Haier AD212BMBAA user guide manual

Auto, Cooling, Dehumidifying, Heating operation
AD212BMBAA
Haier Network Air Conditioner
Two by One Room Air Conditioner
CONTENTS
Name of Parts Safety Precautions
Operation Instruction Fan Operation
Timer On/Off Function
Sleep Function
Timer On-Off Function
Maintenance Maintenance
Usersí Attention
Installation of Indoor Unit Installation Instruction
Installation Procedure
Operation Points
Troubleshooting
No:
0010571573
Please read this manual carefully before using Please keep this manual for future use
1 2-3 4-5
6
7
8
9
10 11
12-13 14-16
19-29
17-18
Characteristics of Products
Far distance monitoring
There is a pre-set far distance control communication interface on the control panel of indoor unit. After installing the peripheral equipment according to the manual attached with the Haier made far distance control detector, the computer management or other place monitoring can be achieved to the air conditioner.
Characteristics of Products
1.Free combination multi-split.
2.Prompt temperature adjustment.
3.Inner hidden type installation, space saving.
4.Large screen LCD display, easy and convenient operation.
5.Super quiet design.
6.Powerful circular air volume.
7.This air conditioner has POWER FAILURE RESUME FUNCTION. During the operation of the unit, if there is a sudden power failure, when the power resumes, the unit will resume the previous operation mode.
8.This unit has the function of far distance monitoring. Through the telephone network, it can be effectively controlled in any other far­ distance place.(Only after equipped with the ìfar distance detectorî made by our company can this function be fulfilled.)
1
Change of fan speed
In COOLING mode, the air sending is set at AUTO, when the indoor temperature is near the set temperature, the fan speed will lower automatically . In HEATING mode, when room temperature reaches the set temperature, the compressor will stop running, and the fan will change to LOW FAN or stop.
In DEHUMIDIFYING mode, the fan speed will change automatically.
3-minute protection function
If start the unit immediately only after it is turned off, the compressor will start after 3 minutes have elapsed to protect the compressor.
Operation of air conditioner
When the ambient humidity is too high, in COOLING or DEHUMIDIFYING mode, there may be water dropped in the air outlet.
Anti-cold air blowing out
During Heating operation, after starting the unit, the indoor fan motor will not rotate immediately to prevent cold air from blowing out.
Defrosting function
During Heating operation, when frost formed on the heat exchanger of outdoor unit, the air conditioner will defrost automatically for several minutes. During defrosting, both the fan of indoor and outdoor unit do not run. After finishing defrosting, the air conditioner will automatically resume operation.
Hint
When the air conditioner is in Heating mode, it absorbs heat from outside and release to indoors. So the outdoor temperature may affect the Heating effect.
Power failure resume function (please set and use this function according to actual condition)
After setting power failure resume function, if there is a sudden power failure during unit operation, when power on for again, the unit will resume the previous state.
Setting method: when the wire controller is in ON state (except for TIMER and FAN
mode), press the SLEEP button for 10 times in 5 seconds, after the buzzer sounds 4 times, the unit will change to POWER FAILURE RESUME function. Cancellation method: press the SLEEP button 10 times in 5 seconds, after the buzzer 2 times, the POWER FAILURE RESUME function is cancelled.
Note: After the unit is set POWER FAILURE RESUME function, if there is a sudden power failure
in using, during this period of time if there is no need to use the unit for a long time, please cut off power to prevent the air conditioner from automatically resuming to the previous setting if powerfailure resumes, or press the ON/OFF button to turn off the unit after power failure resumes.
Operation points
Please wait
?
2
Wire Controller
HEAT
AUTO
SET
ROOM
MODE FAN SWING
TEMP
CLOCK SET
TIMER SLEEP
RESET
FILTER RESET
ON/OFF
Indoor Unit
1
2
* Air outlet * Ventilation hole
Name of Parts
Name of Parts
Wire Controller
14.Network control display
Used to adjust the time of timer and clock
When the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume norma
After cleaning the air inlet, press this button, the unit can start to operate
12.Humidifying state display
Used to turn on/off unit
1.ON/OFF button
6.Air filter cleaning display
7.Super/Soft operation display
13.Sleep state display
2.Temperature display
24.Time Adjusting button
23.Sleep button
Used to set Sleep state or Power Failure Resume Function
When there is too much dust collected on the air inlet, the wire controller will show this display to remind the user to clean the air inlet. After cleaning and installation, just press the air filter reset button.
8.Fan speed display
9.Auto Swing display
11.Fresh air state display
25.Reset button
26.Air Filter Reset button
27.Timer button
Used to set the mode of timer
28.Lock state display
29.Electric heating button
4.Timer ON/OFF display
3.Clock display
17.Operation mode button
5.Humidity display
22.Setting button
Used to confirm the time of timer and clock
15.Working mode display
21.Clock button
Used to calibrate the time of timer and clock
16.Electric heating display
Used to set working mode:Auto, Cooling, Dehumidifying
,
Heating, Fan
18.Fan speed button
Used to set fan speed: Low Fan, Med Fan, High Fan, Auto
20.Temperature Setting button
10.Health state display
Used to set temperature,
temperature range
: 16*~30*
19.Swing button
Used to set Auto Swing or Fixed air sending direction
3
Calibration of clock
When turning on the unit for the first time, the clock should be calibrated. The method of calibration is:
1.Press ìClockî button, the Clock display ìAMî ìPMî will flash.
2.Press
* or * to adjust time. For each press, the time will increase or*decrease 1
minute. If depressing the button, the time will increase or decrease*rapidly.
3.After confirming the time, press ìSetî button, ìAMî or ìPMî will stop flashing, the clock will begin to work.
Note:
1.This model does not have the following related display and function
2.Non-electric heating type, there is no electric heating button and electric heating display
* * 10 11 12 28
16
29
Auto
Low Fan Med Fan High Fan Auto
Working mode
Auto operation
Cooling operation
Dehumidifying operation
Heating operation
Fan operation
Wire controller
29
MODE FAN SWING
TEMP
CLOCK
TIMER
SET
SLEEP
HEAT FILTER RESET
SET
ROOM
RESET
ON/OFF
1
2
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
20 21
22 23
24 25 26 27 28
AUTO
10
19
4
Safety Precautions
Before starting the unit, please read the following ìSafety Precautionsî carefully to guarantee the normal operation of the system. The following lists two kinds of safety precautions ì Warningî and ì Noticeî. For the items that the improper use may cause death or serious injury are listed in ì Warningî volume. However, sometimes the items listed in ì Noticeî volume may also cause serious accidents. So, these two volumes are the important contents related to safety, they must be observed.
Installation Safety Precautions
Warning
The system should be applied to places as office, restaurant, residence and the like.
The system should be installed by your dealer or a professional installer.
Application to inferior environment such as workshop, it may cause equipment malfunction and serious injury or death.
Installation by yourself is not encouraged. Because improper installation could cause water leakage, electric shock and fire accident.
Notice
Operation safety precautions
Do not let the cold wind blow to human body for a long time.
When any abnormal condition (scorching smell or others) is found, stop operation immediately and turn off the power switch. Then consult your dealer.
Warning
It may affect the physical condition or cause some health problems.
If continuing the operation without removing the cause, it may cause trouble, electric shock or fire.
After carefully reading this manual, please keep in hand for reference. If the air conditioner is given to a new user, this manual should be attached with unit to the new user.
Grounding wire should never be connected to gas pipe, city water pipe, lightning conductor rod or the telephone line. If the grounding wire is not set properly, it may cause electric shock.
ON
OFF
A creepage breaker must be installed at the installation place
Drain pipe should be arranged properly to provide a smooth drainage.
Unless the circuit breaker is installed, it may cause electric shock.
If the pipe is arranged improperly, furniture or the like may be damaged by the leaked water.
Make sure the system is grounded.
Notice
Do not handle switches with a wet hand.
It may cause electric shock.
Do not use water to clean the air conditioner. It may cause electric shock.
Do not do like this Do follow the instruction Do equip with grounding wire
Safety Precautions
5
Notice The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision devices or work of art.
Do not put the fire devices in the places, which the air from the air conditioner can directly blow.
It may cause deterioration of the articles.
It may cause the fire devices cannot burn completely.
Do not install the system where the air outlet may directly reach the flora and fauna.
Only use the proper specified fuse.
It will not be good for their health.
If use metal wire or copper wire to replace the fuse, it may cause trouble and fire accident.
Do not put or use any spray near the air conditioner, and do not directly spray to the air conditioner.
Otherwise it may cause fire.
Safety precautions when moving, reinstalling and repairing the air conditioner
Warning
Do not use the power switch to turn of or off the air conditioner.
Do not use such equipment as a water heater,etc., around the indoor unit or the wire controller.
It may cause fire or Creepage.
If the system is operated at the vicinity of such equipment that generates steam, condensed water may drip during cooling operation or it may cause Creepage or short-circuit.
When operating the system simultaneously with a combustion apparatus, indoor air must be ventilated frequently.
Insufficient ventilation may cause the danger of lack of oxygen.
When cleaning, please stop the unit and cut off the power first.
Do not put the water containers, such as vase, on the unit.
Do not perform cleaning, when the indoor fan motor is rotating in high speed.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
Do not refit the air conditioner. When repair is needed, please contact your dealer.
When moving the air conditioner to another installation place, please contact the dealer or
the professional installer. Improper repair may cause water leakage, electric shock and fire accident.
Improper moving and reinstallation may cause
water leakage, electric shock and fire accident.
ON
OFF
Operation instruction
3
2
MODE
FAN SWING
TEMP
CLOCK
SET
TIMER
SLEEP
RESET
FILTER RESET
ON/OFF
HEAT
Fan operation
About FAN operation:
FAN operation refers the air conditioner does not perform COOLING and HEATING operation, but FAN operation. In this mode, the air conditioner cannot perform AUOT F AN operation, and does show the temperature value on the wire controller.
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller will show the previous working state (except for Timer, Sleep, Swing mode), the operation indicator light on the wire controller will light up.
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
choose FAN operation
Adjusting FAN SPEED
Press the FAN SPEED button to change fan speed:
Turn off the unit
Press the ON/OFF button to turn off the unit. The wire controller only shows the clock and room temperature.
Choose the desired fan speed
6
1
4
1
2
COOLING
DEHUMIDIFYING
AUTO HEATING FAN
3
LOW FAN MED FAN HIGH FAN
4
2
7
Operation instruction
Auto/Cooling/Dehumidifying/Heating operation
Hints:
The wire controller can memorize the working condition of each time. When start the unit for the second time, just need to press ON/OFF button, the air conditioner will work according to the previous working mode. (except for Timer, Sleep and Swing)
Turn on the unit
Press the ON/OFF button to turn on the unit The LCD display of the wire controller will show the previous working state (except for TIMER, SWING, SLEEP mode). The operation indicator light on the wire controller will light up.
Choose of working mode
Press MODE button, each press the working mode will change as the following sequence:
then choose AUTO, COOLING, DEHUMIDIFYING, HEA
TING operation.
Set temperature
*Each press , the set temperature will increase 1 degree.
*
Each press, the set temperature will
decrease 1 degree.
Set the desired temperature.
Press the TEMP. SET button
Adjusting FAN SPEED
Press the F AN SPEED button, for each press, the fan speed will change as the following sequence:
Choose the desired fan speed.
In Heating operation, after start the unit, the air conditioner will sending warm air a moment later to prevent the cold air blowing out. In Dehumidifying, when the room temperature drops 2
*
higher than the set temperature, regardless the set fan speed, the air conditioner will intermittently operate in low fan speed.
Turn off the unit
Press the ON/OFF button to turn off the unit. The wire controller only shows the clock and room temperature.
About AUTO operation:
In AUT
O operation, the air conditioner will operate and automatically choose COOLING,
HEATING or FAN operation according to room temperature.
AUTO COOLING DEHUMIDIFYING HEATING FAN
3
4
SET
ON/OFF
MODE
FAN SWING
TEMP
LOC
SET
TIMER
SLEEP
RESET
FILTER RESETHEAT
5
1
4
3
2
3
5
1
Set temperature + 2* Set temperature
When room temperature reaches set temperature + 2*, the unit will operate in mild dehumidifying operation.
Ultra-low air flow
When room temperature is higher than set temperature, unit in COOLING operation.
AUTO
LOW FAN MED FAN HIGH FAN AUTO
Timer On/Off function
Operation instruction
SET
ON/OFF
MODE
FAN SWING
TEMP
CLOCK
SET
TIMER
LEEP
RESET
FILTER RESETHEAT
2
Before using TIMER function, calibrate the clock first (referring to page 3). When you wake up in the morning, before going back to home after work or after going to bed, you can let your air conditioner automatically turn on or turn of
f.
Set of TIMER mode
Press the TIMER button to change the TIMER mode, each press the TIMER mode will change as the following sequence:
Turn on the unit
Cancel TIMER
Press the TIMER button several times until the TIMER mode display disappears.
After turning on the unit, set the desired working mode. The LCD of the wire controller will show working mode. (except for T
imer, Sleep,
Swing)
* Each press, the set time increases 10 minutes. If depress the button, the time will increase rapidly
.
*Each press, the set time decreases 10 minutes. If depress the button, the time will decrease rapidly.
Set time Press the time adjusting button
This LCD will show the time set, the time can be adjusted within 24h. (AM stands for morning, PM stands for afternoon).
Confirm the time
After calibration of the clock, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned on (TIMER ON) or turned of
f (TIMER OFF).
Hints:
After power failure, the clock should be calibrated again. The wire controller has memory function, when you use this function for the second time, if the time set is the same as the previous one, you just need to choose the TIMER mode then press the SET button to confirm.
3
1
TIMER ON TIMER OFF TIMER ON-OFF
Blank
OFFON OFFON
AM
PM
AM
PM
Then choose the timer mode as you need (TIMER ON or TIMER OFF.)At this time the or will flash.
ON
OFF
* * * *
At this time, the* *or* *will not flash.
ON
OFF
4
At this time, the" "will not flash.
OFF
Then choose the TIMER ON-OFF mode. At this time the" "will flash.
ON
2
9
Operation instruction
Timer On-Off function
Cancel TIMER
Press the TIMER button several times until the TIMER mode display disappears. According to the sequence of TIMER ON & TIMER OFF setting, you can realize turning on unit first, then turning of
f unit.
After adjusting time, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned on.
At this time, the* *will not flash ,* egins to flash.
Set the TIMER OFF time
Press the TIME button, the adjustment method is the same as the one of setting TIMER ON time.
Confirm the time of TIMER OFF
After adjusting time, press SET button to confirm time.
The time displayed is: at x oíclock x minutes the unit will be turned off.
ON OFF
Set of TIMER mode
Press the TIMER button to change the TIMER mode, each press the TIMER mode will change as the following sequence:
Turn on the unit
After turning on the unit, set the desired working mode. The LCD of the wire controller will show working mode. (except for T
imer, Sleep,
Swing)
* Each press, the set time increases 10 minutes. If depress the button, the time will increase rapidly
.
*Each press, the set time decreases 10 minutes. If depress the button, the time will decrease rapidly.
Set time
Press the time adjusting button
This LCD will show the time set, the time can be adjusted within 24h. (AM stands for morning, PM stands for afternoon).
Confirm the time
3
1
4
SET
ON/OFF
MODE
FAN SWING
TEMP
CLOCK
SET
TIMER
SLEEP
ET
LTER
HEA
5
6
TIMER ON TIMER OFF TIMER ON-OFF
Blank
OFFON OFFON
AM
PM
AM
PM
5
6
10
Operation instruction
Sleep operation
Use of SLEEP function
After turning on the unit, setting the working mode, then press SLEEP button to make the air conditioner have the previous Sleep time (powered on for the first time or after performing Sleep is 1h). The Sleep symbol will appear. Press time */* button, you can choose between 1~8h. Each press, it may increase/decrease 1h and will display in the humidity area with ìxhî, and display ìTimer Offî in Timer Off area and the time to turn off; press Sleep button again to cancel Sleep function. The Sleep symbol disappears.
Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep. Before using this function, you should calibrate the clock first, otherwise, the SLEEP function will be out of order.
2.In HEATING operation
1 hour later in SLEEP operation, the temperature will decrease 2* from the set temperature, another 1 hour later increase another 2*, then the unit will operate continuous at this temperature for 3 hours, then it increases 1*, after operating at this temperature for another 3 hours, the unit will turn off automatically. The temperature is lower than set temperature to prevent you from feeling uncomfortable during sleep.
Operation modes
1.In COOLING, DEHUMIDIFYING operation
1 hour later in SLEEP operation, the temperature will increase 1* from the set temperature, another 1 hour later increase another 1*, then the unit will operate continuous for 6 hours, then it turns off automatically. The temperature is higher than set temperature to prevent you from getting a cold.
Note:
lAfter setting Sleep function, it is not permitted to adjust clock. lThe Sleep time is less than 8h, after reaching the set time, the unit will
automatically stop. lSet Sleep function after setting ìTimer Offî function, the air conditioner will perform Sleep function.
lAfter setting Sleep function, the Timer function cannot be set. lSet Sleep function after setting ìTimer Onî function, the Sleep function can
only be set in the set time of Timer On.
SET
ON/OFF
MODE
FAN SWING
TEMP
CLOCK
SET
TIMER SLEEP
RESET
FILTER RESETHEAT
Set temperature
SLEEP operation starts
SLEEP operation stops
turn off
1 hour
about 3 hours
3 hours
decrease 2*
increase 1*
in HEATING operation
1 hour
decrease 2*
in COOLING* DEHUMIDIFYING operation
Set temperature
SLEEP operation starts
SLEEP operation stops
turn off
1 hour
about 6 hours
increase 1*
1 hour
increase 1*
Usersí Attention
Set proper room temperature
Not too low or high and make every people
in the room feel comfortable.
Do not let the cold air blows directly to human body for a long time and do not make the room temperature drop too low.
Otherwise, it may cause uncomfortable or bad to your health.
The room should often ventilate.
After a long-time of using air conditioner, the room must be ventilated.
Do not keep the doors and windows open
Otherwise, it may lower the efficiency of the air conditioner.
Television, radio and acoustics, etc. equipment should keep over 1m from indoor unit and wire controller.
Otherwise, they may disturb the image and cause noise.
Do not put any drying devices under the indoor unit.
The heat may cause the deformation of indoor unit.
If do not use the air conditioner for a long time, it is necessary to cut off power.
If do not cut off power, the unit may consume power. In order to protect the unit, before using the air conditioner again, turning on the power at least 12 hours in advance.
The windows should be hung with curtains or blinds.
Do not let the sun shine directly shine in the room; do not let the outdoor air enter room.
The articles must keep dry cannot be put under the indoor unit.
When the humidity is over 80% or the drainage outlet is blocked, the indoor unit may drop water.
Do not put articles around the air inlet and outlet.
This kind of obstacle can lower the efficiency of the air conditioner or cause unit trouble.
The air conditioner can only be used in air conditioning. It can not be used in other purpose.
Do not use the air conditioner in some specific purpose, such as storage or protect food, animals, plants, precise instrument and artwork,otherwise, the quality of them may be declined.
Do not press tightly with the LCD part of the wire controller to avoid damage of it.
The airflow cannot directly blow to the pets and plants.
Otherwise, pets and plants may be hurt.
11
Cut off power suplay
Cooling is 26~28*
Heating is 18~23*
Maintenance
12
Notice
Only after turning off the unit and cutting off the power can the cleaning of the unit be performed.
Otherwise, it may cause electric shock or injury.
Do not use water to clean the air conditioner.
Otherwise, it may cause electric shock
The repair can only be performed by the professional workers.
Before touch the wire connection device, cut off the power first.
Use stable stand support.
Please pay high attention when cleaning the unit
Notice
Clean the air filter
Clean
Notice
Do not use the hot water over 50* to clean to avoid discoloration or deformation. Do not dry the unit on fire, the filter may be burnt.
Use cleaner or water to clean to remove dust.
(A)Use cleaner to remove dust.
( B )When the dust is too much, use soft brush and neutral detergent.
( C ) Throw the water off, then put it in the shadow for airing.
Donít in
operation
Maintenance
13
Before using season
1.Check the following items: If the air inlet and outlet of indoor and outdoor unit are blocked. If the earth wire is proper. If the wire connection is proper. If there is abnormal phenomenon, please ask the after-sale service staffs for help.
2.Cleaning the air filter or air inlet and casing
After cleaning the air filter, it must be reinstalled.
3.Turn on the power
After using season
1.In a sunny day , perform half-a-day Fan operation to make the inner
of the unit dry.
2.Cut off the power
If do not cut off power, the unit will consume power. Power cutoff can save power.
3.Cleaning the air filter or air inlet and casing
After cleaning the air filter, it must be reinstalled. For the details of cleaning, please refer to Maintenance.
Maintenance before and after the using season.
After turning on the power, words appear on the LCD screen of the wire controller.
Troubleshooting
14
The following phenomena are not troubles
Symptom Cause
Hear the sound of water flow
When the air conditioner is started; during operation the compressor starts or stops; or when the unit is stopped; sometimes it gives the sound of ìHua, Huaî or ìGudu, Guduî. This is the sound of the refrigerant circulation, not trouble
It is caused by the hot expansion and cold shrink of the plastic part.
Gives ìPi, Paî sound
Having peculiar smell
Sometimes the air sent from the indoor has peculiar smell, the smell is what the cigarette smoke naturally has or caused by the inner paint of the unit.
During operation, the indoor unit produces mist.
During COOLING operation, the mode changes from AUTO to FAN.
After stopping the unit, it can not start immediately.
To prevent the frost from forming on the indoor unit heat exchanger, sometimes the unit will automatically change to FAN mode, but sooner it will resume to COOLING mode.
Even the operation button is set on ON, within 3 minutes after the unit stops, Cooling, Dehumidifying or Heating mode can not start. It is because the self­protection of the system. (In this 3 minutes, the air conditioner is in Fan mode)
During DEHUMIDIFYING, there is no air blown out or the FAN SPEED can not be changed.
In DEHUMIDIFYING operation, when the room temperature is too low, the fan motor will automatically and repeatedly drop the fan speed
During operation, the operation mode changes to Auto.
Whether choosing Auto mode? In Auto mode, according to room temperature, the operation mode will automatically change Cooling to Heating, vice versa.
During COOLING or DEHUMIDIFYING, you may see the unit produces whiffs of light mist. It is caused by the sudden cold indoor air blown out from the unit producing condensation mist.
Hua, Hua
Wait three minutes
The air conditioner does not start?
When Troubles Occur
If after the above checking and treatment, the air conditioner still can not work normally , or find the following phenomena, please stop the operation of the unit and contact the commissioned repair center.
The fuse or breaker often opens circuit. During Cooling or Dehumidifying, there is water leakage. Abnormal operation or abnormal sound is heard.
The operation indicator light on the wire controller flashes and trouble code (E0, E1, ..., E9) appears on the screen to indicate the trouble of the air conditioner.
Before asking the commissioned repair center for help, please check the air conditioner according to the following items.
ON
OFF
Is the power switch connected?
If the city electric power supply is normal?
If the wire controller is directly shined by sunshine or affected with damp.
If the earth creepage breaker works?
Please cut off power immediately and contact with suppler .
The power switch is not at ON position.
The air conditioner can not start
Bad heating effect
Did you adjust the controller as what is specified?
If the air filter is too dirty?
Are doors or windows closed?
If the air inlet or outlet is blocked by obstacles?
Bad cooling effect
If the air out louver is in horizontal? (Heating mode)
If the air out louver is horizontal, the warm air can not blow on the floor.
The air conditioner does not blow air in Heating operation, if it is in anti­cold air state? Referring to page7.
15
E8
Trouble code on wire control type indoor unit
The compressor indicator light flashes 1 time in 0.2S/time frequency
E4
The compressor indicator light flashes 2 time in 0.2S/time frequency
The compressor indicator light flashes 3 time in 0.2S/time frequency The compressor indicator light flashes 4 time in 0.2S/time frequency
The compressor indicator light flashes 5 time in 0.2S/time frequency
The compressor indicator light flashes 8 time in 0.2S/time frequency
The compressor indicator light flashes 9 time in 0.2S/time frequency
The compressor indicator light flashes 10 time in 0.2S/time frequency
When Troubles Occur
When the following phenomena appear, please contact the commissioned repair center.
Symptom
After taking the following measure, then contact the commissioned repair center
The safety equipment, such as fuse, breaker and creepage breaker, has been open circuit for many times; or the operation switch cannot work normally .
Cut off power.
The air conditioner leaks water.
Cut off power and inform the commissioned repair center.
16
Warning
If finding any abnormal phenomena (such as adust smell), cut off power first, then ask the after-sales service workers for help. If still using the air conditioner in this condition, the air conditioner may be damaged and causes electric shock or fire accident.
Trouble display
E3
E5
Phenomenon of outdoor unit trouble
The trouble of outdoor ambient temperature sensor The trouble of outdoor coil
temperature sensor Over electric current protection
CT wire breaks
The flashing time of indicator light on outdoor control panel
Indoor control panel indication
1 (A, B systems indicate together)
The communication trouble between indoor and outdoor unit
8 (A and B system indicate individually)
The trouble of outdoor coil temperature sensor
The trouble of electric current overload
2 (A and B system indicate individually)
5 (A and B system indicate individually) 6 (A and B system indicate individually)
E3
E4
E5
E8
The communication trouble between panel and indoor panel
E2
The trouble of outdoor
ambient temperature sensor
Phenomenon of indoor
unit trouble
Trouble indication on remote control type indoor unit
E5
E1
The trouble of indoor
ambient temperature sensor The trouble of indoor
coil temperature sensor
E9
The communication trouble between indoor panel and outdoor panel
E0
The trouble of water pump
17
Installation instruction
Before installing, do read this ìSafety precautionsî carefully to guarantee the proper installation. The below attentive matters are divided into ì Warningî and ì Noteî two parts. When the wrong installation occur, it is very possible death and severe injury and other serious accidents will happen. For those items are listed in ì Warningî part. But even the items listed in ì Noteî part can also cause serious accidents. Above all, both the two parts are very important contents related to safety, so they must be obeyed. After finishing the installation work, do test run to verify everything is normal. After that please explain the using and maintenance methods to the user. Additionally, give this installation manual and operation manual to the user and ask them to keep it properly.
The commissioned repair center shall do the installation work. If you do the installation work by yourself, the improper installation will cause water leakage, electric shock fire and other accidents. The installation work shall be in line with what the installation manual specified. If installation is not proper, water leakage, electric shock, fire and other accidents will occur. Install the air conditioner to a place where can definitely stand its weight. The air conditioner can not be installed on a nonmetal bracket (such as theft guard net). Places not firm enough will cause drop down of unit resulting in body hurt. The installation work shall be preventive to typhoon and earthquake. If the installation work is not met with the requirements, overturn of the unit will occur resulting in accidents. Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting part of the terminals to prevent it from the external force. Improper connection and fixing will cause heating and fire etc. accidents. Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and the external panel shall not nip the wire. Improper installation will cause heating and fire etc. accidents. When setting or moving the air conditioner do not let the air and things alike get into the refrigeration system except the specified refrigerant (R407C). If air and other things enter, abnormal high pressure will occur, which easily cause break and body injuries etc. accidents. When installing, do use the accessories or specified parts. If not using the parts specified by our company, water leakage, electric shock, fire and refrigerant leakage will occur. Do not lead the drain hose to drain where the sulfur gas may be involved. Otherwise, the poisonous gas will enter into the indoor. During installation, if refrigerant leakage occurs, do the ventilation work immediately. As soon as the refrigerant gas meets fire, poisonous gas will be produce. After installation, confirm there is no leakage of refrigerant. If the refrigerant gas enters into room and meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced. Do not install the unit in a place where the combustible gas may be leaked. In any case the combustiblegas leaks and accumulated around the unit, fire accident will occur. The drain hose should be correctly installed according to the installation manual to ensure smooth drainage, and take proper heat preservation measure to prevent from dew. Improper pipe installation may cause water leakage result in wet the indoor articles. Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat preservation. If the heat insulation measure is not sufficient, water generated by condensing dew will drip leading to wet the floor and indoor articles.
Do grounding work. Do not connect the grounding wire to gas pipe, tap, lighting rod or telephone line. Improper grounding will cause electric shock. In some places the creepage breaker shall be installed. If do not install the breaker, electric shock may occur. After electric installation, power on them to do electric leakage test.
Warning
Note
3
1
4
2
5
Big wire clamp
2
6
Thermal insulation pipe
Plastic clamp
8
Seal cushion
4
7
8
Gasket
11
10
9
18
Installation instruction
Notice
Warning
This manual can not include all kinds of conditions, if you have new requirements and questions, please contact with local Haier Sales Center
.
Before installing the unit, please read this manual carefully . Improper installation may cause accidents and make unit damage or death.
Installation tools
Accessories attached with the unit
The following is the manual mentioned standard accessories, please check them by yourself. As the following figure shown
1. Screwdriver 2. Steel saw 3. 60, 70mm diameter drill
4. Spanner (diameter 17,27mm) 5. Spanner (14, 17, 19, 27mm)
6. Pipe cutter 7. Pipe flarer 8. Knife
9. Pincers 10. Leakage detector/soap water 1
1. Tape measure 12. Scraper 13. Refrigerant oil
No.
Shape & name
Amount
1
No.
Shape & name
Amount
6
Little wire clamp
Cement steel nail
Wire controller (signal wire)
* ** *
**
** *
*
* *
*
* **
A O
Screw
3
Signal wire
1
Refrigerant oil
***
6
1
2
1
Installation procedure
Install indoor unit
Obstacle
19
1. Before installation [Before finishing installation, do not throw the attached
parts installation needs]
Confirm the way to move the unit to the installation place.
Before moving the unit to the installation place, do not remove their packages.
When have to remove the package, use a soft material or protection board with
rope to lift the unit assembly to avoid unit damage or bumping a scrape.
2. Choose installation place
(1)The chosen installation place should meet the following requirements and get the userís consent. Place ensures ideal airflow distribution. The passage of airflow has no obstacles. The condensate water can be drained smoothly. Place can stand the weight of indoor unit. Place ensures enough space for maintenance. The pipe length between indoor and outdoor unit is in the permitted limit (referring to outdoor unit installation part). The indoor unit, outdoor unit, electric wire and connection wire is at least 1m away from television and radio. This is to avoid the image disturbance and noise caused by the above-mentioned home appliance. (Even if 1m away, if the electromagnetic wave is too strong, it can also cause noise.) (2)The height of ceiling The indoor unit can install on the ceiling, which height is no more than 2.7m. (3)Install and use the hoisting screw. Check if the installation place can bear the weight of unit assembly. If not certain, strengthen it before install the unit.
Space installation needed (unit: mm)
*100
*1000
*100
*60
Installation procedure
Install indoor unit
(2) If necessary, cut a opening on the ceiling for installation and checking. (in original ceiling circumstance)
For the dimension of the ceiling opening, please refer to the above Figure. Before installation, finish the preparation work of all the pipes (refrigerant pipe, drain hose) and wires (connection wire of wire controller and of indoor and outdoor unit) first to make it easy to connect them to indoor unit as soon as installation begins. Cut a opening in the ceiling, it is necessary to strengthen the ceiling to keep the ceiling level and prevent the vibration of the ceiling. For details, please consult to the builder.
(3) Install the hoisting screw (Use M10 screw bolt)
In order to bear the weight of the unit, for existed ceiling, using found­ation screw bolt, for new ceiling, using burying embedded screw bolt, burying screw bolt or spot supplied other parts.
Before going on installation, adjust the gaps with ceiling.
Hole-in anchor
Hole-in plug
3.Preparation before installation
(1) The position relation among ceiling opening and hoisting screws (unit: mm)
20
Insert
Concrete
Hanging bolt M10
690
*Dimension of ceiling opening*
545
(Hanging bolt position)
986
* Hanging bolt position*
137
*Ceiling hole size*
(Ceiling ~panel wrap dimensions)
1240
*Panel dimensions*
30
57
(Pipe connection side)
750
*Panel dimension*
7075
1180
(Ceiling ~panel
wrap dimensions)
Installation procedure
Install indoor unit
4. Installation of indoor unit
Fix the indoor unit on the hoisting screw. If necessary, suspend the unit on the crossbeam. Do not use hoisting screw, directly use screw bolt.
Note: If the dimension of main parts does not meet the opening of the ceiling, adjust the slot of suspending bracket.
Adjust to level
(a) Use gradienter or other methods to perform level adjustment. Perform level adjustment to make the relationship between the bottom surface of the equipment and the horizontal surface as the shown below.
(b) Unless adjust to horizontal, otherwise the floating switch may have trouble or misplay.
Choose the air sending of the fan motor
(When use high performance air filter)
The fan motor is equipped with red and white terminals, when in factory, the air sending has already been set at the standard choose. When using the high performance air filter, etc. optional parts leading to the static pressure rise, please according to the following figure shown to change the connection of the connector installed on the side of control box.
Red
White
Yellow
One side of the
control box
Standard air sending (when deliver the air conditioner)
High fan speed air sending
Blue
One side of
Fan motor
Connector,
Black
21
Bring the piping side slightly lower
One side of the
control box
Connector,
One side of
Fan motor
Blue
Blue
Blue
White
White
White
Yellow
Yellow
Red
Red
Red
Red
White
White
White
M10 screw nut
M10 washer
M10 spring washer
Hoisting screw
Main unit
PVC pipe
0~5 mm
(0~0.2")
Piping side
Charging water
Horizontal
Installation procedure
Install indoor unit
5.Drain hose
(a)The drain hose should always have a slant degree (1/50~1/100) to avoid the protruding part or causing water flow bend.*
(b) When connecting the drain hose with equipment, be sure not to use too much force to the pipe on one side of the equipment.At the same time, the fixation of pipe should be close to equipment as possible as it can. (c) For the drain hose, it can be the local bought stiff PVC pipe for normal purpose. When connecting, insert the end of PVC pipe into the drain hole, then use drain hose and wire fastener to fix them tight. The bond can not be used to connect drain hole and drain hose.
Drain socket
Main unit
Drain hose
VP 25 joint (field purchased)
VP 25(field purchased)
Adhesion
Clamp(accessory)
Pipe cover (large)[for insulation](accessory)
22
Drain socket
Drain hose (accessory)
Pipe cover [for insulation] (field purchased)
Stage difference part
Pipe cover (small)[for insulation](accessory)
Good pipe system Improper pipe system
1.5m*2m
Suspending screw bolt
Insulation
1/100 or more slant degree
Air outlet
Avoid protruding part
Do not have bend
Do not put pipe under water
Installation procedure
Install indoor unit
(d) When the equipped drain hose used to many units, the position of public pipe should be 100mm lower than the drain hole of any unit. As the figure shown. For this purpose, the thicker pipe should be used.
(e) The stiff PVC pipe put indoor side should be heat insulated.
(f )The lifting height of the drain hose should be at the position over ceiling within 500mm. When there is obstacle on the ceiling , use bracket and things alike to lift the drain hose to avoid the obstacle. During this work, if the extending height is higher than 500mm, the return flow of drainage may become too much leading to the drainage groove overflow. So, the height of the drain hose should be kept within the tolerance range given in the follow figure.
(g) A void putting the outlet of drain hose in the places with irritant gas generated. Do not insert the drain hose directly into drainage, where the gas with sulfur may be generated.
Test of drainage system
(a) After finishing electric engineering, perform drainage system test. (b) During test, confirm if the water properly passes through the pipe and there is no water leakage in the joint. (c) In a new house, perform test before installing the ceiling. (d) Even if installing the air conditioner in a heating operation needed season, the test also must be performed.*
Procedure
(a) Dismantle the side panel, slowly charge 1000cc water into the drain pan to confirm the smooth drainage and without water leakage. (b) In Cooling operation, check the drainage system.
23
Right overhead
Joint for VP 25 (Local procurement)
600mm
290~325mm
Drain hose
(Maximum local
drain up dimension)
Secure the elevation as high as possible (approx. 100mm)
A downhill grade of 1/100 or more
VP 30
(a)Absorb of fresh air (single air supplying)
Use side air absorbing nozzle or absorb from the air in pipe
(b)Air discharging
Use side air discharging nozzle (do use together with air absorbing)
(c) Perform thermal insulation to the duct to prevent from frosting
Please consult the after-sales service worker of Haier Air Conditioner for the choosing and installation of suction inlet, suction duct, discharging outlet and discharging duct. Calculating the design drawing and outer static pressure, and choose the discharging duct with proper length and shape.
The length difference among every duct is limited below 2:1. Reduce the length of duct as possible as can. Reduce the amount of bend as possible as can. Use heat insulation material to bind and seal the part connecting main unit and the flare part of air discharging duct. Perform duct installation work, before the fitment of ceiling.
Installation procedure
Install indoor unit
Before finishing the wiring work, install a protruding connector on the drain hose to provide a water in hole. Then, if there is water leaks from the pipe system, perform check. Finally, the water flow through the drain hose should normally pass.
6. Installation of air suction and discharging duct
7. Connection of air suction and discharging duct
Remove gromment. Make sure to install it back after test.
Insert water supply hose for 20mm~30mm to supply water. (insert hose facing toward bottom.)
Main unit
Attached drain hose clamp
Drain piping
Drain situation can be check with transparent socket
Pour water into a convex joint.
24
Connection pipe side
Absorb from the air in pipe
Side air absorbing
Connection pipe side
Absorb from the air in pipe
Do not use this nozzle for air in
Air discharging nozzle
Good example
Bad example
Bad example
Suction panel (Silent panel)
Special blowout (Option)
Blowout duct(Optional or marketed item)
Air conditioner main unit
Ceiling surface
Heat insulator
Checking hole
Inlet duct (optional or marketat item)
Special inlet(option) (with air filter)
Installation procedure
Install indoor unit
Recommend to use anti-frost and sound-absorbing duct. (locally bought) The duct installation work should be finished before the fitment of ceiling. The duct must be heat insulated. The specific air-discharging outlet should be installed at the place where the airflow can be reasonably distributed. The surface should leave a checking hole for checking and maintenance.
8.The attentive matters in installation of air suction and discharging duct
9.The examples of improper installation
Do not use air in duct and take the ceiling inner side instead. The res­ ult is because of the irregular outer air mass, strong wind and sunshine, the humidity is increased. There may be water drop on the outside of duct. For cement and other new constructions, even if not taking ceiling inner side as duct, the humidity will also be so high. At this time, use glass fiber to perform heat preservation to the whole. (use iron net to bind the glass fiber) Maybe exceeding the unit operation limit (for example: when indoor dry bulb temperature is 35*, wet bulb temperature 24*), it may lead to overload of compressor. Affected by the capacity of air discharging fan, the strong wind in the outer duct and wind direction, when unit air sending volume exceeds the limit,the discharged water of heat exchanger will overflow, leading to water leakage.
25
Air
Use screw bolt to fix
Duct
Air
Special air discharging outlet
Air discharging fan
Improper example
26
Installation procedure
Install wire controller
1.Remove the upper cover of wire controller
2.Install wire controller
Drill 2 wall holes according to the position of the 2 screw holes on the back cover of wire controller
, then hit wood in the wall holes. Put the 2 screw holes on the back cover of wire controller properly to its corresponding wood, then use wood screws to fix the back cover on the wall.
Note:
Install the back cover of wire controller on the even wall as possible as can. When tightening the wood screw, do not use to tight force, otherwise the wire controller may be damaged.
Switch
Under this series, the switch is set as:
1.ON 2. OFF 3. OFF 4.OFF
3.Indoor unit wire connection
Connect the terminals (A, B, C, D,) on the wire controller to the terminals on the indoor PC panel (A, B, C, D,) respectively
.
Dimension of signal wire:
*The connection between indoor
unit and wire controller and indoor unit and outdoor unit should use shield wire.And the two ends of the shield wire should be grounded, otherwise, the disturbance will cause unit abnormal operation.
Note:When connecting wire, please keep a certain distance between signal wire and electric wire. (over 10mm)
4. Cover the wire controller upper cover
Pay attention not to press the connection wire.
Note: (1) The power switch and the signal wire are self-provided. (2) Do not touch PC board by hand.
Note: Confirm the connection part of terminals is firm and will not touch shield wire.
Grounded
Shield wire
Grounded
Mark
1
2 3
ON
3 grades fan speed Have rise and drop
Swing
OFF 2 grades fan speed No rise and drop
Not Swing
4
The collection temperature of main panel
The collection temperature of panel
Back cover wire controller
Arrange wire from this part
AB CD
Upper cover of wire controller
The PC board is installed on the back cover of wire controller
. When remove the upper cover,
pay attention not to damage PC board.
Screw hole
Switch
Upper cover of wire controller
Back cover of wire controller
Cord kind
Shield wire (4 core)
Size
0.33mm
2
2. Dimension of connection pipe
3. The additional charging amount of refrigerant
The additional charging of refrigerant (R407C) should be complied with the installation manual of outdoor unit. It must use measurer to quantificationally charge. The additional charging amount must be complied with the specified amount.
Requirements: Both excessive charging and less charging of refrigerant will
cause the compressor trouble. It must be complied with the specified amount.
5.Leakage detection
Use leakage detector or soap water to check if the connected part of the
connection pipe and the valve cap leak.
6.Thermal insulation treatment
The thermal insulation of connection pipe should be performed at both gas side and liquid side. In COOLING, both liquid side and gas side are in low temperature, in order to prevent dew from forming, thermal insulation should be done. The thermal insulation material at the gas side must use the material with the heat resistant temperature over 120*.
The connected part of indoor unit connection pipe should be thermal
insulated.
1. Connection of pipe
Connection method For the specific max length and the max fall of connection pipe, please refer to the manual of outdoor unit.
In order to guarantee the efficiency, the pipe should be as short as possible. Daub the refrigerant oil on the joint and the flared nut. When bending the pipes, give the roundness as large as possible, to avoid
crashing the pipes. To connect the pipe, fit the center and use hand to screw the nut, then use spanner to tighten the nut, as shown in figure. Pay attention not to let alien matters, such as sand, vapor get into the pipe. The connection of indoor unit pipe must be performed by using two spanners.
4.Vacuumizing
Use vacuum pump to perform vacuumizing through the stop valve of outdoor unit. It is strictly prohibited to use the refrigerant sealed in the outdoor unit to perform air discharging.
Installation procedure
Connection of pipe
Joint
Nut
Spanner
Spanner
27
Fasten torque
32.7~39.9 N.m
Pipe diameter
61.8~75.4 N.m
Gas pipe 15.88mm
Liquid pipe 9.52mm
If do not fit the center and screw the nut hard, the screw thread may be damaged, which will cause refrigerant leakage.
Installation procedure
Electric wiring
2.The wiring method of straight terminal
For those connection wires whose end are not orbicular terminals, their wiring method is:
Loosen the connecting screw , insert the end of the wire directly into the terminal block, and then tighten screw. Pull the wire outwards slightly to confirm it is held tightly.
3.Pressing method of connection wire:
After wiring, the connection wire must be pressed with wire holding clamp. The wire holding clamp should press on the out cover of the connection wire. As the right figure shown:
Note:
All the wires should be copper core wires. The power cable of indoor unit should be equipped according to the operation
manual of indoor unit. Before finishing vacuumizing the refrigerant pipe system, do not supply power to indoor unit.
The connection of power cable should be complied with local wiring regulation.
The wiring method of orbicular terminal
Wiring method
1.The wiring method of orbicular terminal
For the connection wire which end is orbicular terminal, its wiring method is as the right figure shown. Dismantle the screw and put it through the ring at the end of the connection wire, then connect it to the terminal block and tighten the screw.
Note: When connecting the indoor & outdoor wire, check the number of the indoor & outdoor terminals, the terminals with the same number connected together with one wire. Incorrect wiring will damage the controller of the air conditioner or make the unit work abnormally.
The connection type of power cord is Y connection. If the soft power
cord is damaged, to avoid risk, it must be replaced by the manufacturer or theirspecific repair department or similar professional worker.
Connect wire between indoor & outdoor unit
According to the wiring diagram in the manual of the outdoor unit to perform wiring work.
Note: The marks on the terminals of the end of the connection wire should be corresponding one by one.
28
(Sketch map)
Correct pressing
Terminal block
Wire holding clamp
Wrong pressing
Installation procedure
Other instruction and test run
29
Other instruction
1.Power supply
The air conditioner must use a special power circuit and special air switch. The users should provide special switch, grounding wire by themselves. The wiring should be done by a qualified electrician according to the wir­ ing rules specified by national standard An creepage breaker should be installed. The grounding wire and null wire of receptacle should be strictly separated. It is incorrect to connect the null wire with grounding wire.
The connection method of power cord is Y connection. If the power cable
is damaged,in order to avoid danger, it must be replaced by the manufacturer or its specified repair center of the same qualified worker.
2. Cut and flaring method
Use pipe cutter to cut the pipe, the burrs must be removed.
After inserting the flarer, perform flared nut.
Flarer
Incorr
Slant
Broken
Uncompleted
Burrs Too long
A
Pipe diameter
Liquid pipe
Dimension A (mm)
9.52mm (3/8î)
1.0-1.2
Connect pipe
Gas pipe
1.4-2.2
19.05mm (3/4î)
Flaring dimensions as follows:
Correct
Test run
It is necessary the installer perform the test run for one time to check if the unit works normally.
Note: The wiring diagram of this model is pasted inside of the unit.
After installing the refrigerant pipe, drain hose and electric wire properly, perform test run to ensure the system not have trouble.
Loading...