Haier AB182ACAEA, AB282ACAEA, AB42NACAEA Operation And Installation Manual

Please read this operation manual before using the air conditioner.
No.0010575661
Operation & Installation Manual
AB182ACAEA AB282ACAEA AB42NACAEA
CASSETTE TYPE AIR CONDITIONER
Contents
Cautions
...........................................................................................
Introduction to Spare Parts
................................................................
Maintenance
...................................................................................
Trouble Shooting
..........................................................................
When Trouble Happens
..................................................................
Customer Need-to-know
......................................................................
Installation Procedure
....................................................................
1-5
6
7-12 13-14 15-16
17
18-28
Cautions
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
2
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Model
H07RN-F 5G 2.5mm
2
H07RN-F 3G 4.0mm
2
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.
AB282ACAEA AB42NACAEA
AB182ACAEA
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
Cautions
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided. The requirement of the power cable:
The requirement of the connecting cable: H04RN-F 4G: 2.0mm2x3+0.75mm2x1 (AB282ACAEA AB42NACAEA) H04RN-F 4G: 4.0mm2x2+2.0mm2x3 AB182ACAEA) ll the cables shall have got the European a uthentication certificate. . The breaker of the air conditioner should b e all-pole switch; and the distance between i ts two contacts should be no less 3mm. Such m eans for disconnection must be i ncorporation in the fixed wiring. . The waste battery shall be disposed p roperly. . The indoor unit installation height is at l east 2.5m.
3
WARNING!
Carefully read the following information in order to operate the airconditioner correctly.
Below are listed three kinds of Safety Cautions and Suggestions.
WARNING!
CAUTION!
Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
Incorrect operations may result in severe consequences of death or serious injuries.
INSTRUCTIONS: These information can ensure the correct operation of the machine.
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when needed.
If the conditioner is transferred to the new user, this manual should be as well transferred to the new user.
Otherwise the one will feel unpleasant or harm ones' health.
If any abnormal phenomena is found (e. g. smell of firing), please cut off the power supply immediately, and contact the dealer to find out the handling method.
In such case, to continue using the conditioner will damage the conditioner, and may cause electrical shock or fire hazard.
When need maintenance and repairment, call dealer to handle it.
Incorrect mainten­ance and repairment may cause water leak, electrical shock and fire hazard.
switch
off
Please let the dealer be responsible for installing
the conditioner.
Incorrect installation may cause water leak, elec-
trical shock and fire hazard.
Don't put fingers or any other things into the inlet/outlet and swing louver while the condi-
tioner is in operation.
Because the highspeed
fan is very dangerous
and may cause injuries.
Call the dealer to take measures to prevent the
refrigerant from leaking.
If conditioner is installed in a small room be sure
to take every measure in order to prevent suffoca-
tion accident even in case of refrigerant leakage.
When conditioner is deinstalled or reinstalled
dealer should be responsible for them.
Incorrect installation may cause water leaking,
electrical shock and fire hazard.
Don't blow the human body with the cooling air too long, and don't let the room tempera­ture decrease too low either.
Safety cautions
Cautions
4
CAUTIONS!
Conditioner should not be used for any other purpose other than airconditioning.
Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
Don't dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous which may harm human be­ings.
When air-conditioner is co-used with other heat-radiator the frequent replacement of room atmosphere should be required.
Inefficient venti­lation may cause suffocation.
After a long time use of air-conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
No goods or nobody is permitted to placed on or stand on outdoor unit.
The falling of goods and people may cause acci­dents.
Pets and plants should not be blowed directly in the air flow.
Otherwise will suffer damage.
Don't operate the air-con­ditioner with damp hands.
Otherwise will be shocked.
Only use correctly-typed fuse.
May not use wire or any other materials replacing fuse, other­wise may cause faults or fire accidents.
Don't place any burning unit in the air flow of air-conditioner, which may cause incomplete combustion.
No inflammable spray fluid should be permitted to be placed or used near to air­conditioner otherwise may cause fire accidents.
Air-conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Don't clean air-conditioner with water.
Otherwise may cause shock.
Otherwise the poisonous chemicals may settle in air-conditioner which harm the health of chemical-allergic people.
When use the fumigating insecticide don't open air-conditioner.
Cautions
5
WARNING !
CAUTION !
Please ask the dealer or specialist to install, never try by the users themselves. After the installation please
be sure of the following conditions.
Incorrect installation may cause water leaking, shock and fire hazard.
Please call dealer to install the air-conditioner.
Air-conditioner can't be installed in the envi­ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
Connect earthing wire.
Use discharge pipe correctly to ensure efficient discharge.
[Location]
[Wiring]
[Operating noise]
It easily cause electrical shock without circuit breaker.
Air-conditioner should be located in well-vented and easily-accessible place. Air-conditioner should not be located in the following places: (a) Places with machine oils or other oil vapours. (b) Seaside with high salt content in the air. (c) Near to hot spring with high content of sulfide gases. (d) Area with frequent fluctuation of voltage e.g. factory, etc. (e) In vehicles or ships. (f) Kitchen with heavy oil vapour or humidity. (g) Near to the machine emitting electric-magnetic waves. (h) Places with acid, alkali vapuor. TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created.
Earthing wire should not be con­nected to the gas pipe, water pipe, lightning rod or phone line, in­correct earthing may cause shock.
Incorrect pipe use may cause water leaking.
As required, take measures against heavy snow.
Air-conditioner should be equipped with special power supply wire.
Chose the following locations: (a) Capable of supporting air-conditioner weight, don't increase operating noise and vibration. (b) Hot vapour from outdoor unit outlet and ope­ rating noise don't disturb neighbour. No obstacles around the outdoor unit outlet.
Earthing
Installation
Cautions
Introduction to Spare Parts
AB182ACAEA
Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller)
Electrical Components Case
Air Inlet Grille
Air Filter (Inside of the Inlet Grille)
AB282ACAEA
AB42NACAEA
6
Drain Hose
Swing fender
Refrigerant pipe Cable line Earthing line
Air filter
Outlet
Suction grill
(located in the suction grill)
In cooling operation, to discharge the water from inside the room.
Discharge unit (built in)
(located in the outlet)
In cooling operation, to discharge the water from inside the room.
Discharge unit (built in)
Outlet Air filter
(located in the suction grill)
Suction grill
Refrigerant pipe Cable line Earthing line
Swing fender
(located in the outlet)
7
Maintenance
Clean the unit
Turn off the power supply switch
Do not touch with wet hand.
Do not use hot water or volatile liquid
The 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge. Generally the fixed blots are opened for inlet grille easily up and down as well cheaning the air filter.After open it,lower the inlet grille using remote controller, the maximum distance is 2.24m. Then turn the 1 rotated clamps 90 degree as shown in the figure, hold the air filter and nearly in the horizontal direction slightly pull it out.
Clean the air filter
Clean the air filter with water or vacuum cleaner. Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying.
Caution:
Do not clean the air filter with hot water over 40 C, otherwise may damage the filter.
Sweep the filter carefully.
Clean indoor (outdoor )unit
Clean with hot wet cloth and neutral detergent, then wipe with dry cloth.Do not use too hot water (over 40 C) which may result in fading and deforming. Do not use insecticide and chemical washing agent.
Fixing nolt
Fixing nolt
Fixing nolt
Rotary fixing clamp
Outward drawable filter
AB182ACAEA
For detailed information consult dealer.
NOTE:
ON
OFF