasionally the support structure of the unit for any damage after a use of long period of time.
Insufficient ventilation could cause an oxygen deficiency accident.
If the structure is not repaired immediately, the unit could topple down to cause a personal injury.
When cleaning the system, stop the operation and turn off the power switch.
Do not put water containers on the unit such as a flower vase, etc.
Cleaning should never be done while the internal fans are running with high speed.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
WARNING
CAUTION
CAUTIONS FOR OPERATION
You should refrain from exposing your body directly to cool wind for a long time.
Do not poke the air inlet or outlet with a bar, etc. When any abnormal condition (scorching smell or
others) is found, stop the operation immediately and turn off the power switch. Then consult your dealer.
It could affect your physical condition or cause some health problems.
Since the internal fan is operating with a high speed, it could cause an injury.
If you continue the operation without removing the cause, it could result in a trouble, electric shock or fire.
The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision devices or work of art.
Do not handle switches with a wet hand. Combustion apparatus should not be placed
allowing a direct exposure to wind of air conditioner.
Incomplete combustion could occur on the apparatus.
It could cause electric shocks.It could cause deterioration of food or other
problems.
5
Safety Precautions
6
Safety Precautions
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Cooling
Heating
Indoor temperature
Outdoor temperature
Indoor temperature
Outdoor temperature
max. DB/WB min. DB/WB
max. DB/WB min. DB/WB
max. DB/WB min. DB/WB
max. DB/WB min. DB/WB
32/23 C 18/14 C
46/26 C 10/6 C
27 C 15 C
24/18 C
-15 C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on the indoor PC board is broken please change it with the type of T 6.3A /250VAC(For series 24,28,36,48).
4. The wiring method should be in line with the local wiring standard.
5. The power cable should be: H05RN-F 3G 4.0mm2(For series 12,18,24); The connecting cable should be: H05RN-F 4G 1.3mm2 (For series 12,18,24,28,36,48) All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
6. The power cable and connect cable should be self-provided.
7. The breaker of the air conditioner should be all-pole switch, and the distance between its two contacts should be no less than 3mm.
8. The indoor unit installation height is at least 2.5m.
9. A leakage breaker must be installed.
10.For AD12MS1ERA and AD12MS1ERA(D),AD18MS1ERA,AD18MS1ERA(D), AD24MS2ERA,AD24MS2ERA(D), AD28MS2ERA(S),AD28MS2ERA(S)(D),we can get the 4 different ESP through adjust the indoor unit PCB SW1-4 and SW1-5, please refer below:
Attention: cut off the power supply to adjust the SW1-4, and SW1-5, or else the operation is invalid.
SW1
(1) (2) (3) (4) (5) (6) (7) (8)
Static pressure
10 Pa 30 Pa
50 Pa 70 Pa
OFFOFF OFFON ON OFF ON ON
- - - - - -
- - - - - -
- - - - - -
- - - - - -
Attention:
Unit model with the letter D is the mechine without water pump. Unit model without the letter D is the mechine with water pump.
AD12MS1ERA AD12MS1ERA(D)
AD24MS1ERA
AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD24MS1ERA(D)
7
Parts and Functions
Electrical components Case
Drain pan Evaporator
Air outlet frame
The pump drain opening
Electrical components Case
Air outlet frame
Drain pan Evaporator
The pump drain opening
Air outlet
Air inlet
Duct
The pump drain opening
Electrical components Case
Drain pan
Evaporator
Air outlet frame
Electrical components Case
Drain pan Evaporator
Air outlet frame
Drain opening
Electrical components Case
Air outlet frame
Drain pan Evaporator
Drain opening
Drain opening
Electrical components Case
Drain pan Evaporator
Air outlet frame
AD18MS1ERA AD24MS2ERA AD28MS2ERA(S) AD18MS1ERA(D) AD24MS2ERA(D) AD28MS2ERA(S)(D)
8
Parts and Functions
Buttons of the wire controller
Reset key
When in abnormal state, push the reset key with a spike, which may return the unit to normal
Health switch
Used to control oxygen function and negative ion
Filter reset
After cleaning air inlet and filter, press this switch. The unit begins to run
ON/OFF switch
Do on and off function. The unit is on when pressing it; and is off when pressing it again.
Fan speed switch
Change wind speed
Time switch
It is used to regulate setting time.
Self-inspection switch
It is used for inspection service
Air change switch
It is used to open and close air change function. The mode is as follows: No display-air change (automatic)­air change (RECOVERY)-air change (NORMAL)
Clock, timing and address setting
Timing switch
It is used for choosing timing running
Mode switch
Choose running mode
Swing switch
Open and close air flap
TEMP switch
Used for changing set temperature
AUTO
FAN ONLY
COOL
DRY
HEAT
TES
FAN
AUTO HIGH
LOW
FIX
CENTRAL
OPERATION
STANDBY PRE-HEAT
DEFROST
FILTER
MODE
HEALTH
SWING
CHECK
UNIT NO.
C F
DEMAND
CEN. ADD.
SYS. ADD.
MANUAL
ROOM TEMP.
SET TEMP.
TIMER
VENTILATION
CLOCK UP DOWN
ON
OFF
DAILY
AUTO
RECOVERY
NORMAL
MODE FAN SWING
HEALTH
CLOCK
TIMER
CHECK FILTER
RESET
ON/OFF
SET RECOVERY
TEMP
TIME
MED
9
Parts and Functions
Standby display
When the unit is on power and in "abnormity mode", or outdoor unit malfunction show alarm , "standby" is shown to reflect no need to unit.
Display of the wire controller
Remarks
The models in the manual don't have health, filter reset and Air change function.
Running mode display
Show the selected mode
Wind swing display
Filter screen warning sign
When the sign is shown, please clean the filter screen
Centralized display
When controlled by centralized controller, and chosen by "centralize or lock" mode, this information is shown.
Timing operation display
Show timing operation content
Temperature display
Display the room temperature, setting temperature, and unit number
Air volume display
Display the setting speed
Inspection status display
Air change display
Health function display
Unit number display Centralized adress display System adress display
Running display
When the compressor runs, it displays.
Demand display
When forced to run,"DEMAND" will be displayed , or show HH/LL in the temperature zone.
"Defrost" is shown when defrosting.
When in preheating status, "preheating" is shown.
AUTO
FAN ONLY
COOL
DRY
HEAT
TES
FAN
AUTO
HIGH
LOW
FIX
CENTRAL
OPERATION
STANDBY PRE-HEAT
DEFROST
FILTER
MODE
HEALTH
SWING
CHECK
UNIT NO.
C F
DEMAND
CEN. ADD.
SYS. ADD.
MANUAL
ROOM TEMP.
SET TEMP.
TIMER
VENTILATION
CLOCK UP DOWN
ON
OFF
DAILY
AUTO
RECOVERY
NORMAL
MODE FAN SWING
HEALTH
CLOCK
TIMER
CHECK FILTER
RESET
ON/OFF
SET RECOVERY
TEMP
TIME
MED
10
Operation
ON/OFF operation
Press ON/OFF switch on line controller directly
The line controller displays the running state in the latest time (timing and swing state may not be displayed).
1. Press "ON/OFF" switch.
The air conditioner starts operating, and the light on the wired controller is on.
3.Press "TEMP" switch
Change set temperature:press TEMP or TEMP every time, [SET] will display,and set temperature will increase/reduce
4.Press "FAN SPEED" switch
FAN ONLY Operation: Press "FAN SPEED" switch to change to "HIGH"--"MED"--"LOW"--"HIGH"
In AUTO,COOL,DRY,HEAT Operation: Press "FAN SPEED" switch to change to "AUTO"--"HIGH"--"MED"--"LOW"--"AUTO"
Avoid pressing "ON/OFF" switch frequently. Do not press line controller or switches by sharp objects. The temperature is on the basis of the setting value. The wind temperature may not reach the setting value because of the outer air conditioner and system protection. When the wired controller is power on, the screen fully displays it for two seconds. and clock zone "8888"-"888"-"88"-"8" flicker for 30 seconds. All the switches are invalid at the time.
Remarks
Note
5.Press "swing" switch on the line controller to swing the wind screen.
6.Press "ON/OFF"switch, off.
The light on the line controller is off.
2.Choose operation mode.
Press "mode"switch to change to "AUTO"---"FAN ONLY"---"COOL"---"DRY"---"HEAT".
HIGH
C
ROOM TEMP.
COOL
FAN
OPERATION
MODE
CLOCK
MODE FAN SWING
HEALTH
CLOCK
TIMER
CHECK FILTER
RESET
ON/OFF
SET RECOVERY
TEMP
TIME
2
4
5
3
1
6
Several seconds after the operation of the line controller, the setting of the unit will change.
11
Operation
1.Press "CLOCK" switch
2.Press " " and " " to regulate the time.
Setting of power failure compensation function
When SW1-6 on PCB of wire controller is OFF, it will be in power failure compensation. If the SW1-6 is ON, it has no compensation function. When the power is on after blackout, the unit will return to the former state if compensation function is set. Otherwise, it will stop. When restarting the unit, press "ON/OFF" switch on wired controller.
3.Press "setting" switch. The setting is achieved.
"CLOCK" flickers, and the time displayed is the real time.
The time increases a minute each time you press " " switch. The time decreases a minute each time you press " " switch.
If not in timing, the screen displays the real time. If in timing, the screen displays the timing time. If you want to know the real time, go to the first step.
Notes
The timing is based on the real time. Thus, the real time should be regulated in advance.
The clock regulation steps are as follows:
123
HIGH
C
ROOM TEMP.
HEAT
FAN
OPERATION
MODE
CLOCK UP
MODE FAN SWING
HEALTH
CLOCK
TIMER
CHECK FILTER
RESET
ON/OFF
SET RECOVERY
TEMP
TIME
Present time setting
12
Operation
2.Set up "TIMER"
The display changes with the following sequence:
on OFF
OFF
CYCLE
ON
no display
1.Press "TIME" switch.
The shorter setting time will be carried out firstly. If the ON timing and OFF timing are the same, the setting is invalid. Even in timing condition, you may start or close the unit through pressing "ON/OFF" switch.
Notes
Timing setting
Press "ON/OFF" switch firstly, and set up operation mode. Please regulate the clock in advance before using the timing function.
3.Time setting is achieved. Press"setting"switch.
If you want to change the timing mode to normal operation, press "timing" until there is no timing display. When the timing is invalid, the mode is in normal operation.
Cancel timing
1.The unit starts or stops at the setting time. Meanwhile, it displays the timing time.
2."ON Timing, OFF timing and circulation"means that the unit is on and off at the setting time everyday.
When timing ON or timing OFF flickers, press " " or " " to regulate the time Press" "or " "set up ON/OFF time. The setting time increases ten minutes each time you press " " switch. The setting time decreases ten minutes each time you press " " switch. When setting timing ON and timing OFF at the same time, press "timing" switch to change the setting item.
on OFF
HIGH
C
ROOM TEMP.
123
COOL
FAN
OPERATION
MODE
TIMER
ON
MODE FAN SWING
HEALTH
CLOCK
TIMER
CHECK FILTER
RESET
ON/OFF
SET RECOVERY
TEMP
TIME
OFF timing: when a set time has elapsed, the unit stops running. ON timing: when a set time has elapsed, the unit starts.
parts of wired controller explanation :
1. Switches or jumper wire must be adjusted when the wire controller is powered off. If the wire controller is powered on, the above operations will be invalid.
2. Function difference between master wire controller and slave one:
Notes
Factory Setting OFF default settingSW1-8
Installation Manual For Wire Controller
Factory Seting ON default settingSW1-7
13
Operation
Query indoor malfunction history:
In the state of power on or power off, press [CHECK] button, enter the malfunction-querying mode of all indoor units in the group. Then [CHECK] and [UNIT NO.] will display, and the actual indoor numbers will be displayed in some sequence (unit number is in decimals). At the same time, in the time region, there will be the current malfunction and the latest time malfunction, the displaying format is [XX:YY], in which XX stands for the current malfunction, if normal, it will display "--"; YY stands for the latest time malfunction. The failure code of every unit will display for 3 seconds. After the failure codes of all indoor units in the whole group are displayed, the mode will quit automatically.
How to change the function switches?
Master wire controller
Slave wire controller
Function All of functions
Only with below functions: ON/OFF, MODE, FAN SPEED, SET TEMP., SWING
Contrastive items
No. Type State of switch Function description
Select the master or the slave controller
ON set as the slave controller
OFF
SW1-1
OFF set as the master controller
Select the controller mode
ON
standard controller
SW1-2
air handler controller
Room temperature display option
ON
visible room temperature
SW1-3
invisible room temperature
26
o
lock
ON
Unavailable 26o lock
SW1-4
available 26
o
lock Temperature sensor position option
ON
Sensor of the controller
SW1-5
Sensor in the unit
OFF
Auto restart
ON unavailable
SW1-6
available
OFF
OFF
OFF
3.Wiring instruction
Use shielded wire between indoor and wire controller.And be earthed on one side, or the unit will not work normally because of interference.
Note:Confirm the terminal connection firmly, and do not get in tough with shielded wire.
4.Place wire controller on the holder, and pay attention not to pressing any wires.
10.45
Screw holes
5.3
Bracket
Wire controller
1. Take down wire controller from the holder
2. Install the controller holder
According to the position of 2 screw holes on the holder, drill 2 holes on the wall, and strike the wood stopper to the holes respectively. Then align the 2 screw holes of wired controller holder to the wood stopper, fix the holder on the wall with wood screw. Note:Try a wall as flat as possible for installation. Don't use excessive force to tighten screws, otherwise, the holder will be damaged.
AUTO
FAN ONLY
COOL
DRY
HEAT
TES
FAN
AUTO HIGH
LOW
FIX
CENTRAL
OPERATION
STANDBY
PRE-HEAT
DEFROST
FILTER
MODE
HEALTH
SWING
CHECK
UNIT NO.
C F
DEMAND
CEN. ADD.
SYS. ADD.
MANUAL
ROOM TEMP.
SET TEMP.
TIMER
VENTILATION
CLOCKUP DOWN
ON
OFF
DAILY
AUTO
RECOVERY
NORMAL
MODE FAN SWING
HEALTH
CLOCK
TIMER
CHECK FILTER
RESET
ON/OFF
SET RECOVERY
TEMP
TIME
MED
Installation Manual For Wire Controller
14
5. Wiring connections of wire controller:
Indoor 1
Wire controller
A B C
Wire controller
Polar wire
Indoor 1
Wire controller
A B C
Wire controller
Polar wire
A B C
Wire controller
Polar wire
BC
A B C A B C
ABCABCAB
ABC
CABCABC
Indoor 1 Indoor 2 Indoor N Indoor 15 Indoor 16
Wire controller
Control wiring of wire controller
TYPE 2, FOR AD24MS1ERA, AD24MS1ERA(D),AD28/36/48NS1ERA(S)
ABCABC
AB
ABC
C
ABC
ABC
A
Indoor 1
Wire controller port
Indoor 2 Indoor N Indoor 15 Indoor 16
Wire controller
Control wiring of wire controller
Wire controller port
Wire controller port
Wire controller port
Wire controller port
(master unit)
Wire controller port
Wire controller port
Wire controller port
Wire controller port
Wire controller port
(master unit)
TYPE 1, FOR AD12/18MS1ERA,AD12/18MS1ERA(D),AD24MS2ERA,AD24MS2ERA(D),AD28MS2ERA(S),AD28MS2ERA(S)(D)
There are three methods to connection wire controller and the indoor units: A.One wired controller can control max. up to 16 sets of indoor units, and 3 pieces of polar wire must connect the wire controller and the master unit (the indoor unit connected with wire controller directly), the others connect with the master unit through 2 pieces of polar wire( 3 pieces for model AD12/18MS1ERA, AD12/18MS1ERA(D), AD24MS2ERA, AD24MS2ERA(D) and the bridge CN22 CN23 on slave units PCB should be cut off ). B. One wire controller controls one indoor unit, and the indoor unit connects with the wire controller through 3 pieces of polar wire. C. Two wired controllers control one indoor unit. The wire controller connected with indoor unit is called master one, the other is called slave one. Master wire controller and indoor unit; master and slave wire controllers are all connected through 3 pieces of polar wire.
6. Communication wiring:
The wire controller is equipped with special communication wiring in the accessories. 3-core terminal (1-white 2-yellow 3­red) is connected with the terminal A, B, C of wire controller respectively. The communication wiring is 5 meter long; if the actual length is more than it, please distribute wiring according to below table:
Communication wiring length(m) Dimensions of wiring < 100 0.3mm2x3-core shielded wire 100 and <200 0.5mm2x3-core shielded wire 200 and <300 0.75mm2x3-core shielded wire 300 and <400 1.25mm2x3-core shielded wire 400 and <600 2mm2x3-core shielded wire
*One side of the shielded sheet of communication wire must be earthed.
, AD28MS2ERA(S), AD28MS2ERA(S)(D)
"HOT KEEP" function
Heating Mode
15
"HOT KEEP" is operated in the following cases.
When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode. Defrosting operation (in the heating mode): When it is liable to frost, the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation. When the room thermostat is actuated: When room temperature increases and room temperature controller actuates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.
Heat pump type warming With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized. Defrosting operation When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat exchanger of outdoor unit along with the drop of indoor temperature. Since the accumulated frost reduces the effect of warming, it is necessery to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted. Atmospheric temperature and warming capacity Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature. When the warming capacity is not sufficient, it is recommended to use another heating implement. Period of warm-up Since the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room temperature rises. It is recommendable to start the operation a little earlier in a very cold morning.
Warming operation
Points to observe
Turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatile liquid.
ON
OFF
Thinner
Do not use!
Benzine Tooth powder
Cleaning the air filter
Do not dry the air filter with fire. Do not run the air conditioner without the air filter.
Pre-Season Care
See that there are no obstacles blocking the air inlet and air outlet of both indoor and outdoor units. Make sure that the air filter is not dirty. Cut in the power supply switch 12 hours before starting run.
Post-Season Care
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch. Electric power is consumed even the air conditioner is in stop. Clean the air filter and set it in the place.
Care and Cleaning of the unit
Clean with soft and dry cloth. If it is very dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet with the water. After wiping, clean off the detergent using clean water.
1.Clean the air filter by lightly tapping it or with the cleaner. It is more effective to clean the air filter with water. If the air filter is very dirty, dissolve neutral detergent in the lukewarm water (approx. 30 C), rinse the air filter in the water, and thoroughly wash the air filter off the detergent in the plain water.
2.After drying the air filter, set it up on the air conditioner.
Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped.
CAUTION
CAUTION
Care and Maintenance
16
Please check the following things about your air conditioner before making a service call.
When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the air conditioner and contact your sales dealer.
The fuse or breaker often shuts down. Water drops off during cooling operation. There is a irregularity in operation or abnormal sound is audible. When the CHECK LED (red) flickers, an irregularity has occurred in the air conditioner.
Unit fails to start
ON
OFF
Is the power source switch adjust cut in?
Is city supply power in normal?
Isn't the signal receiving section exposed to the direct sunlight or strong illumination?
Isn't the earth leakage breaker in action?
It is dangerous. Turn off the power supply switch immediately and contact the sales dealer.
Power supply switch is not ON.
Cooling or heating is not sufficient
Is the thermostat adjust as required?
Isn't the air filter dirty? Isn't any doors or windows
left open?
Doesn't any obstacle exist at the air inlet or outlet?
Cooling is not sufficient
Isn't sun-shine invading direct? Isn't any unexpected heating
load generated?
Isn't the room much crowded?
Isn't the swing louver horizontal? (At HEATING mode) If swing louver is horizontal, the blow wind does not reach floor.
The wind does not blow during heating operation
Isn't it warming up?
Power stoppage?
Troubleshooting
17
The followings are not malfunction
Shuru
Shuru
When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble.
Water flowing sound is heard.
This is caused by heat expansion or contraction of plastics.Cracking sound is heard.
It smells. Air which blows out from the indoor unit sometimes smells. The smell results
from residents of tobacco smoke or cosmetics stuck inside of unit.
When the air conditioner is used at restaurant etc. where dense edible oil fume is always exists, white fog sometimes blows out of air outlet during operation. In this case consult sales dealer for cleaning the heat exchanger.
During operation, white fog comes out of indoor unit.
Unit does not start
Wait for three minutes
It is switched into the FAN mode during cooling.
To prevent frost from being accumulated on the indoor unit heat exchanger, it is sometimes automatically switched to the FAN mode,but it will soon return to the cooling mode.
Even if the operation switch is turned on, cooling, dehumidifying or heating is not operable for three minutes after the conditioner is stopped. Because the protecting circuit is activated. (During this time air conditioner operates in fan mode.)
The air conditioner can not be restarted soon after it stops.
Air does not blow or the fan speed can not be changed during dehumidifying.
During operation, operation mode has changed over automatically.
Water or steam generates from the outdoor unit during heating.
When it is excessively cooled during dehumidifying, the blower automatically repeats reducing and lowering the fan speed.
Isn't the AUTO mode selected? In the case of AUTO mode, operation mode is changed automatically from cooling to heating or vise-versa according to the room temperature.
This results when frost accumulated on the outdoor unit is removed (during defrosting operation).
Troubleshooting
18
19
Troubleshooting
When failure happens,the fan of indoor unit stop running.The method of check failure code see page 12. For outdoor failure,the failure code is outdoor failure LED flash times + 20. For example,the failure code of outdoor unit is 2. the wired controller of indoor unit will display 16(using hexadecimal method).
Ta: ambient temperature sensor Tm: coil temperature sensor
WARNING
Please read these "Safety Precautions" first and then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the section. However, there is also a possibility of serious consequences in relationship to the points listed in the section as well. In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned. After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual. Moreover, ask the customer to keep this sheet together with the owner's manual.
This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction. Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires. Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires. When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident. For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit. Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used. Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires. Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire. Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire. When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R410A) within the refrigeration cycle. Rupture and injury caused by abnormal high pressure can result from such mixing. Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.
WARNING
CAUTION
Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock. The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock. Do not install the unit where there is a concern about leakage of combustible gas. The rare event of leaked gas collecting around the unit could result in an outbreak of fire. For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.
CAUTION
WARNING
CAUTION
Precaution for Installation
20
For inspection and maintenance
When you change your address or the installation place
Electric work
Confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself.
Installation place
Avoid installing the air conditioner near the place where possibility of inflammable gas leakage exists.
Install the unit at well ventilated place.
Install the air conditioner firmly on the foundation that can fully support the weight of the unit.
If not, it may cause vibration or noise.If some obstacle exist, it may cause
capacity reduction or noise increase.
Explosion (Ignition) may occur.
Select the place so as not to annoy neighbor with the hot air or noise.
Snow protection work is necessary where outdoor unit is blocked up by snow.
It is advisable not to install the air con­ditioner at the following special place. It may cause malfunction, consult the sales dealer when you have to install the unit on such a place.
The place where corrosive gas generates (Hot spring area etc.) The place where salt breeze blows (Seaside etc.) The place where dense soot smoke exists The place where humidity is extraordinarily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is considerably large
For details consult your sales dealer.
The electric work must be burden on the authorized engineer with qualification for electric work and grounding work, and the work must be conducted in accordance with electric equipment technical standard.
The power source for the unit is to be of exclusive use. An earth leakage breaker should be installed.(This is necessary to prevent electric shock.) The unit must be grounded.
Special technology is required for removal or reinstallation of air conditioner, consult the sales dealer. Besides, construction expense is charged for removal or reinstallation.
The capacity of air conditioner will decrease by contamination of inside of unit when it is used for about three years although depending upon the circumstances under which it is used, and so in addition to the usual maintenance service, special inspection/maintenance service is necessary. It is recommended to make a maintenance contract (charged) by consulting your sales dealer.
Is The Unit Installed Correctly
21
22
Avoid installation and use at those places listed below.
Places exposed to oil splashes or steam (e.g. kitchens and machine plants). Installation and use at such places incur deteriorations in the performance or corrosion with the heat exchanger or damage in molded synthetic resin parts. Places where corrosive gas (such as sulfurous acid gas) or inflammable gas (thinner, gasoline etc.) in generated or remains. Installation and use at such places cause corrosion in the heat exchanger and damage in molded synthetic resin parts. Places adjacent to equipment generating electromagnetic waves or high-frequency waves such as in hospitals. Generated noise may cause malfunctioning of the controller.
NOTE All wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions
do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor.
WARNING
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE.
Preparation of indoor unit
Before or during the installation of the unit, assemble necessary optional panel etc. depending on the specific type.
Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user.
Places where chilled or heated air circulates freely. When the installation height exceeds 3m warmed air stays close to the ceiling. In such cases, suggest your client users to install air circulators. Places where perfect drainage can be prepared and sufficient drainage. Places free from air disturbances to the suction port and blowout hole of the indoor unit, places where the fire alarm may not malfunction or short-circuit. Places with the environmental dew-point temperature is lower than 28 and the relative humidity is less than 80 %. (When installing at a place under a high humidity environment, pay sufficient attention to the prevention of dewing such as thermal insulation of the unit. ) Ceiling height shall have the following height.
50mm
Obstacle
Installation space
C
Combination with silent panel
416mm
366mm
a. b.
c. d.
e.
a.
b.
c.
Indoor Unit
100mm 100mm
Pipe size
AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD12MS1ERA AD12MS1ERA(D) AD18MS1ERA AD18MS1ERA(D) AD24MS1ERA AD24MS1ERA(D) AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D)
AD12MS1ERA AD12MS1ERA(D)
AD24MS1ERA AD24MS1ERA(D) AD24MS2ERA AD24MS2ERA(D) AD28NS1ERA(S) AD28MS2ERA(S) AD28MS2ERA(S)(D)AD36NS1ERA(S)
Installation Procedure
Model Liquid side Gas side
9.52mm 15.88mm
9.52mm 19.05mm
6.35mm 9.52mm
6.35mm 12.7mm
AD18MS1ERA AD18MS1ERA(D)
AD48NS1ERA(S)
2.Installation of indoor unit
Fix the indoor unit to the hanger bolts. If required, it is possible to suspend the unit to the beam, etc. Directly by use of the bolts without using the hanger bolts.
When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot holes of hanging bracket.
Note
Adjusting to the levelness
(a) Adjust the out-of levelness using a level or by the following method.
Make adjustment so that the relation between the lower surface of the unit proper and water level in the hose becomes as given below.
(b) Unless the adjustment to the levelness is made properly, malfunctioning or failure of the float switch may occur.
Tap selection on blower unit
(When the high performance filter is used.)
Taps of blower unit are set at the standard selection at the shipping from factory. Where the static pressure is raised by employing such option as the high performance filter, etc., change the connection of connectors provided at the flank of control box as shown below.
PVC hose
Piping side
Supply water
Water level
0~5 mm
(0~0.2")
Bring the piping side slightly lower.
Hanging bolt
M10 nut
Main unit
M10 washer
M10 spring washer
Red
Yellow
White
Standard tap (at shipping) High speed tap
Black
White
Connector white
Connector white
Control box side
Moter side
Moter side
Red
Blue
Red
Yellow
White
Blue
Red
Yellow
White
Blue
White
Blue
Red
1. Preparation for suspending the unit
a.Size of hole at ceiling and position of hanging bolts
<Combination with silent panel>
b.Hanger bolts installation
Use care of the piping direction when the unit is installed.
Hanging bolt M10
Hole-in anchor Hole-in plug
Insert
Concrete
Indoor Unit
150
A
B
C
Hanging bolt position
Ceiling hole size
Panel dimensions
300
30
30
Ceiling ~ panel wrap dimensions
Ceiling ~ panel
wrap dimensions
Hanging bolt position
Ceiling hole size
Panel dimensions
75
D
E
F
70
Pipe connection
side
150
A
B
C
Hanging bolt position
Ceiling hole size
Panel dimensions
300
30
30
Ceiling ~ panel wrap dimensions
Ceiling ~ panel
wrap dimensions
Hanging bolt position
Ceiling hole size
Panel dimensions
75
D
E
F
70
Pipe connection
side
Installation Procedure
23
AD12MS1ERA AD12MS1ERA(D) AD24MS1ERA AD24MS1ERA(D) AD18MS1ERA AD18MS1ERA(D) AD28NS1ERA(S) AD36NS1ERA(S) AD24MS2ERA AD24MS2ERA(D) AD48NS1ERA(S) AD28MS2ERA(S) AD28MS2ERA(S)(D)
Dimensions
A(mm)
B(mm)C(mm)
Model
D(mm)E(mm) F(mm)
987 1172
1437 1622
1497 1682
545 480
690 625
750 685
705 983
1155 1433
1215 1493
595 595
740 740
800 800
AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD24MS1ERA AD24MS1ERA(D)
AD12MS1ERA AD12MS1ERA(D) AD18MS1ERA AD18MS1ERA(D)
AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D)
Drain Piping
Drain piping should always be in a downhill grade (1/50~1/100) and avoid riding across an elevation or making traps.
When connecting the drain pipe to unit, pay suffcient attention not to apply excess force to the piping on the unit side. Also, fix the piping at a point as close as possible to the unit.
For unit with water pump drain pipeuse hard PVC general purpose pipe VP which can be purchased locally. When connecting, insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp. Adhesive must not be used for connection of the drain socket and drain hose (accessory).
Drain hose
Stage difference part
Drain socket
Drain socket
Main unit
VP(field purchased)
Pipe cover(large) [for insulation] (accessory)
VP(field purchased)
Pipe cover [for insulation] (field purchased)
Drain hose (accessory)
Pipe cover(small) [for insulation] (accessory)
Clamp (accessory)
Adhesion
Do not pipe under water
Keep free from traps
Avoid riding across an elevation
Air vent
Improper pipingGood piping
1.5m ~ 2m
Suspension bolts
Heat insulation
A downhill grade of 1/100 or more
(b)
(c)
VP-30
Secure the elevation as high as possible (approx. 100 mm)
A downhill grade of 1/100 or more
Right overhead
Drain hose
Joint for VP (Local procurement)
600
(Maximum local drain up dimension)
290~325mm
Avoid positioning the drain piping outlet at a place where generation of odor may be stimulated. Do not lead the drain piping direct into a sewer from where sulfur gas may generate.
(d)
(e)
(f)
(h)
(a)
When constructing drain piping for several units, position the common pipe about 100 mm below the drain outlet of each unit as shown in the sketch. Use VP-30(11/4") or thicker pipe for this purpose.
The hard PVC pipe put indoor side should be heat insulated. Do not ever provide an air vent.
The height of the drain head can be elevated up to a point 500 mm above the ceiling, and when an obstacle exists in the ceiling space, elevate the piping to avoid the obstacle using an elbow or corresponding gadget. When doing this, if the stretch for the needed height is higher than 500 mm, the back-flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan. Therefore, make the height of the drain pipe within the distance given in the sketch below.
Drain Pipe
For unit without water pump
For unit without water pump,please refer to the digram and select drain pipe size according to drain opening inner diameter size. The drain pipe shall be slant downwards (greater than 1/100). The horizontal length of the drain pipe shall be less than 20 m. In case of long pipe, supports shall be provided every 1.5~2m to prevent wavy form. Central piping shall be laid out according to the right figure. Take care not to apply external force onto the drain pipe connection part.
(g)
For unit with water pump
Installation Procedure
24
1.5m~2m Support
Insulation (supplied by the user)
Down slope above 1/100
AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD24MS1ERA AD24MS1ERA(D) 15.5mm
AD12MS1ERA AD12MS1ERA(D) AD18MS1ERA AD18MS1ERA(D) 21mm AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D)
33mm
Unit model The size of d rain opening
Installation work for air outlet ducts
Calculate the draft and external static pressure and select the length, shape and blowout.
A Blowout duct
2-spot, 3-spot and 4-spot with 200 type duct are the standard specifications.
Note (1) Shield the central blowout hole for 2-spot. (2) Shield the blowout hole around the center for 3-spot.
Limit the difference in length between spots at less than 2:1. Reduce the length of duct as much as possible. Reduce the number of bends as much as possible. (Corner R should be as larger as possible.) Use a band. etc. to connect the main unit and the blowout duct flange. Conduct the duct installation work before finishing the ceiling.
Connection of suction, exhaust ducts
a.Fresh air inlet
Inlet can be selected from the side or rear faces depending on the working conditions. Use the rear fresh air inlet when the simultaneous intake and exhaust is conducted. (Side inlet cannot be used.)
b.Exhaust (Make sure to use also the suction.)
Use the side exhaust port.
Good exampleBad exampleBad example
Exhaust hole
State seeing from top of unit
Side fresh air inlet
Rear fresh air inlet
Fig.1
Fig.2
Drainage Test
Conduct a drainage test after completion of the electrical work. During the trial, make sure that drain flows properly through the piping and that no water leaks from connections. In case of a new building, conduct the test before it is furnished with the ceiling. Be sure to conduct this test even when the unit is installed in the heating season.
Attached drain hose clamp
Drain piping
Main unit
Drain situation can be checked with transparent socket
Remove grommet. Make sure to install it back after test.
Insert water supply hose for 20 mm ~ 30 mm to supply water. (Insert hose facing toward bottom.)
Pour water into a convex joint.
Procedures
Supply about 1000 cc of water to the unit through the air outlet using a feed water pump. Check the drain while cooling operation.
Before the electrical work has not been completed, connect a convex joint in the drain pipe connection to provide a water inlet. Then, check if water leaks from the piping system and that drain flows through the drain pipe normally.
(1) (2)
(3)
(4)
(a)
(b)
Ceiling surface
Heat insulation
Suction panel (Silent panel)
Air conditioner main unit
Special blowout (Option)
Blowout duct (Optional or marketed item)
Hole for check
special inlet (option) (with air filter)
inlet duct (optional or marketat item)
B
A
C
Drain Pipe
Air Duct
Installation Procedure
25
Installation Procedure
Electrical wiring
WARNING
DANGER OF BODILY INJURY OR DEATH
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS.
Precautions for electrical wiring
Electrical wiring work should be conducted only by authorized personnel. Do not connect more than three wires to the terminal block. Always use round type crimped terminal lugs with insulated grip on the ends of the wires. Use copper conductor only.
Installation Procedure
26
Selection of size of power supply and interconnecting wires
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2% voltage drop.)
Wiring connection
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by terminals.
Item
Model
Phase
Switch
breaker
(A)
Circuit breaker
Overcurrent
protector
rated capacity
(A)
Power source
wire size
(minimum)
(mm2)
Switch
breaker(A)
Earth leakage breaker
Leak
current(mA)
301 40 30 6.0 40
AD48NS1ERA(S)(Outdoor 3 phase type)
Outdoor unit terminal block
Indoor unit terminal block
Power supply:1PH,220-230V~,50Hz
Y/G
1 2 3
Y/G
1 2 3
L N
Outdoor unit terminal block
Indoor unit terminal block
Power supply:380-400V, 3N~,50Hz
Y/G
1 2 3
Y/G
1 2 3
R S T N
301 40 26 4.0 40
AD28MS2ERA(S) AD28MS2ERA(S)(D) AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)
AD12MS1ERA AD12MS1ERA(D) AD18MS1ERA AD18MS1ERA(D) AD24MS1ERA AD24MS1ERA(D) AD24MS2ERA AD24MS2ERA(D)
AD12MS1ERA AD12MS1ERA(D) AD18MS1ERA AD18MS1ERA(D) AD24MS1ERA AD24MS1ERA(D) AD24MS2ERA AD24MS2ERA(D) AD28MS2ERA(S) AD28MS2ERA(S)(D) AD28NS1ERA(S) AD36NS1ERA(S) AD48NS1ERA(S)(Outdoor single phase type)