Haier AB422ACEAA, AB242AEEAA, AB262ACERA, AB262AEERA Operation & Installation Manual

Please read this operation manual before using the air conditioner.
No.0010577963
F
Operation & Installation Manual
CASSETTE TYPE AIR CONDITIONER
Please keep this manual carefully and safely.
AB122ACEAA AB182ACEAA AB242ACEAA AB242AEEAA AB282ACEAA AB282AEEAA AB362ACEAA AB422AEEAA AB482ACEAA AB482AEEAA AB602ACEAA
Contents
Cautions
...........................................................................................
Unit Appearance
................................................................................
Maintenance
...................................................................................
Trouble Shooting
..........................................................................
When Trouble Happens
..................................................................
Customer Need-to-know
......................................................................
Installation Procedure
....................................................................
1-5
6
7-10
11-12
13-15
16
17-26
Cautions
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
2
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 -5 24 26 -­ 20 27 15
14.5 -- -­ 7 24
-15
6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
For EAA series :
For ERA series:
4. The wiring method should be in line with the local wiring standard.
5. The power and connecting cable are self­provided, For series
122, AB182ACEAA, The
requirement of the power cable: H05RN-F 3G 2.5mm
2 .
The requirement of connecting cable: H05RN-F 3G 2.0mm
2
+H05RN-F 1x0.75mm
2.
For other series, refer to outdoor operation manual to select the power cable and connecting cable.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring.
7. The waste battery shall be disposed properly.
8. The indoor unit installation height is at least
2.5m.
9. The air breaker and the power switch should installed the conveniently reachable pleace for user.
10.For models
AB242AEEAA,AB242AEERA,
AB282AEEAA,AB282AEERA,
the emergency
switch on panel is not available.
Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
Cooling
Heating
Indoor
outdoor
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
3
WARNING!
Carefully read the following information in order to operate the airconditioner correctly.
Below are listed three kinds of Safety Cautions and Suggestions.
WARNING!
CAUTION!
Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
Incorrect operations may result in severe consequences of death or serious injuries.
INSTRUCTIONS: These information can ensure the correct operation of the machine.
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when needed.
If the conditioner is transferred to the new user, this manual should be as well transferred to the new user.
Safety cautions
Otherwise the one
will feel unpleasant
or harm ones' health.
If any abnormal phenomena is found (e. g.
smell of firing), please cut off the power
supply immediately, and contact the dealer
to find out the handling method.
In such case, to continue
using the conditioner will
damage the conditioner,
and may cause electrical
shock or fire hazard.
When need maintenance and repairment,
call dealer to handle it.
Incorrect mainten-
ance and repairment
may cause water
leak, electrical shock
and fire hazard.
switch
off
Please let the dealer be responsible for installing
the conditioner.
Incorrect installation may cause water leak, elec-
trical shock and fire hazard.
Don't put fingers or any other things into the
inlet/outlet and swing louver while the condi-
tioner is in operation.
Because the highspeed
fan is very dangerous
and may cause injuries.
Call the dealer to take measures to prevent the
refrigerant from leaking.
If conditioner is installed in a small room be sure
to take every measure in order to prevent suffoca-
tion accident even in case of refrigerant leakage.
When conditioner is deinstalled or reinstalled
dealer should be responsible for them.
Incorrect installation may cause water leaking,
electrical shock and fire hazard.
Don't blow the human body with the cooling
air too long, and don't let the room tempera-
ture decrease too low
either.
Cautions
4
CAUTIONS!
Conditioner should not be used for any other
purpose other than airconditioning.
Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
Don't dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous which may harm human be­ings.
When air-conditioner is co-used with other heat-radiator the frequent replacement of room atmosphere should be required.
Inefficient venti­lation may cause suffocation.
After a long time use of air-conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
No goods or nobody is permitted to placed on or stand on outdoor unit.
The falling of goods and people may cause acci­dents.
Pets and plants should not be blowed directly in the air flow.
Otherwise will suffer damage.
Don't operate the air-con­ditioner with damp hands.
Otherwise will be shocked.
Only use correctly-typed fuse.
May not use wire or any other materials replacing fuse, other­wise may cause faults or fire accidents.
Don't place any burning unit in the air flow of air-conditioner, which may cause incomplete combustion.
No inflammable spray fluid should be permitted to be placed or used near to air­conditioner otherwise may cause fire accidents.
Air-conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Don't clean air-conditioner with water.
Otherwise may cause shock.
Otherwise the poisonous chemicals may settle in air-conditioner which harm the health of chemical-allergic people.
When use the fumigating insecticide don't open air-conditioner.
Cautions
5
WARNING !
CAUTION !
Please ask the dealer or specialist to install, never try by the users themselves. After the installation please
be sure of the following conditions.
Incorrect installation may cause water leaking, shock and fire hazard.
Please call dealer to install the air-conditioner.
Air-conditioner can't be installed in the envi­ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
Connect earthing wire.
Use discharge pipe correctly to ensure efficient discharge.
[Location]
[Wiring]
[Operating noise]
It easily cause electrical shock without circuit breaker.
Air-conditioner should be located in well-vented and easily-accessible place. Air-conditioner should not be located in the following places: (a) Places with machine oils or other oil vapours. (b) Seaside with high salt content in the air. (c) Near to hot spring with high content of sulfide gases. (d) Area with frequent fluctuation of voltage e.g. factory, etc. (e) In vehicles or ships. (f) Kitchen with heavy oil vapour or humidity. (g) Near to the machine emitting electric-magnetic waves. (h) Places with acid, alkali vapuor. TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created.
Earthing wire should not be con­nected to the gas pipe, water pipe, lightning rod or phone line, in­correct earthing may cause shock.
Incorrect pipe use may cause water leaking.
As required, take measures against heavy snow.
Air-conditioner should be equipped with special power supply wire.
Chose the following locations: (a) Capable of supporting air-conditioner weight, don't increase operating noise and vibration. (b) Hot vapour from outdoor unit outlet and ope­ rating noise don't disturb neighbour. No obstacles around the outdoor unit outlet.
Earthing
Installation
Cautions
Unit Appearance
6
AB362ACERA - AB482ACEAA - AB602ACEAA AB602ACERA
AB282AEERA - AB362ACEAA -AB362AEERA AB422AEEAA - AB482AEEAA - AB482AEERA
AB122ACEAA - AB122ACERA - AB182ACEAA AB182ACERA
AB242ACEAA - AB242ACERA - AB282ACEAA
AB242AEEAA - AB242AEERA - AB282AEEAA
7
Maintenance
Clean the unit
Turn off the power supply switch
Do not touch with wet hand.
Do not use hot water or volatile liquid
For detailed information consult dealer.
NOTE:
For series 122, 182 and AB242AEEAA, AB242AEERA, AB282AEEAA, AB282AEERA, AB362ACEAA, AB362AEERA, AB422AEEAA, AB482AEERA, AB482AEEAA
Press the embeding switch according to the direction of the arrowhead.
Get the air inlet grille.
Manual: Please don't tear down the air filter, or it may lead to trouble. If the environment where the air-con works is full of dust, the air filter should be wash more times than ever ( it is usually twice a week).
Air filter washing
1.Get the air inlet grille Look at picture 1, press the two embeding switch vertically to make it close to the side grille, then
raise it for about 45
o
to take the air inlet grille down.
2. Tear down the air filter (Picture 2)
Press the outer brim of the air inlet grille with your thumb, at the same time, pull out the bottom rim of the filter net slightly with your forefinger, so the filter net can part from the embeding switch for us to get it easily.
Picture 1
Picture 2
The bottom rim of the filter net
The brim of air inlet grille
PS: the pictures above are only models, pls obey the real machinery.
ON
OFF
Maintenance
8
For series 602 and AB242ACEAA, AB242ACERA, AB282ACEAA, AB362ACERA,
AB482ACEAA
Clean the air filter
Instructions :
1. Open air inlet grille
2.Dismantle the air filter
3. Clean
When not for cleaning, do not dismantle the air filter, otherwise it may cause trouble. When the air conditioner is used in a dusty environment, the air filter should be cleaned more often (generally once every two weeks).
Pull the two handles at the same time, slowly draw them out. (when closing it, the procedure is reversed.)
Pull the two side handles at the back of the air inlet grille, lift the air filter to dismantle it.
Use cleaner or water to clean to remove dust.
(A) Use cleaner to remove dust.
(B) When the dust is too much, use soft brush and neutral detergent.
(C) Throw the water off, then put it in the shadow for airing.
4. Install air filter
5. Close air inlet grille
(1).Put the air filter into those extruding parts at the top of the air inlet grille.
(2).Draw the handles at the back of the air inlet grille inwards to fix the air filter.
Referring to procedure 1.
Open
Open and remove
Notice
Do not use the hot water over 50 C to clean to avoid discoloration or deformation. Do not dry the unit on fire, the filter may be burnt.