Haier YR-E06, YR-H71, AD142FCBHA, AD182FCBHA Operation Manual

No. 0010573682
C
Table of Contents
Operation
5-9
Parts and Functions
1-4
11
Use shielede wires for telecommunication between wire controller and indoor unit; indoor unit and outdoor unit. Ground the shield on one side. Otherwise misoperation because of noise may occur. Signal wire is self-provided by user.
Shielded wire
ground
OPERATION MANUAL
YR-E06&YR-H71
Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
Health Function and Installating the Reciever
Installating the
wire controller
11
Installating the
wire controller
5. Replace the upper cover of wire controller
Note
Try as far as possible a flat surface for installation. Don't use excessive force when tightening screws, or lower part might got deformed.
Hint
1. Power supply switch and signal wire should be prepaired by the user.
2. Don't touch PCB with hand.
Be careful not to hold down the wiring.
1. Remove upper cover of wire controller
Remove upper part of wire controller by press.
Lower cover of wire controller
Upper cover of wire controller
2. Install the wired remote controller
Please drill two holes on the wall according to the back cover screw hole position of the wire remote controller, then strike the wood block to the holes respectively, then align the 2 screw hole of the wire controller back cover to the wood block, fasten the wire reote controller to the wall use wood screws.
3. Switch setting
The switchs setting as follows:1.ON 2.OFF 3.ON 4.OFF
4. Connecting method as the following chart
Back cover of the wire controller
PCB is mounted on lower part of wire controller, be careful not to damage it.
Switch button
Screw hole
No
Symbol
colour
contents
1
2
3
4
A
B
C
D
White or Green
Red
Yellow
COM
Gnd
12V
Remote controlller
Wire remote controlller
Remote controlller is an accessory, to be ordered extrally
Remote controlller
Remote receiver
Installation of receive display Because of the temperature sensitive device, do not install the receive display at straight sunlight place, either in front of air outlet grill, for it is effected greatly from cool air and heat air, the receive display is at least 20mm distance to the air outlet grill. Since there is light sensitive device which receives wireless remote signal, so do not installed behind the window curtain or other obstacles, in order not to obstruct the signal. Must fix the remote control wire far from strong electricity (such as the wiring of electric light, air cond­itioner, etc.) and weak electricity (such as the wiring of telephone, interphone, etc.).
2.Place the panel onto the fixed frame, pay attention that the four claws must be placed into the corresponding four poles on the frame
1.Fix the receive display with screws on the selected place
C
C
1
3
4
5
2
OFF
RESET
LOCK
SLEEP
FAN
TEMP
ON
OFF
SWING
MODE
CLOCK
CODE
LIGHT
OFF
A U T O
RESET
LOCK
SLEEP
FAN
TEMP
ON
OFF
SWING
MODE
CLOCK
CODE
LIGHT
OFF
A U T O
CLOCK
RESET
LOCK
SLEEP
FAN
TEMP
ON OFF
SWING
MODE
CODE
LIGHT
OFF
A U T O
1
fig(1)
Left picture is a wired remote controller, which can be used on
Series
wired control units ,The remote controller can be purchased extrally. Wired remote Controller using method:
1.Use one wired remote controller. See fig (1)
2.Also can buy a remote controller extrally, realize wired remote control + remote control dual control modes.
3.When the remote controller can be used on series wired remote controller units ,than please press the botton "CODE"to choose the program of code "A"
4.Series wired remote control units have power
failure
compensation.
The right figure is a remote controller, which can be used on
series
remote control units and the matching remote control receiver
1.Remote control receiver using method : Use remote controller control the remote control window of the remote control receiver.
2.
Series
remote controller units please press the botton "CODE"to choose the program of code "B"
3.
Series
remote control units have not power
failure compensation.
fig(2)
FRESH
HIGH/SO
TIMER
SET
FILTER
B
A
M D
HEALTH
FRESH
HIGH/SO
TIMER
SET
FILTER
B
A
M D
HEALTH
Parts and Functions
HEAT
HEAT
HEAT
HEAT
SET
ROOM
MODE
FAN
TEMP
CLOCK SET
TIMER SLEEP
RESET
FILTER RESET
HEALTH
SWING
C
ON
OFF
*
AUTO
ON/OFF
SET
ROOM
MODE
FAN
TEMP
CLOCK SET
TIMER SLEEP
RESET
FILTER RESET
HEALTH
SWING
C
ON
OFF
*
AUTO
ON/OFF
10
Health Function and Installating the Reciever
Connecting wiring method of receiver :
Refer the indoor unit wiring diagram . Safety cautions see the electrical wiring part .
1.How to use the health function (only for units with this function) After set the right function mode, press health button, remote controller or wire controller displays " ",oxygen pump or negative ion generator starts up to apply oxygen or negative ion to indoor unit. Press the button again,the sign " " disapp­ eared and negative ion generator stops working. After all health function of the indoor unit being fully canceled, oxygen pump stopped.
On the "Health" mode, if you want to setting timing open mode, should close the health first: On the timing open mode, please don't use health function.
About health function
CAUTION: When the temperature of the outdoor unit is lower than 4 , oxygen pump is automatically stopped, if press health button just then, oxygen pump could not start up. But if the air condi­tioner has the negative ion function simultaneous,when press the Health button, negative ion function could still be operated. When the temperature of the outdoor unit is higher than 6 , oxygen pump could automatically resume to oxygen-make function.
1 .Emergency switch 2 .Running lamp: When the compressor working, this lamp bright. 3 .Timing lamp: When the unit been setting Timing running, this lamp bright. 4 .Power lamp: After open the unit, this lamp bright when the unite enter health running, the lamp change from orange to blue lamp. 5 .Indoor temp. sensor: Test the room temperature.
FRESH
HIGH/SO
TIMER
SET
FILTER
HEALTH
MODE
FAN
HEALTH
TEMP
CLOCK SET
TIMER SLEEP
RESET
ON/OFF
AM
SET
AM
SWING
FILTER RESET
HEAT
HEAT
Loading...
+ 4 hidden pages